Abstract: Prestressed concrete is used a lot in infrastructures such as roads or bridges. However, poor grout filling and PC steel corrosion are currently major issues of prestressed concrete structures. One of the problems with nondestructive corrosion detection of PC steel is a plastic pipe which covers PC steel. The insulative property of pipe makes a nondestructive diagnosis difficult; therefore a practical technology to detect these defects is necessary for the maintenance of infrastructures. The goal of the research is a development of an electrochemical technique which enables to detect internal defects from the surface of prestressed concrete nondestructively. Ideally, the measurements should be conducted from the surface of structural members to diagnose non-destructively. In the present experiment, a prestressed concrete member is simplified as a layered specimen to simulate a current path between an input and an output electrode on a member surface. The specimens which are layered by mortar and the prestressed concrete constitution materials (steel, polyethylene, stainless steel, or galvanized steel plates) were provided to the alternating current impedance measurement. The magnitude of an applied electric field was 0.01-volt or 1-volt, and the frequency range was from 106 Hz to 10-2 Hz. The frequency spectrums of impedance, which relate to charge reactions activated by an electric field, were measured to clarify the effects of the material configurations or the properties. In the civil engineering field, the Nyquist diagram is popular to analyze impedance and it is a good way to grasp electric relaxation using a shape of the plot. However, it is slightly not suitable to figure out an influence of a measurement frequency which is reciprocal of reaction time. Hence, Bode diagram is also applied to describe charge reactions in the present paper. From the experiment results, the alternating current impedance method looks to be applicable to the insulative material measurement and eventually prestressed concrete diagnosis. At the same time, the frequency spectrums of impedance show the difference of the material configuration. This is because the charge mobility reflects the variety of substances and also the measuring frequency of the electric field determines migration length of charges which are under the influence of the electric field. However, it could not distinguish the differences of the material thickness and is inferred the difficulties of prestressed concrete diagnosis to identify the amount of an air void or a layer of corrosion product by the technique.
Abstract: National bridge inventory in Korea shows that the number of old prestressed concrete (PSC) bridgeover 30 years of service life is rapidly increasing. Recently tendon corrosion is one of the most critical issues in the maintenance of PSC bridges. In this paper, mechanical properties of corroded strands, which were removed from old bridges, were evaluated using tensile test. In the result, the equations to express the mechanical behavior of corroded strand were derived and compared to existing equation. For the decision of tendon replacement, it is necessary to evaluate the effect of corrosion level on strength and ductility of the structure. Considerations on analysis of PSC girders were introduced, and decision making on tendon replacement was also proposed.
Abstract: Recently, the use of high-strength materials is increasing as the construction of large structures and high-rise structures increases. This paper presents an analysis of the shear behavior of prestressed concrete members with various types of materials by simulating a finite element (FE) analysis. The analytical results indicated that the shear strength and shear failure mode were strongly influenced by not only the shear reinforcement ratio but also the yield strength of shear reinforcement and the compressive strength of concrete. Though the yield strength of shear reinforcement increased the shear strength of prestressed concrete members, there was a limit to the increase in strength because of the change of shear failure modes. According to the results of FE analysis on various parameters, the maximum yield strength of the steel stirrup that can be applied to prestressed concrete members was about 860 MPa.
Abstract: At certain depths during large diameter displacement
pile driving, rebound well over 0.25 inches was experienced,
followed by a small permanent-set during each hammer blow. High
pile rebound (HPR) soils may stop the pile driving and results in a
limited pile capacity. In some cases, rebound leads to pile damage,
delaying the construction project, and the requiring foundations
redesign. HPR was evaluated at seven Florida sites, during driving of
square precast, prestressed concrete piles driven into saturated, fine
silty to clayey sands and sandy clays. Pile Driving Analyzer (PDA)
deflection versus time data recorded during installation, was used to
develop correlations between cone penetrometer (CPT) pore-water
pressures, pile displacements and rebound. At five sites where piles
experienced excessive HPR with minimal set, the pore pressure
yielded very high positive values of greater than 20 tsf. However, at
the site where the pile rebounded, followed by an acceptable
permanent-set, the measured pore pressure ranged between 5 and 20
tsf. The pore pressure exhibited values of less than 5 tsf at the site
where no rebound was noticed. In summary, direct correlations
between CPTu pore pressure and rebound were produced, allowing
identification of soils that produce HPR.
Abstract: Paper presents a study about dynamic effects obtained
from the dynamic load testing of the city highway bridges in Latvia
carried out from 2005 to 2012. 9 prestressed concrete bridges and 4
composite bridges were considered. 11 of 13 bridges were designed
according to the Eurocodes but two according to the previous
structural codes used in Latvia (SNIP 2.05.03-84). The dynamic
properties of the bridges were obtained by heavy vehicle passing the
bridge roadway with different driving speeds and with or without
even pavement. The obtained values of the Dynamic amplification
factor (DAF) and the bridge natural frequency were analyzed and
compared to the values of built-in traffic load models provided in
Eurocode 1. The actual DAF values for even bridge pavement in the
most cases are smaller than the value adopted in Eurocode 1. Vehicle
speed for uneven pavements significantly influence Dynamic
amplification factor values.
Abstract: The objective of this research is to investigate the
advantages of using large-diameter 0.7 inch prestressing strands in
pretention applications. The advantages of large-diameter strands are
mainly beneficial in the heavy construction applications. Bridges and
tunnels are subjected to a higher daily traffic with an exponential
increase in trucks ultimate weight, which raise the demand for higher
structural capacity of bridges and tunnels. In this research, precast
prestressed I-girders were considered as a case study. Flexure
capacities of girders fabricated using 0.7 inch strands and different
concrete strengths were calculated and compared to capacities of 0.6
inch strands girders fabricated using equivalent concrete strength.
The effect of bridge deck concrete strength on composite deck-girder
section capacity was investigated due to its possible effect on final
section capacity. Finally, a comparison was made to compare the
bridge cross-section of girders designed using regular 0.6 inch strands
and the large-diameter 0.7 inch. The research findings showed that
structural advantages of 0.7 inch strands allow for using fewer bridge
girders, reduced material quantity, and light-weight members. The
structural advantages of 0.7 inch strands are maximized when high
strength concrete (HSC) are used in girder fabrication, and concrete
of minimum 5ksi compressive strength is used in pouring bridge
decks. The use of 0.7 inch strands in bridge industry can partially
contribute to the improvement of bridge conditions, minimize
construction cost, and reduce the construction duration of the project.
Abstract: The National Bridge Inventory (NBI) includes more
than 600,000 bridges within the United States of America.
Prestressed concrete girder bridges represent one of the most widely
used bridge systems. The majority of these girder bridges were
constructed using 0.5 and 0.6 inch diameter strands. The main
impediments to using larger strand diameters are: 1) lack of prestress
bed capacities, 2) lack of structural knowledge regarding the transfer
and development length of larger strands, and 3) the possibility of
developing wider end zone cracks upon strand release.
This paper presents a study about using 0.7 inch strands in girder
fabrication. Transfer and development length were evaluated, and
girders were fabricated using 0.7 inch strands at different spacings.
Results showed that 0.7 inch strands can be used at 2.0 inch spacing
without violating the AASHTO LRFD Specifications, while attaining
superior performance in shear and flexure.
Abstract: The main objectives of this study are to inspect and
identify any damage of jaimusi highway prestressed concrete bridge
after repair and strengthening of damaged structural members and to
evaluate the performance of the bridge structural members by
adopting static load test. Inspection program after repair and
strengthening includes identifying and evaluating the structural
members of bridge such as T-shape cantilever structure, hanging
beams, corbels, external tendons, anchor beams, sticking steel plate,
and piers. The results of inspection show that the overall state of the
bridge structural member after repair and strengthening is good. The
results of rebound test of concrete strength show that the average
strength of concrete is 46.31Mpa. Whereas, the average value of
concrete strength of anchor beam is 49.82Mpa. According to the
results of static load test, the experimental values are less than
theoretical values of internal forces, deflection, and strain, indicating
that the stiffness of the experimental structure, overall deformation
and integrity satisfy the designed standard and the working
performance is good, and the undertaking capacity has a certain
surplus. There is not visible change in the length and width of cracks
and there are not new cracks under experimental load.
Abstract: Existing underground pipe jacking methods use a
reinforcing rod in a steel tube to obtain structural stiffness. However,
some problems such as inconvenience of works and expensive
materials resulted from limited working space and reinforcing works
are existed. To resolve these problems, a new pipe jacking method,
namely PST (Prestressed Segment Tunnel) method, was developed
which used joint to connect the steel segment and form erection
structure. For evaluating the flexural capacity of the PST method
structure, a experimental test was conducted. The parameters
considered in the test were span-to-depth ratio of segment, diameter of
steel tube at the corner, prestressing force, and welding of joint. The
flexural behaviours with the effect of load capacity in serviceability
state according to different parameters were examined.. The frame
with long segments could increase flexural stiffness and the specimen
with large diameter of concave corner showed excellent resistance
ability to the negative moment. In addition, welding of joints increased
the flexural capacity.
Abstract: It is necessary to evaluate the bridges conditions and
strengthen bridges or parts of them. The reinforcement necessary due
to some reasons can be summarized as: First, a changing in use of
bridge could produce internal forces in a part of structural which
exceed the existing cross-sectional capacity. Second, bridges may
also need reinforcement because damage due to external factors
which reduced the cross-sectional resistance to external loads. One of
other factors could listed here its misdesign in some details, like
safety of bridge or part of its.This article identify the design demands
of Qing Shan bridge located in is in Heilongjiang Province He gang -
Nen Jiang Road 303 provincial highway, Wudalianchi area, China, is
an important bridge in the urban areas. The investigation program
was include the observation and evaluate the damage in T- section
concrete beams , prestressed concrete box girder bridges section in
additional evaluate the whole state of bridge includes the pier ,
abutments , bridge decks, wings , bearing and capping beam, joints,
........etc. The test results show that the bridges in general structural
condition are good. T beam span No 10 were observed, crack
extended upward along the ribbed T beam, and continue to the T
beam flange. Crack width varying between 0.1mm to 0.4mm, the
maximum about 0.4mm. The bridge needs to be improved flexural
bending strength especially at for T beam section.
Abstract: Since prestressed concrete members rely on the tensile
strength of the prestressing strands to resist loads, loss of even few
them could result catastrophic. Therefore, it is important to measure
present residual prestress force. Although there are some techniques
for obtaining present prestress force, some problems still remain. One
method is to install load cell in front of anchor head but this may
increase cost. Load cell is a transducer using the elastic material
property. Anchor head is also an elastic material and this might result
in monitoring monitor present prestress force. Features of fiber optic
sensor such as small size, great sensitivity, high durability can assign
sensing function to anchor head. This paper presents the concept of
smart anchor head which acts as load cell and experiment for the
applicability of it. Test results showed the smart anchor head worked
good and strong linear relationship between load and response.