Abstract: Obturator Foramen is a specific structure in Pelvic
bone images and recognition of it is a new concept in medical image
processing. Moreover, segmentation of bone structures such as
Obturator Foramen plays an essential role for clinical research in
orthopedics. In this paper, we present a novel method to analyze the
similarity between the substructures of the imaged region and a hand
drawn template as a preprocessing step for computation of Pelvic
bone rotation on hip radiographs. This method consists of integrated
usage of Marker-controlled Watershed segmentation and Zernike
moment feature descriptor and it is used to detect Obturator Foramen
accurately. Marker-controlled Watershed segmentation is applied to
separate Obturator Foramen from the background effectively. Then,
Zernike moment feature descriptor is used to provide matching
between binary template image and the segmented binary image for
final extraction of Obturator Foramens. Finally, Pelvic bone rotation
rate calculation for each hip radiograph is performed automatically to
select and eliminate hip radiographs for further studies which depend
on Pelvic bone angle measurements. The proposed method is tested
on randomly selected 100 hip radiographs. The experimental results
demonstrated that the proposed method is able to segment Obturator
Foramen with 96% accuracy.
Abstract: The complex shape of the human pelvic bone was
successfully imaged and modeled using finite element FE processing.
The bone was subjected to quasi-static and dynamic loading
conditions simulating the effect of both weight gain and impact.
Loads varying between 500 – 2500 N (~50 – 250 Kg of weight) was
used to simulate 3D quasi-static weight gain. Two different 3D
dynamic analyses, body free fall at two different heights (1 and 2 m)
and forced side impact at two different velocities (20 and 40 Km/hr)
were also studied. The computed resulted stresses were compared for
the four loading cases, where Von Misses stresses increases linearly
with the weight gain increase under quasi-static loading. For the
dynamic models, the Von Misses stress history behaviors were
studied for the affected area and effected load with respect to time.
The normalization Von Misses stresses with respect to the applied
load were used for comparing the free fall and the forced impact load
results. It was found that under the forced impact loading condition
an over lapping behavior was noticed, where as for the free fall the
normalized Von Misses stresses behavior was found to nonlinearly
different. This phenomenon was explained through the energy
dissipation concept. This study will help designers in different
specialization in defining the weakest spots for designing different
supporting systems.