Abstract: Doubly-fed induction generators (DFIG) due to their advantages like speed variation and four-quadrant operation, find its application in wind turbines. DFIG besides supplying power to the grid has to support reactive power (kvar) under grid voltage variations, should contribute minimum fault current during faults, have high efficiency, minimum weight, adequate rotor protection during crow-bar-operation from +20% to -20% of rated speed. To achieve the optimum performance, a good electromagnetic design of DFIG is required. In this paper, a simple and heuristic global optimization – Differential Evolution has been used. Variables considered are lamination details such as slot dimensions, stack diameters, air gap length, and generator stator and rotor stack length. Two operating conditions have been considered - voltage and speed variations. Constraints included were reactive power supplied to the grid and limiting fault current and torque. The optimization has been executed separately for three objective functions - maximum efficiency, weight reduction, and grid fault stator currents. Subsequent calculations led to the conclusion that designs determined through differential evolution help in determining an optimum electrical design for each objective function.
Abstract: This paper treats a design of combined control of a
single phase power factor correction (PFC). The strategy of the
proposed control is based on two parts, the first, for the outer loop
(DC output regulated voltage), and the second govern the input
current of the converter in order to achieve a sinusoidal form in phase
with the grid voltage. Two kinds of regulators are used, Fuzzy
controller for the outer loop and predictive controller for the inner
loop. The controllers are verified and discussed through simulation
under MATLAB/Simulink platform. Also an experimental
confirmation is applied. Results present a high dynamic performance
under various parameters changes.
Abstract: This paper presents the modeling and the control of a grid-connected photovoltaic system (PVS). Firstly, the MPPT control of the PVS and its associated DC/DC converter has been analyzed in order to extract the maximum of available power. Secondly, the control system of the grid side converter (GSC) which is a three-phase voltage source inverter (VSI) has been presented. A special attention has been paid to the control algorithms of the GSC converter during grid voltages imbalances. Especially, three different control objectives are to achieve; the mitigation of the grid imbalance adverse effects, at the point of common coupling (PCC), on the injected currents, the elimination of double frequency oscillations in active power flow, and the elimination of double frequency oscillations in reactive power flow. Simulation results of two control strategies have been performed via MATLAB software in order to demonstrate the particularities of each control strategy according to power quality standards.
Abstract: The increasing demand of electric power is giving an
emphasis on the need for the maximum utilization of renewable
energy sources. On the other hand maintaining power quality to
satisfaction of utility is an essential requirement. In this paper the
design aspects of a Unified Power Quality Conditioner integrated
with photovoltaic system in a distributed generation is presented. The
proposed system consist of series inverter, shunt inverter are
connected back to back on the dc side and share a common dc-link
capacitor with Distributed Generation through a boost converter. The
primary task of UPQC is to minimize grid voltage and load current
disturbances along with reactive and harmonic power compensation.
In addition to primary tasks of UPQC, other functionalities such as
compensation of voltage interruption and active power transfer to the
load and grid in both islanding and interconnected mode have been
addressed. The simulation model is design in MATLAB/ Simulation
environment and the results are in good agreement with the published
work.
Abstract: This paper presents a grid synchronization technique based on adaptive notch filter for SPV (Solar Photovoltaic) system along with MPPT (Maximum Power Point Tracking) techniques. An efficient grid synchronization technique offers proficient detection of various components of grid signal like phase and frequency. It also acts as a barrier for harmonics and other disturbances in grid signal. A reference phase signal synchronized with the grid voltage is provided by the grid synchronization technique to standardize the system with grid codes and power quality standards. Hence, grid synchronization unit plays important role for grid connected SPV systems. As the output of the PV array is fluctuating in nature with the meteorological parameters like irradiance, temperature, wind etc. In order to maintain a constant DC voltage at VSC (Voltage Source Converter) input, MPPT control is required to track the maximum power point from PV array. In this work, a variable step size P & O (Perturb and Observe) MPPT technique with DC/DC boost converter has been used at first stage of the system. This algorithm divides the dPpv/dVpv curve of PV panel into three separate zones i.e. zone 0, zone 1 and zone 2. A fine value of tracking step size is used in zone 0 while zone 1 and zone 2 requires a large value of step size in order to obtain a high tracking speed. Further, adaptive notch filter based control technique is proposed for VSC in PV generation system. Adaptive notch filter (ANF) approach is used to synchronize the interfaced PV system with grid to maintain the amplitude, phase and frequency parameters as well as power quality improvement. This technique offers the compensation of harmonics current and reactive power with both linear and nonlinear loads. To maintain constant DC link voltage a PI controller is also implemented and presented in this paper. The complete system has been designed, developed and simulated using SimPower System and Simulink toolbox of MATLAB. The performance analysis of three phase grid connected solar photovoltaic system has been carried out on the basis of various parameters like PV output power, PV voltage, PV current, DC link voltage, PCC (Point of Common Coupling) voltage, grid voltage, grid current, voltage source converter current, power supplied by the voltage source converter etc. The results obtained from the proposed system are found satisfactory.
Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: Most of the PV systems are designed with transformer for safety purpose with galvanic isolation. However, the transformer is big, heavy and expensive. Also, it reduces the overall frequency of the conversion stage. Generally PV inverter with transformer is having efficiency around 92%–94% only. To overcome these problems, transformerless PV system is introduced. It is smaller, lighter, cheaper and higher in efficiency. However, dangerous leakage current will flow between PV array and the grid due to the stray capacitance. There are different types of configurations available for transformerless inverters like H5, H6, HERIC, oH5, and Dual paralleled buck inverter. But each configuration is suffering from its own disadvantages like high conduction losses, shoot-through issues of switches, dead-time requirements at zero crossing instants of grid voltage to avoid grid shoot-through faults and MOSFET reverse recovery issues. The main objective of the proposed transformerless inverter is to address two key issues: One key issue for a transformerless inverter is that it is necessary to achieve high efficiency compared to other existing inverter topologies. Another key issue is that the inverter configuration should not have any shoot-through issues for higher reliability.
Abstract: In this work, an experimental technique is applied
for the measurements of the vibrations and deformation of a test
transformer core. Since the grid voltage contains some higher
harmonics, in addition to a purely sinusoidal magnetisation of the
core the presence of third harmonic is also studied. The vibrations of
the transformer core for points as well as the surface scan of the leg
show more deformation in the corners of the leg than the middle of
the leg. The influence of the higher harmonic of the magnetisation
on the core deformation is also more significant in the corners of the
leg. The core deformation shape under a sinusoidal magnetisation
with a higher harmonic is more wavy and fluctuating than that under
a purely sinusoidal magnetisation.
Abstract: One of the major cause of eye strain and other
problems caused while watching television is the relative illumination between the screen and its surrounding. This can be
overcome by adjusting the brightness of the screen with respect to the surrounding light. A controller based on fuzzy logic is proposed
in this paper. The fuzzy controller takes in the intensity of light
surrounding the screen and the present brightness of the screen as input. The output of the fuzzy controller is the grid voltage corresponding to the required brightness. This voltage is given to CRT and brightness is controller dynamically. For the given test system data, different de-fuzzifier methods have been implemented and the results are compared. In order to validate the effectiveness of
the proposed approach, a fuzzy controller has been designed by obtaining a test data from a real time system. The simulations are
performed in MATLAB and are verified with standard system data. The proposed approach can be implemented for real time
applications.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.