Abstract: Doubly-fed induction generators (DFIG) due to their advantages like speed variation and four-quadrant operation, find its application in wind turbines. DFIG besides supplying power to the grid has to support reactive power (kvar) under grid voltage variations, should contribute minimum fault current during faults, have high efficiency, minimum weight, adequate rotor protection during crow-bar-operation from +20% to -20% of rated speed. To achieve the optimum performance, a good electromagnetic design of DFIG is required. In this paper, a simple and heuristic global optimization – Differential Evolution has been used. Variables considered are lamination details such as slot dimensions, stack diameters, air gap length, and generator stator and rotor stack length. Two operating conditions have been considered - voltage and speed variations. Constraints included were reactive power supplied to the grid and limiting fault current and torque. The optimization has been executed separately for three objective functions - maximum efficiency, weight reduction, and grid fault stator currents. Subsequent calculations led to the conclusion that designs determined through differential evolution help in determining an optimum electrical design for each objective function.
Abstract: In this paper, we develop a dynamic modeling of wind farms in the Jeju power system. The dynamic model of wind farms is developed to study their dynamic effects on the Jeju power system. PSS/E is used to develop the dynamic model of a wind farm composed of 1.5-MW doubly fed induction generators. The output of a wind farm is regulated based on pitch angle control, in which the two controllable parameters are speed and power references. The simulation results confirm that the pitch angle is successfully controlled, regardless of the variation in wind speed and output regulation.
Abstract: Rapid progress in process automation and tightening
quality standards result in a growing demand being placed on fault
detection and diagnostics methods to provide both speed and
reliability of motor quality testing. Doubly fed induction generators
are used mainly for wind energy conversion in MW power plants.
This paper presents a detection of an inter turn stator and an open
phase faults, in a doubly fed induction machine whose stator and
rotor are supplied by two pulse width modulation (PWM) inverters.
The method used in this article to detect these faults, is based on
Park-s Vector Approach, using a neural network.
Abstract: The impact of fixed speed squirrel cage type as well as
variable speed doubly fed induction generators (DFIG) on dynamic
performance of a multimachine power system has been investigated.
Detailed models of the various components have been presented and
the integration of asynchronous and synchronous generators has been
carried out through a rotor angle based transform. Simulation studies
carried out considering the conventional dynamic model of squirrel
cage asynchronous generators show that integration, as such, could
degrade to the AC system performance transiently. This article
proposes a frequency or power controller which can effectively
control the transients and restore normal operation of fixed speed
induction generator quickly. Comparison of simulation results
between classical cage and doubly-fed induction generators indicate
that the doubly fed induction machine is more adaptable to
multimachine AC system. Frequency controller installed in the DFIG
system can also improve its transient profile.