Abstract: In the present work, an attempt has been made to
understand the feasibility of using UHF technique for identification
of any corona discharges/ arcing in insulating material due to water
droplets. The sensors of broadband type are useful for identification
of such discharges. It is realised that arcing initiated by liquid droplet
radiates UHF signals in the entire bandwidth up to 2 GHz. The
frequency content of the UHF signal generated due to corona/arcing
is not much varied in epoxy nanocomposites with different weight
percentage of clay content. The exfoliated/intercalated properties
were analysed through TEM studies. It is realized that corona
initiated discharges are of intermittent process. The hydrophobicity
of the material characterized through contact angle measurement. It
is realized that low Wt % of nanoclay content in epoxy resin reduces
the surface carbonization due to arcing/corona discharges. The results
of the study with gamma irradiated specimen indicates that contact
angle, discharge inception time and evaporation time of the liquid are
much lower than the virgin epoxy nanocomposite material.
Abstract: Transient shape variation of a rotating liquid dropletis
simulated numerically. The three dimensional Navier-Stokes
equations were solved by using the level set method. The shape
variation from the sphere to the rotating ellipsoid, and to the two-robed
shapeare simulated, and the elongation of the two-robed droplet is
discussed. The two-robed shape after the initial transient is found to be
stable and the elongation is almost the same for the cases with different
initial rotation rate. The relationship between the elongation and the
rotation rate is obtained by averaging the transient shape variation. It is
shown that the elongation of two-robed shape is in good agreement
with the existing experimental data. It is found that the transient
numerical simulation is necessary for analyzing the largely elongated
two-robed shape of rotating droplet.
Abstract: Combustion of sprays is of technological importance, but its flame behavior is not fully understood. Furthermore, the multiplicity of dependent variables such as pressure, temperature, equivalence ratio, and droplet sizes complicates the study of spray combustion. Fundamental study on the influence of the presence of liquid droplets has revealed that laminar flames within aerosol mixtures more readily become unstable than for gaseous ones and this increases the practical burning rate. However, fundamental studies on turbulent flames of aerosol mixtures are limited particularly those under near mono-dispersed droplet conditions. In the present work, centrally ignited expanding flames at near atmospheric pressures are employed to quantify the burning rates in gaseous and aerosol flames. Iso-octane-air aerosols are generated by expansion of the gaseous pre-mixture to produce a homogeneously distributed suspension of fuel droplets. The effects of the presence of droplets and turbulence velocity in relation to the burning rates of the flame are also investigated.
Abstract: Electrophoretic motion of a liquid droplet within an
uncharged cylindrical pore is investigated theoretically in this study. It
is found that the boundary effect in terms of the reduction of droplet
mobility (droplet velocity per unit strength of the applied electric field)
is very significant when the double layer surrounding the droplet is
thick, and diminishes as it gets very thin. Moreover, the viscosity ratio
of the ambient fluid to the internal one, σ, is a crucial factor in
determining its electrophoretic behavior. The boundary effect is less
significant as the viscosity ratio gets high. Up to 70% mobility
reduction is observed when this ratio is low (σ = 0.01), whereas only
40% reduction when it is high (σ = 100). The results of this study can
be utilized in various fields of biotechnology, such as a biosensor or a
lab-on-a-chip device.