Abstract: Wheelchair users spend long hours in a sitting position, and selecting the right cushion is highly critical in preventing pressure ulcers in that demographic. Pressure Mapping Systems (PMS) are typically used in clinical settings by therapists to identify the sitting profile and pressure points in the sitting area to select the cushion that fits the best for the users. A PMS is a flexible mat composed of arrays of distributed networks of pressure sensors. The output of the PMS systems is a color-coded image that shows the intensity of the pressure concentration. Therapists use the PMS images to compare different cushions fit for each user. This process is highly subjective and requires good visual memory for the best outcome. This paper aims to develop an image processing technique to analyze the images of PMS and provide an objective measure to assess the cushions based on their pressure distribution mappings. In this paper, we first reviewed the skeletal anatomy of the human sitting area and its relation to the PMS image. This knowledge is then used to identify the important features that must be considered in image processing. We then developed an algorithm based on those features to analyze the images and rank them according to their fit to the user's needs.
Abstract: A Gerotor pump is composed of an external and internal gear with conjugate cycloidal profiles. From suction to delivery ports, the fluid is transported inside cavities formed by teeth and driven by the shaft. From a geometric and conceptional side it is worth to note that the internal gear has one tooth less than the external one. Simcenter Amesim v.16 includes a new submodel for modelling the hydraulic Gerotor pumps behavior (THCDGP0). This submodel considers leakages between teeth tips using Poiseuille and Couette flows contributions. From the 3D CAD model of the studied pump, the “CAD import” tool takes out the main geometrical characteristics and the submodel THCDGP0 computes the evolution of each cavity volume and their relative position according to the suction or delivery areas. This module, based on international publications, presents robust results up to 6 000 rpm for pressure greater than atmospheric level. For higher rotational speeds or lower pressures, oil aeration and cavitation effects are significant and highly drop the pump’s performance. The liquid used in hydraulic systems always contains some gas, which is dissolved in the liquid at high pressure and tends to be released in a free form (i.e. undissolved as bubbles) when pressure drops. In addition to gas release and dissolution, the liquid itself may vaporize due to cavitation. To model the relative density of the equivalent fluid, modified Henry’s law is applied in Simcenter Amesim v.16 to predict the fraction of undissolved gas or vapor. Three parietal pressure sensors have been set up upstream from the pump to estimate the sound speed in the oil. Analytical models have been compared with the experimental sound speed to estimate the occluded gas content. Simcenter Amesim v.16 model was supplied by these previous analyses marks which have successfully improved the simulations results up to 14 000 rpm. This work provides a sound foundation for designing the next Gerotor pump generation reaching high rotation range more than 25 000 rpm. This improved module results will be compared to tests on this new pump demonstrator.
Abstract: The average American worker sits for thirteen hours a day, often with poor posture and infrequent breaks, which can lead to health issues and back problems. The Smart Cushion was created to alert individuals of their poor postures, and may potentially alleviate back problems and correct poor posture. The Smart Cushion is a portable, rectangular, foam cushion, with five strategically placed pressure sensors, that utilizes an Arduino Uno circuit board and specifically designed software, allowing it to collect data from the five pressure sensors and store the data on an SD card. The data is then compiled into graphs and compared to controlled postures. Before volunteers sat on the cushion, their levels of back pain were recorded on a scale from 1-10. Data was recorded for an hour during sitting, and then a new, corrected posture was suggested. After using the suggested posture for an hour, the volunteers described their level of discomfort on a scale from 1-10. Different patterns of sitting postures were generated that were able to serve as early warnings of potential back problems. By using the Smart Cushion, the areas where different volunteers were applying the most pressure while sitting could be identified, and the sitting postures could be corrected. Further studies regarding the relationships between posture and specific regions of the body are necessary to better understand the origins of back pain; however, the Smart Cushion is sufficient for correcting sitting posture and preventing the development of additional back pain.
Abstract: The understanding of generation and collapse of acoustic cavitation bubbles are prerequisites for application of cavitation erosion. Microbubbles generated due to rapid fluctuation of pressure induced by propagation of ultrasonic wave lead to formation of high velocity microjets and or shock waves upon collapse. Due to vast application of ultrasonic, it is important to characterize and understand cavitation collapse pressure under the radiating surface at different conditions. A comparative investigation is carried out to determine impact load and dynamic pressure distribution exerted upon bubble collapse using thin film pressure sensors. Measurements were recorded at different input conditions such as amplitude, stand-off distance, insertion depth of the horn inside the liquid and pulse on-off time of acoustic vibrations. Impact force of 2.97 N is recorded at amplitude of 108 μm and stand-off distance of 1 mm from the sensor film, whereas impulsive force as low as 0.4 N is recorded at amplitude of 12 μm and stand-off distance of 5 mm from the sensor film. The results drawn from the investigation indicated that variety of impact loads can be achieved by controlling generation and collapse of bubbles, making it suitable to use for numerous application.
Abstract: The paper describes conceptual design, control strategies, and partial simulation for a new fully autonomous lower limb wearable exoskeleton system for human motion enhancement that can support its weight and increase strength and endurance. Various problems still remain to be solved where the most important is the creation of a power and cost efficient system that will allow an exoskeleton to operate for extended period without batteries being frequently recharged. The designed exoskeleton is enabling to decouple the weight/mass carrying function of the system from the forward motion function which reduces the power and size of propulsion motors and thus the overall weight, cost of the system. The decoupling takes place by blocking the motion at knee joint by placing passive air cylinder across the joint. The cylinder is actuated when the knee angle has reached the minimum allowed value to bend. The value of the minimum bending angle depends on usual walk style of the subject. The mechanism of the exoskeleton features a seat to rest the subject’s body weight at the moment of blocking the knee joint motion. The mechanical structure of each leg has six degrees of freedom: four at the hip, one at the knee, and one at the ankle. Exoskeleton legs are attached to subject legs by using flexible cuffs. The operation of all actuators depends on the amount of pressure felt by the feet pressure sensors and knee angle sensor. The sensor readings depend on actual posture of the subject and can be classified in three distinct cases: subject stands on one leg, subject stands still on both legs and subject stands on both legs but transit its weight from one leg to other. This exoskeleton is power efficient because electrical motors are smaller in size and did not participate in supporting the weight like in all other existing exoskeleton designs.
Abstract: The MEMS pressure sensor has been introduced and
presented in this paper. The types of pressure sensor and its theory of
operation are also included. The latest MEMS technology, the
fabrication processes of pressure sensor are explored and discussed.
Besides, various device applications of pressure sensor such as tire
pressure-monitoring system, diesel particulate filter and others are
explained. Due to further miniaturization of the device nowadays, the
pressure sensor with nanotechnology (NEMS) is also reviewed. The
NEMS pressure sensor is expected to have better performance as well
as lower in its cost. It has gained an excellent popularity in many
applications.
Abstract: A game for training of breath (TRABR) for continuous
monitoring of pulmonary ventilation during the patients’ therapy
focuses especially on monitoring of their ventilation processes. It is
necessary to detect, monitor and differentiate abdominal and thoracic
breathing during the therapy. It is a fun form of rehabilitation where
the patient plays and also practicing isolated breathing. Finally the
game to practice breath was designed to evaluate whether the patient
uses two types of breathing or not.
Abstract: This paper presents a resonant-based read-out circuit for capacitive pressure sensors. The proposed read-out circuit consists of an LC oscillator and a counter. The circuit detects the capacitance changes of a capacitive pressure sensor by means of frequency shifts from its nominal operation frequency. The proposed circuit is designed in 0.18m CMOS with an estimated power consumption of 43.1mW. Simulation results show that the circuit has a capacitive resolution of 8.06kHz/fF, which enables it for high resolution pressure detection.
Abstract: Obstructive sleep apnea in patients, between 70 and 80
percent, can be cured with just a posture correcting. The most import
thing to do this is detection of obstructive sleep apnea. Detection of
obstructive sleep apnea can be performed through heart rate variability
analysis using power spectrum density analysis. After HRV analysis
we needed to know the current position information for correcting the
position. The pressure sensors of the array type were used to obtain
position information. These sensors can obtain information from the
experimenter about position. In addition, air cylinder corrected the
position of the experimenter by lifting the bed. The experimenter can
be changed position without breaking during sleep by the system.
Polysomnograph recording were obtained from 10 patients. The
results of HRV analysis were that NLF and LF/HF ratio increased,
while NHF decreased during OSA. Position change had to be done the
periods.
Abstract: This paper describes a low-power second-order filter
for a continuous-time chopper stabilized capacitive sensor interface,
integrated with a fully differential post-CMOS surface-micromachined
MEMS pressure sensor. The circuit uses a single-ended
folded-cascode operational amplifier and two GM-C filters connected
in cascade. The circuit is realized in a 0.18 μm CMOS process and
offers differential to single-ended conversion. The novelty of the
scheme is the cascade of two GM-C filters to achieve a second-order
filter while minimizing power dissipation. The simulated filter cutoff
frequency is 1.14 kHz at common-mode voltage 1.65 V,
operating from a 3.3 V supply while dissipating 172μW of power.
The filter achieves an operating range of 1V for an output load of
1MOhm and 10pF.
Abstract: Pressure wave velocity in a hydraulic system was
determined using piezo pressure sensors without removing fluid from
the system. The measurements were carried out in a low pressure
range (0.2 – 6 bar) and the results were compared with the results of
other studies. This method is not as accurate as measurement with
separate measurement equipment, but the fluid is in the actual
machine the whole time and the effect of air is taken into
consideration if air is present in the system. The amount of air is
estimated by calculations and comparisons between other studies.
This measurement equipment can also be installed in an existing
machine and it can be programmed so that it measures in real time.
Thus, it could be used e.g. to control dampers.
Abstract: The aim of study was to evaluate pressure distribution characteristics of the elastic textile bandages using two instrumental techniques: a prototype Instrument and a load Transference. The prototype instrument which simulates shape of real leg has pressure sensors which measure bandage pressure. Using this instrument, the results show that elastic textile bandages presents different pressure distribution characteristics and none produces a uniform distribution around lower limb.
The load transference test procedure is used to determine whether a relationship exists between elastic textile bandage structure and pressure distribution characteristics. The test procedure assesses degree of load, directly transferred through a textile when loads series are applied to bandaging surface. A range of weave fabrics was produced using needle weaving machine and a sewing technique. A textile bandage was developed with optimal characteristics far superior pressure distribution than other bandages. From results, we find that theoretical pressure is not consistent exactly with practical pressure. It is important in this study to make a practical application for specialized nurses in order to verify the results and draw useful conclusions for predicting the use of this type of elastic band.
Abstract: In this paper the development of a heat exchanger as a
pilot plant for educational purpose is discussed and the use of neural
network for controlling the process is being presented. The aim of the
study is to highlight the need of a specific Pseudo Random Binary
Sequence (PRBS) to excite a process under control. As the neural
network is a data driven technique, the method for data generation
plays an important role. In light of this a careful experimentation
procedure for data generation was crucial task. Heat exchange is a
complex process, which has a capacity and a time lag as process
elements. The proposed system is a typical pipe-in- pipe type heat
exchanger. The complexity of the system demands careful selection,
proper installation and commissioning. The temperature, flow, and
pressure sensors play a vital role in the control performance. The
final control element used is a pneumatically operated control valve.
While carrying out the experimentation on heat exchanger a welldrafted
procedure is followed giving utmost attention towards safety
of the system. The results obtained are encouraging and revealing
the fact that if the process details are known completely as far as
process parameters are concerned and utilities are well stabilized then
feedback systems are suitable, whereas neural network control
paradigm is useful for the processes with nonlinearity and less
knowledge about process. The implementation of NN control
reinforces the concepts of process control and NN control paradigm.
The result also underlined the importance of excitation signal
typically for that process. Data acquisition, processing, and
presentation in a typical format are the most important parameters
while validating the results.
Abstract: Due to their high power-to-weight ratio and low cost, pneumatic actuators are attractive for robotics and automation applications; however, achieving fast and accurate control of their position have been known as a complex control problem. The paper presents a methodology for obtaining controllers that achieve high position accuracy and preserve the closed-loop characteristics over a broad operating range. Experimentation with a number of conventional (or "classical") three-term controllers shows that, as repeated operations accumulate, the characteristics of the pneumatic actuator change requiring frequent re-tuning of the controller parameters (PID gains). Furthermore, three-term controllers are found to perform poorly in recovering the closed-loop system after the application of load or other external disturbances. The key reason for these problems lies in the non-linear exchange of energy inside the cylinder relating, in particular, to the complex friction forces that develop on the piston-wall interface. In order to overcome this problem but still remain within the boundaries of classical control methods, we designed an auto selective classicaql controller so that the system performance would benefit from all three control gains (KP, Kd, Ki) according to system requirements and the characteristics of each type of controller. This challenging experimentation took place for consistent performance in the face of modelling imprecision and disturbances. In the work presented, a selective PID controller is presented for an experimental rig comprising an air cylinder driven by a variable-opening pneumatic valve and equipped with position and pressure sensors. The paper reports on tests carried out to investigate the capability of this specific controller to achieve consistent control performance under, repeated operations and other changes in operating conditions.