Abstract: Seismic qualification testing for equipments to be
mounted on upper storeys of buildings is very demanding in terms of
floor spectra. The latter is characterized by high accelerations
amplitudes within a narrow frequency band. This article presents a
method which permits to cover specified required response spectra
beyond the shaking table capability by amplifying the acceleration
amplitudes at an appropriate frequency range using a physical
intermediate mounted on the platform of the shaker.