Abstract: This analysis investigates the distortion of flow
measurement and the increase of cavitation along orifice
flowmeter. The analysis using the numerical method (CFD)
validated the distortion of flow measurement through the inlet
velocity profile considering the convergence and grid
dependency. Realizable k-e model was selected and y+ was
about 50 in this numerical analysis. This analysis also estimated
the vulnerability of cavitation effect due to inlet velocity profile.
The investigation concludes that inclined inlet velocity profile
could vary the pressure which was measured at pressure tab
near pipe wall and it led to distort the pressure values ranged
from -3.8% to 5.3% near the orifice plate and to make the
increase of cavitation. The investigation recommends that the
fully developed inlet velocity flow is beneficial to accurate flow
measurement in orifice flowmeter.
Abstract: Design and evaluation of reciprocating compressors
should include a pulsation study. The object is to ensure that
predicted pulsation levels meet guidelines to limit vibration, shaking
forces, noise, associated pressure drops, horsepower losses and
fabrication cost and time to acceptable levels. This paper explains
procedures and recommendations to select and size pulsation
suppression devices to obtain optimum arrangement in terms of
pulsation, vibration, shaking forces, performance, reliability, safety,
operation, maintenance and commercial conditions. Model and
advanced formulations for pulsation study are presented. The effect
of the full fluid dynamic model on the prediction of pulsation waves
and resulting frequency spectrum distributions are discussed.
Advanced and optimum methods of controlling pulsations are
highlighted. Useful recommendations and guidelines for pulsation
control, piping pulsation analysis, pulsation vessel design, shaking
forces, low pressure drop orifices, pulsation study report and devices
to mitigate pulsation and shaking problems are discussed.
Abstract: The present paper represents a methodology for
investigating flow characteristics near orifice plate by using a
commercial computational fluid dynamics code. The flow
characteristics near orifice plate which is located in the auxiliary
feedwater system were modeled via three different levels of grid and
four different types of Reynolds Averaged Navier-Stokes (RANS)
equations with proper near-wall treatment. The results from CFD code
were compared with experimental data in terms of differential pressure
through the orifice plate. In this preliminary study, the Realizable k-ε
and the Reynolds stress models with enhanced wall treatment were
suitable to analyze flow characteristics near orifice plate, and the
results had a good agreement with experimental data.
Abstract: An experiment of vented gas explosions involving two
different cylinder vessel volumes (0.2 and 0.0065 m3) was reported,
with equivalence ratio (Φ) ranged from 0.3 to 1.6. Both vessels were
closed at the rear end and fitted at the other side with a circular
orifice plate that gives a constant vent coefficient (K =Av/V2/3) of
16.4. It was shown that end ignition gives higher overpressures than
central ignition, even though most of the published work on venting
uses central ignition. For propane and ethylene, it is found that rich
mixtures gave the highest overpressures and these mixtures are not
considered in current vent design guidance; which the guideline is
based on mixtures giving the maximum flame temperature. A strong
influence of the vessel volume at constant K was found for methane,
propane, ethylene and hydrogen-air explosions. It can be concluded
that self- acceleration of the flame, which is dependent on the
distance of a flame from the ignition and the ‘suction’ at the vent
opening are significant factors affecting the vent flow during
explosion development in vented gas explosion. This additional
volume influence on vented explosions is not taken into account in
the current vent design guidance.