Abstract: Condition monitoring of electrical power equipment
has attracted considerable attention for many years. The aim of this
paper is to use Labview with Fuzzy Logic controller to build a
simulation system to diagnose transformer faults and monitor its
condition. The front panel of the system was designed using
LabVIEW to enable computer to act as customer-designed
instrument. The dissolved gas-in-oil analysis (DGA) method was
used as technique for oil type transformer diagnosis; meanwhile
terminal voltages and currents analysis method was used for dry type
transformer. Fuzzy Logic was used as expert system that assesses all
information keyed in at the front panel to diagnose and predict the
condition of the transformer. The outcome of the Fuzzy Logic
interpretation will be displayed at front panel of LabVIEW to show
the user the conditions of the transformer at any time.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM).
Abstract: Seismic qualification testing for equipments to be
mounted on upper storeys of buildings is very demanding in terms of
floor spectra. The latter is characterized by high accelerations
amplitudes within a narrow frequency band. This article presents a
method which permits to cover specified required response spectra
beyond the shaking table capability by amplifying the acceleration
amplitudes at an appropriate frequency range using a physical
intermediate mounted on the platform of the shaker.
Abstract: This paper presents two simplified models to
determine nodal voltages in power distribution networks. These
models allow estimating the impact of the installation of reactive
power compensations equipments like fixed or switched capacitor
banks. The procedure used to develop the models is similar to the
procedure used to develop linear power flow models of transmission
lines, which have been widely used in optimization problems of
operation planning and system expansion. The steady state non-linear
load flow equations are approximated by linear equations relating the
voltage amplitude and currents. The approximations of the linear
equations are based on the high relationship between line resistance
and line reactance (ratio R/X), which is valid for power distribution
networks. The performance and accuracy of the models are evaluated
through comparisons with the exact results obtained from the
solution of the load flow using two test networks: a hypothetical
network with 23 nodes and a real network with 217 nodes.
Abstract: Nowadays, engineering ceramics have significant
applications in different industries such as; automotive, aerospace,
electrical, electronics and even martial industries due to their
attractive physical and mechanical properties like very high hardness
and strength at elevated temperatures, chemical stability, low friction
and high wear resistance. However, these interesting properties plus
low heat conductivity make their machining processes too hard,
costly and time consuming. Many attempts have been made in order
to make the grinding process of engineering ceramics easier and
many scientists have tried to find proper techniques to economize
ceramics' machining processes. This paper proposes a new diamond
plunge grinding technique using ultrasonic vibration for grinding
Alumina ceramic (Al2O3). For this purpose, a set of laboratory
equipments have been designed and simulated using Finite Element
Method (FEM) and constructed in order to be used in various
measurements. The results obtained have been compared with the
conventional plunge grinding process without ultrasonic vibration
and indicated that the surface roughness and fracture strength
improved and the grinding forces decreased.
Abstract: This paper presents the significant factor and give
some suggestion that should know before design. The main objective of this paper is guide the first step for someone who attends to design of grounding system before study in details later. The overview of
grounding system can protect damage from fault such as can save a human life and power system equipment. The unsafe conditions have
three cases. Case 1) maximum touch voltage exceeds the safety
criteria. In this case, the conductor compression ratio of the ground gird should be first adjusted to have optimal spacing of ground grid
conductors. If it still over limit, earth resistivity should be consider afterward. Case 2) maximum step voltage exceeds the safety criteria.
In this case, increasing the number of ground grid conductors around
the boundary can solve this problem. Case 3) both of maximum touch
and step voltage exceed the safety criteria. In this case, follow the solutions explained in case 1 and case 2. Another suggestion, vary depth of ground grid until maximum step and touch voltage do not
exceed the safety criteria.
Abstract: With Power system movement toward restructuring along with factors such as life environment pollution, problems of transmission expansion and with advancement in construction technology of small generation units, it is expected that small units like wind turbines, fuel cells, photovoltaic, ... that most of the time connect to the distribution networks play a very essential role in electric power industry. With increase in developing usage of small generation units, management of distribution networks should be reviewed. The target of this paper is to present a new method for optimal management of active and reactive power in distribution networks with regard to costs pertaining to various types of dispersed generations, capacitors and cost of electric energy achieved from network. In other words, in this method it-s endeavored to select optimal sources of active and reactive power generation and controlling equipments such as dispersed generations, capacitors, under load tapchanger transformers and substations in a way that firstly costs in relation to them are minimized and secondly technical and physical constraints are regarded. Because the optimal management of distribution networks is an optimization problem with continuous and discrete variables, the new evolutionary method based on Ant Colony Algorithm has been applied. The simulation results of the method tested on two cases containing 23 and 34 buses exist and will be shown at later sections.
Abstract: TUSAT is a prospective Turkish
Communication Satellite designed for providing mainly data
communication and broadcasting services through Ku-Band
and C-Band channels. Thermal control is a vital issue in
satellite design process. Therefore, all satellite subsystems and
equipments should be maintained in the desired temperature
range from launch to end of maneuvering life. The main
function of the thermal control is to keep the equipments and
the satellite structures in a given temperature range for various
phases and operating modes of spacecraft during its lifetime.
This paper describes the thermal control design which uses
passive and active thermal control concepts. The active
thermal control is based on heaters regulated by software via
thermistors. Alternatively passive thermal control composes of
heat pipes, multilayer insulation (MLI) blankets, radiators,
paints and surface finishes maintaining temperature level of
the overall carrier components within an acceptable value.
Thermal control design is supported by thermal analysis using
thermal mathematical models (TMM).
Abstract: Soil stabilization has been widely used to improve
soil strength and durability or to prevent erosion and dust generation.
Generally to reduce problems of clayey soils in engineering work and
to stabilize these soils additional materials are used. The most
common materials are lime, fly ash and cement. Using this materials,
although improve soil property , but in some cases due to financial
problems and the need to use special equipment are limited .One of
the best methods for stabilization clayey soils is neutralization the
clay particles. For this purpose we can use ion exchange materials.
Ion exchange solution like CBR plus can be used for soil
stabilization. One of the most important things in using CBR plus is
determination the amount of this solution for various soils with
different properties. In this study a laboratory experiment is conduct
to evaluate the ion exchange capacity of three soils with various
plasticity index (PI) to determine amount or required CBR plus
solution for soil stabilization.
Abstract: In recent years the large scale use of the power electronic equipment has led to an increase of harmonics in the power system. The harmonics results into a poor power quality and have great adverse economical impact on the utilities and customers. Current harmonics are one of the most common power quality problems and are usually resolved by using shunt active filter (SHAF). The main objective of this work is to develop PI and Fuzzy logic controllers (FLC) to analyze the performance of Shunt Active Filter for mitigating current harmonics under balanced and unbalanced sinusoidal source voltage conditions for normal load and increased load. When the supply voltages are ideal (balanced), both PI and FLC are converging to the same compensation characteristics. However, the supply voltages are non-ideal (unbalanced), FLC offers outstanding results. Simulation results validate the superiority of FLC with triangular membership function over the PI controller.
Abstract: In this paper, the modelling and design of artificial neural network architecture for load forecasting purposes is investigated. The primary pre-requisite for power system planning is to arrive at realistic estimates of future demand of power, which is known as Load Forecasting. Short Term Load Forecasting (STLF) helps in determining the economic, reliable and secure operating strategies for power system. The dependence of load on several factors makes the load forecasting a very challenging job. An over estimation of the load may cause premature investment and unnecessary blocking of the capital where as under estimation of load may result in shortage of equipment and circuits. It is always better to plan the system for the load slightly higher than expected one so that no exigency may arise. In this paper, a load-forecasting model is proposed using a multilayer neural network with an appropriately modified back propagation learning algorithm. Once the neural network model is designed and trained, it can forecast the load of the power system 24 hours ahead on daily basis and can also forecast the cumulative load on daily basis. The real load data that is used for the Artificial Neural Network training was taken from LDC, Gujarat Electricity Board, Jambuva, Gujarat, India. The results show that the load forecasting of the ANN model follows the actual load pattern more accurately throughout the forecasted period.
Abstract: To simulate heating systems in buildings, a research oriented computer code has been developed in Sharif University of Technology in Iran where the climate, existing heating equipment in buildings, consumer behavior and their interactions are considered for simulating energy consumption in conventional systems such as heaters, radiators and fan-coils. In order to validate the computer code, the available data of five buildings was used and the computed consumed energy was compared with the estimated energy extracted from monthly bills. The initial heating system was replaced by the alternative system and the effect of this change was observed on the energy consumption. As a result, the effect of changing heating equipment on energy consumption was investigated in different climates. Changing heater to radiator renders energy conservation up to 50% in all climates and changing radiator to fan-coil decreases energy consumption in climates with cold and dry winter.
Abstract: In this paper, we consider a designed and
implemented phase-cutting dimmer. In fact, the dimmer is closed
loop and a microcontroller calculates and then regulates the firing
delay angles of each channel. Depending on the firing angle, the
harmonic distortion in the input current will not comply with
international standards, such as IEC 61000-3-2 (class C equipments).
For solving this problem, eight harmonic compensators have been
added to the dimmer. So, the proposed dimmer has a little harmonic
distortion in the input current whereas conventional phase-cutting
dimmers are not so. Sensitivity and removed THD of the proposed
dimmer will be presented.
Abstract: The system is made with main distributed components:
First Level: Industrial Computers placed in Control Room (monitors thermal and electrical processes based on the data provided by the second level); Second Level: PLCs which collects data from process and transmits information on the first level; also takes commands from this level which are further, passed to execution elements from third
level; Third Level: field elements consisting in 3 categories: data collecting elements; data transfer elements from the third level to the second; execution elements which take commands from the second
level PLCs and executes them after which transmits the confirmation of execution to them. The purpose of the automatic functioning is the optimization of the co-generative electrical energy commissioning in the national
energy system and the commissioning of thermal energy to the consumers.
The integrated system treats the functioning of all the equipments and devices as a whole: Gas Turbine Units (GTU); MT 20kV Medium Voltage Station (MVS); 0,4 kV Low Voltage Station (LVS); Main Hot Water Boilers (MHW); Auxiliary Hot Water Boilers (AHW); Gas Compressor Unit (GCU); Thermal Agent Circulation
Pumping Unit (TPU); Water Treating Station (WTS).
Abstract: This article presents a simple way to perform programmed voice commands for the interface with commercial Digital and Analogue Input/Output PCI cards, used in Robotics and Automation applications. Robots and Automation equipment can "listen" to voice commands and perform several different tasks, approaching to the human behavior, and improving the human- machine interfaces for the Automation Industry. Since most PCI Digital and Analogue Input/Output cards are sold with several DLLs included (for use with different programming languages), it is possible to add speech recognition capability, using a standard speech recognition engine, compatible with the programming languages used. It was created in this work a Visual Basic 6 (the world's most popular language) application, that listens to several voice commands, and is capable to communicate directly with several standard 128 Digital I/O PCI Cards, used to control complete Automation Systems, with up to (number of boards used) x 128 Sensors and/or Actuators.
Abstract: Atmospheric plasma is emerging as a promising
technology for many industrial sectors, because of its ecological and
economic advantages respect to the traditional production processes.
For textile industry, atmospheric plasma is becoming a valid
alternative to the conventional wet processes, but the plasma
machines realized so far do not allow the treatment of fibrous
mechanically weak material.
Novel atmospheric plasma machine for industrial applications,
developed by VenetoNanotech SCpA in collaboration with Italian
producer of corona equipment ME.RO SpA is presented. The main
feature of this pre-industrial scale machine is the possibility of the inline
plasma treatment of delicate fibrous substrates such as fibre
sleeves, for example wool tops, cotton fibres, polymeric tows,
mineral fibers and so on, avoiding burnings and disruption of the
faint materials.
Abstract: The purpose of this paper is to improve electromagnetic characteristics on grounding grid by applying the conductive concrete. The conductive concrete in this study is under an extra high voltage (EHV, 345kV) system located in a high-tech industrial park or science park. Instead of surrounding soil of grounding grid, the application of conductive concrete can reduce equipment damage and body damage caused by switching surges. The focus of the two cases on the EHV distribution system in a high-tech industrial park is presented to analyze four soil material styles. By comparing several soil material styles, the study results have shown that the conductive concrete can effectively reduce the negative damages caused by electromagnetic transient. The adoption of the style of grounding grid located 1.0 (m) underground and conductive concrete located from the ground surface to 1.25 (m) underground can obviously improve the electromagnetic characteristics so as to advance protective efficiency.
Abstract: Public awareness towards green energy are on the rise and this can be prove by many product being manufactured or prerequired to be made as energy saving devices mainly to save consumer from spending more on utility billing. These schemes are popular nowadays and many homemade appliances are turned into energy saving gadget which attracts the attention of consumers. Knowing the public demands and pattern towards purchasing home appliances thus the idea of “energy saving suction hood (ESSH)" is proposed. The ESSH can be used in many places that require smoke ventilation or even to reduce the room temperature as many conventional suction hoods (CSH) do, but this device works automatically by the usage of sensors that detects the smoke/temperature and automatically spins the exhaust fan. As it turns, the mechanical rotation rotates the AC generator which is coupled together with the fan and then charges the battery. The innovation of this product is, it does not rely on the utility supply as it is also hook up with a solar panel which also charges the battery, Secondly, it generates energy as the exhaust fan mechanically rotates. Thirdly, an energy loop back feature is introduced to this system which will supply for the ventilator fan. Another major innovation is towards interfacing this device with an in house production of generator. This generator is produced by proper design on stator as well as rotor to reduce the losses. A comparison is made between the ESSH and the CSH and result shows that the ESSH saves 172.8kWh/year of utility supply which is used by CSH. This amount of energy can save RM 3.14 from monthly utility bill and a total of RM 37.67 per year. In fact this product can generate 175 Watt of power from generator(75W) and solar panel(100W) that can be used either to supply other household appliances and/or to loop back to supply the fans motor. The innovation of this system is essential for future production of other equipment by using the loopback power method and turning most equipment into a standalone system.
Abstract: The case study deals with the semi-quantitative risk
assessment of water resource earmarked for the emergency supply
of population with drinking water. The risk analysis has been based
on previously identified hazards/sensitivities of the elements
of hydrogeological structure and technological equipment of ground
water resource as well as on the assessment of the levels of hazard,
sensitivity and criticality of individual resource elements in the form
of point indexes. The following potential sources of hazard have
been considered: natural disasters caused by atmospheric and
geological changes, technological hazards, and environmental
burdens. The risk analysis has proved that the assessed risks are
acceptable and the water resource may be integrated into a crisis plan
of a given region.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.