Abstract: Optimization and control of reactive power
distribution in the power systems leads to the better operation of the
reactive power resources. Reactive power control reduces
considerably the power losses and effective loads and improves the
power factor of the power systems. Another important reason of the
reactive power control is improving the voltage profile of the power
system. In this paper, voltage and reactive power control using
Neural Network techniques have been applied to the 33 shines-
Tehran Electric Company. In this suggested ANN, the voltages of PQ
shines have been considered as the input of the ANN. Also, the
generators voltages, tap transformers and shunt compensators have
been considered as the output of ANN. Results of this techniques
have been compared with the Linear Programming. Minimization of
the transmission line power losses has been considered as the
objective function of the linear programming technique. The
comparison of the results of the ANN technique with the LP shows
that the ANN technique improves the precision and reduces the
computation time. ANN technique also has a simple structure and
this causes to use the operator experience.
Abstract: In this paper, half bridge DC-DC converters with
transformer isolation presented in the literature are analyzed for highcurrent
and low-voltage applications under the same operation
conditions, and compared in terms of losses and efficiency. The
conventional and improved half-bridge DC-DC converters are
simulated, and current and voltage waveforms are obtained for input
voltage Vdc=500V, output current IO=450A, output voltage VO=38V
and switching frequency fS=20kHz. IGBTs are used as power
semiconductor switches. The power losses of the semiconductor
devices are calculated from current and voltage waveforms. From
simulation results, it is seen that the capacitor switched half bridge
converter has the best efficiency value, and can be preferred at high
power and high frequency applications.
Abstract: Optical 1x12 fused-taper-twisted polymer optical fiber (POF) couplers has been fabricated by a perform technique. Characterization of the coupler which proposed to be used in passive night vision application to tracking a blind sport area was reported. During the development process of fused-taper-twisted POF couplers was carried out, red LED fully utilized to be injected into the couplers to test the quality of fabricated couplers. Some characterization parameters, such as optical output power, POFs attenuation characteristics and power losses on the network were observed. The maximum output power efficiency of the coupler is about 40%, but it can be improved gradually through experience and practice.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. These methods can be
used to assess the transmission prices, but also to recover the
transmission fixed cost. In this paper is presented the influence of the
modification of commons structure has on the specific price of transfer
and on active power losses. The authors propose a power losses
allocation method, based on Kirschen-s method. The system operator
must make use of a few basic principles about allocation. The only
necessary information is the power flows on system branches and the
modifications applied to power system buses. In order to illustrate this
method, the 25-bus test system is used, elaborated within the Electrical
Power Engineering Department, from Timisoara, Romania.
Abstract: This paper proposes a new methodology for the
optimal allocation and sizing of Embedded Generation (EG)
employing Real Coded Genetic Algorithm (RCGA) to minimize the
total power losses and to improve voltage profiles in the radial
distribution networks. RCGA is a method that uses continuous
floating numbers as representation which is different from
conventional binary numbers. The RCGA is used as solution tool,
which can determine the optimal location and size of EG in radial
system simultaneously. This method is developed in MATLAB. The
effect of EG units- installation and their sizing to the distribution
networks are demonstrated using 24 bus system.
Abstract: Importance of environmental efficiency of electric power industry stems from high demand for energy combined with global warming concerns. It is especially essential for the world largest economies like that of the United States. The paper introduces a Data Envelopment Analysis (DEA) model of environmental efficiency using indicators of fossil fuels utilization, emissions rate, and electric power losses. Using DEA is advantageous in this situation over other approaches due to its nonparametric nature. The paper analyzes data for the period of 1990 - 2006 by comparing actual yearly levels in each dimension with the best values of partial indicators for the period. As positive factors of efficiency, tendency to the decline in emissions rates starting 2000, and in electric power losses starting 2004 may be mentioned together with increasing trend of fuel utilization starting 1999. As a result, dynamics of environmental efficiency is positive starting 2002. The main concern is the decline in fossil fuels utilization in 2006. This negative change should be reversed to comply with ecological and economic requirements.
Abstract: To minimize power losses, it is important to
determine the location and size of local generators to be placed in
unbalanced power distribution systems. On account of some inherent
features of unbalanced distribution systems, such as radial structure,
large number of nodes, a wide range of X/R ratios, the conventional
techniques developed for the transmission systems generally fail on
the determination of optimum size and location of distributed
generators (DGs). This paper presents a simple method for
investigating the problem of contemporaneously choosing best
location and size of DG in three-phase unbalanced radial distribution
system (URDS) for power loss minimization and to improve the
voltage profile of the system. Best location of the DG is determined
by using voltage index analysis and size of DG is computed by
variational technique algorithm according to available standard size
of DGs. This paper presents the results of simulations for 25-bus and
IEEE 37- bus Unbalanced Radial Distribution system.
Abstract: Recently, distributed generation technologies have received much attention for the potential energy savings and reliability assurances that might be achieved as a result of their widespread adoption. Fueling the attention have been the possibilities of international agreements to reduce greenhouse gas emissions, electricity sector restructuring, high power reliability requirements for certain activities, and concern about easing transmission and distribution capacity bottlenecks and congestion. So it is necessary that impact of these kinds of generators on distribution feeder reconfiguration would be investigated. This paper presents an approach for distribution reconfiguration considering Distributed Generators (DGs). The objective function is summation of electrical power losses A Tabu search optimization is used to solve the optimal operation problem. The approach is tested on a real distribution feeder.
Abstract: Voltage collapse is instability of heavily loaded electric
power systems that cause to declining voltages and blackout. Power
systems are predicated to become more heavily loaded in the future
decade as the demand for electric power rises while economic and
environmental concerns limit the construction of new transmission
and generation capacity. Heavily loaded power systems are closer to
their stability limits and voltage collapse blackouts will occur if
suitable monitoring and control measures are not taken. To control
transmission lines, it can be used from FACTS devices.
In this paper Harmony search algorithm (HSA) and Genetic
Algorithm (GA) have applied to determine optimal location of
FACTS devices in a power system to improve power system stability.
Three types of FACTS devices (TCPAT, UPFS, and SVC) have been
introduced. Bus under voltage has been solved by controlling reactive
power of shunt compensator. Also a combined series-shunt
compensators has been also used to control transmission power flow
and bus voltage simultaneously.
Different scenarios have been considered. First TCPAT, UPFS, and
SVC are placed solely in transmission lines and indices have been
calculated. Then two types of above controller try to improve
parameters randomly. The last scenario tries to make better voltage
stability index and losses by implementation of three types controller
simultaneously. These scenarios are executed on typical 34-bus test
system and yields efficiency in improvement of voltage profile and
reduction of power losses; it also may permit an increase in power
transfer capacity, maximum loading, and voltage stability margin.
Abstract: Design and evaluation of reciprocating compressors
should include a pulsation study. The object is to ensure that
predicted pulsation levels meet guidelines to limit vibration, shaking
forces, noise, associated pressure drops, horsepower losses and
fabrication cost and time to acceptable levels. This paper explains
procedures and recommendations to select and size pulsation
suppression devices to obtain optimum arrangement in terms of
pulsation, vibration, shaking forces, performance, reliability, safety,
operation, maintenance and commercial conditions. Model and
advanced formulations for pulsation study are presented. The effect
of the full fluid dynamic model on the prediction of pulsation waves
and resulting frequency spectrum distributions are discussed.
Advanced and optimum methods of controlling pulsations are
highlighted. Useful recommendations and guidelines for pulsation
control, piping pulsation analysis, pulsation vessel design, shaking
forces, low pressure drop orifices, pulsation study report and devices
to mitigate pulsation and shaking problems are discussed.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.
Abstract: Losses reduction initiatives in distribution systems
have been activated due to the increasing cost of supplying
electricity, the shortage in fuel with ever-increasing cost to produce
more power, and the global warming concerns. These initiatives have
been introduced to the utilities in shape of incentives and penalties.
Recently, the electricity distribution companies in Oman have been
incentivized to reduce the distribution technical and non-technical
losses with an equal annual reduction rate for 6 years. In this paper,
different techniques for losses reduction in Mazoon Electricity
Company (MZEC) are addressed. In this company, high numbers of
substation and feeders were found to be non-compliant with the
Distribution System Security Standard (DSSS). Therefore, 33
projects have been suggested to bring non-complying 29 substations
and 28 feeders to meet the planed criteria and to comply with the
DSSS. The largest part of MZEC-s network (South Batinah region)
was modeled by ETAP software package. The model has been
extended to implement the proposed projects and to examine their
effects on losses reduction. Simulation results have shown that the
implementation of these projects leads to a significant improvement
in voltage profile, and reduction in the active and the reactive power
losses. Finally, the economical analysis has revealed that the
implementation of the proposed projects in MZEC leads to an annual
saving of about US$ 5 million.
Abstract: The paper presents coupled electromagnetic and
thermal field analysis of busbar system (of rectangular cross-section
geometry) submitted to short circuit conditions. The laboratory model
was validated against both analytical solution and experimental
observations. The considered problem required the computation of
the detailed distribution of the power losses and the heat transfer
modes. In this electromagnetic and thermal analysis, different
definitions of electric busbar heating were considered and compared.
The busbar system is a three phase one and consists of aluminum,
painted aluminum and copper busbar. The solution to the coupled
field problem is obtained using the finite element method and the
QuickField™ program. Experiments have been carried out using two
different approaches and compared with computed results.
Abstract: Attracting ferromagnetic forces between magnet and reaction rail provide the supporting force in Electromagnetic Suspension. Miniature maglev using permanent magnets and electromagnets is based on the idea to generate the nominal magnetic force by permanent magnets and superimpose the variable magnetic field required for stabilization by currents flowing through control windings in electromagnets. Permanent magnets with a high energy density have lower power losses with regard to supporting force and magnet weight. So the advantage of the maglev using electromagnets and permanent magnets is partially reduced by the power required to feed the remaining onboard supply system so that the overall onboard power is diminished as compared to that of the electromagnet. In this paper we proposed the how to design and control the miniature maglev and confirmed the feasibility of the levitation system using electromagnets and permanent magnets through the manufacturing the miniature maglev