Abstract: In this paper, groundwater seepage into Amirkabir
tunnel has been estimated using analytical and numerical methods for
14 different sections of the tunnel. Site Groundwater Rating (SGR)
method also has been performed for qualitative and quantitative
classification of the tunnel sections. The obtained results of above
mentioned methods were compared together. The study shows
reasonable accordance with results of the all methods unless for two
sections of tunnel. In these two sections there are some significant
discrepancies between numerical and analytical results mainly
originated from model geometry and high overburden. SGR and the
analytical and numerical calculations, confirm high concentration of
seepage inflow in fault zones. Maximum seepage flow into tunnel has
been estimated 0.425 lit/sec/m using analytical method and 0.628
lit/sec/m using numerical method occured in crashed zone. Based on
SGR method, six sections of 14 sections in Amirkabir tunnel axis are
found to be in "No Risk" class that is supported by the analytical and
numerical seepage value of less than 0.04 lit/sec/m.
Abstract: Operations, maintenance and reliability of wind
turbines have received much attention over the years due to the rapid
expansion of wind farms. This paper explores early fault diagnosis
technique for a 5MW wind turbine system subjected to multiple
faults, where genetic optimization algorithm is employed to make the
residual sensitive to the faults, but robust against disturbances. The
proposed technique has a potential to reduce the downtime mostly
caused by the breakdown of components and exploit the productivity
consistency by providing timely fault alarms. Simulation results show
the effectiveness of the robust fault detection methods used under
Matlab/Simulink/Gatool environment.
Abstract: ESPRIT-TLS method appears a good choice for high
resolution fault detection in induction machines. It has a very high
effectiveness in the frequency and amplitude identification.
Contrariwise, it presents a high computation complexity which
affects its implementation in real time fault diagnosis. To avoid this
problem, a Fast-ESPRIT algorithm that combined the IIR band-pass
filtering technique, the decimation technique and the original
ESPRIT-TLS method was employed to enhance extracting accurately
frequencies and their magnitudes from the wind stator current with
less computation cost. The proposed algorithm has been applied to
verify the wind turbine machine need in the implementation of an online,
fast, and proactive condition monitoring. This type of remote
and periodic maintenance provides an acceptable machine lifetime,
minimize its downtimes and maximize its productivity. The
developed technique has evaluated by computer simulations under
many fault scenarios. Study results prove the performance of Fast-
ESPRIT offering rapid and high resolution harmonics recognizing
with minimum computation time and less memory cost.
Abstract: Every machine plays roles of client and server
simultaneously in a peer-to-peer (P2P) network. Though a P2P
network has many advantages over traditional client-server models
regarding efficiency and fault-tolerance, it also faces additional
security threats. Users/IT administrators should be aware of risks
from malicious code propagation, downloaded content legality, and
P2P software’s vulnerabilities. Security and preventative measures
are a must to protect networks from potential sensitive information
leakage and security breaches. Bit Torrent is a popular and scalable
P2P file distribution mechanism which successfully distributes large
files quickly and efficiently without problems for origin server. Bit
Torrent achieved excellent upload utilization according to
measurement studies, but it also raised many questions as regards
utilization in settings, than those measuring, fairness, and Bit
Torrent’s mechanisms choice. This work proposed a block selection
technique using Fuzzy ACO with optimal rules selected using ACO.
Abstract: This paper presents a method of hardening the 8051
micro-controller, able to assure reliable operation in the presence of
bit flips caused by radiation. Aiming at avoiding such faults in the
8051 micro-controller, Hamming code protection was used in its
SRAM memory and registers. A VHDL code has been used for this
hamming code protection.
Abstract: Karst term is the determiner of a variety of areas or
landforms and unique perspectives that have been formed in result of
the of the ingredients dissolution of rocks constituter by natural
waters. Shiraz area with an area of 5322km2 is located in the simple
folded belt in the southern part of Zagros Mountain of Fars, and is
surrounded with Limestone Mountains (Asmari formation). Shiraz
area is located in Calcareous areas. The infrastructure of this city is
lime and absorbing wells that the city can influence the Limestone
dissolution and those accelerate its rate and increase the cavitation
below the surface. Dasht-e Arjan is a graben, which has been created
as the result of activity of two normal faults in its east and west sides.
It is a complete sample of Karst plains (Polje) which has been created
with the help of tectonic forces (fault) and dissolution process of
water in Asmari limestone formation. It is located 60km. off south
west of Shiraz (on Kazeroon-Shiraz road). In 1971, UNESCO has
recognized this plain as a reserve of biosphere. It is considered as one
of the world’s most beautiful geological phenomena, so that most of
the world’s geologists are interested in visiting this place. The
purpose of this paper is to identify and introduce landscapes of Karst
features shiraz city and Dasht-e Arjan including Karst dissolution
features (Lapiez, Karst springs, dolines, caves, underground caves,
ponors, and Karst valleys), anticlines and synclines, and Arjan Lake.
Abstract: Nowadays, Photovoltaic-PV Farms/ Parks and large
PV-Smart Grid Interface Schemes are emerging and commonly
utilized in Renewable Energy distributed generation. However, PVhybrid-
Dc-Ac Schemes using interface power electronic converters
usually has negative impact on power quality and stabilization of
modern electrical network under load excursions and network fault
conditions in smart grid. Consequently, robust FACTS based
interface schemes are required to ensure efficient energy utilization
and stabilization of bus voltages as well as limiting switching/fault
onrush current condition. FACTS devices are also used in smart grid-
Battery Interface and Storage Schemes with PV-Battery Storage
hybrid systems as an elegant alternative to renewable energy
utilization with backup battery storage for electric utility energy and
demand side management to provide needed energy and power
capacity under heavy load conditions. The paper presents a robust
interface PV-Li-Ion Battery Storage Interface Scheme for
Distribution/Utilization Low Voltage Interface using FACTS
stabilization enhancement and dynamic maximum PV power tracking
controllers.
Digital simulation and validation of the proposed scheme is done
using MATLAB/Simulink software environment for Low Voltage-
Distribution/Utilization system feeding a hybrid Linear-Motorized
inrush and nonlinear type loads from a DC-AC Interface VSC-6-
pulse Inverter Fed from the PV Park/Farm with a back-up Li-Ion
Storage Battery.
Abstract: This paper investigates the joint effect of the
interconnected (n,k)-star network topology and Multi-Agent
automated control on restoration and reconfiguration of power
systems. With the increasing trend in development in Multi-Agent
control technologies applied to power system reconfiguration
in presence of faulty components or nodes. Fault tolerance is
becoming an important challenge in the design processes of the
distributed power system topology. Since the reconfiguration of a
power system is performed by agent communication, the (n,k)-star
interconnected network topology is studied and modeled in this
paper to optimize the process of power reconfiguration. In this paper,
we discuss the recently proposed (n,k)-star topology and examine its
properties and advantages as compared to the traditional multi-bus
power topologies. We design and simulate the topology model for
distributed power system test cases. A related lemma based on the
fault tolerance and conditional diagnosability properties is presented
and proved both theoretically and practically. The conclusion is
reached that (n,k)-star topology model has measurable advantages
compared to standard bus power systems while exhibiting fault
tolerance properties in power restoration, as well as showing
efficiency when applied to power system route discovery.
Abstract: Today’s modern interconnected power system is
highly complex in nature. In this, one of the most important
requirements during the operation of the electric power system is the
reliability and security. Power and frequency oscillation damping
mechanism improve the reliability. Because of power system
stabilizer (PSS) low speed response against of major fault such as
three phase short circuit, FACTs devise that can control the network
condition in very fast time, are becoming popular. But FACTs
capability can be seen in a major fault present when nonlinear models
of FACTs devise and power system equipment are applied. To realize
this aim, the model of multi-machine power system with FACTs
controller is developed in MATLAB/SIMULINK using Sim Power
System (SPS) blockiest. Among the FACTs device, Static
synchronous series compensator (SSSC) due to high speed changes
its reactance characteristic inductive to capacitive, is effective power
flow controller. Tuning process of controller parameter can be
performed using different method. But Genetic Algorithm (GA)
ability tends to use it in controller parameter tuning process. In this
paper firstly POD controller is used to power oscillation damping.
But in this station, frequency oscillation dos not has proper damping
situation. So FOD controller that is tuned using GA is using that
cause to damp out frequency oscillation properly and power
oscillation damping has suitable situation.
Abstract: In this paper the CVA computation of interest rate
swap is presented based on its rating. Rating and probability default
given by Moody’s Investors Service are used to calculate our CVA
for a specific swap with different maturities. With this computation
the influence of rating variation can be shown on CVA. Application
is made to the analysis of Greek CDS variation during the period of
Greek crisis between 2008 and 2011. The main point is the
determination of correlation between the fluctuation of Greek CDS
cumulative value and the variation of swap CVA due to change of
rating.
Abstract: Assertion-Based software testing has been shown to
be a promising tool for generating test cases that reveal program
faults. Because the number of assertions may be very large for
industry-size programs, one of the main concerns to the applicability
of assertion-based testing is the amount of search time required to
explore a large number of assertions. This paper presents a new
approach for assertions exploration during the process of Assertion-
Based software testing. Our initial exterminations with the proposed
approach show that the performance of Assertion-Based testing may
be improved, therefore, making this approach more efficient when
applied on programs with large number of assertions.
Abstract: This study is purposed to develop an efficient fault
detection method for Global Navigation Satellite Systems (GNSS)
applications based on adaptive noise covariance estimation. Due to the
dependence on radio frequency signals, GNSS measurements are
dominated by systematic errors in receiver’s operating environment.
In the proposed method, the pseudorange and carrier-phase
measurement noise covariances are obtained at time propagations and
measurement updates in process of Carrier-Smoothed Code (CSC)
filtering, respectively. The test statistics for fault detection are
generated by the estimated measurement noise covariances. To
evaluate the fault detection capability, intentional faults were added to
the filed-collected measurements. The experiment result shows that
the proposed method is efficient in detecting unhealthy measurements
and improves GNSS positioning accuracy against fault occurrences.
Abstract: One of the most important tasks in the risk
management is the correct determination of probability of default
(PD) of particular financial subjects. In this paper a possibility of
determination of financial institution’s PD according to the creditscoring
models is discussed. The paper is divided into the two parts.
The first part is devoted to the estimation of the three different
models (based on the linear discriminant analysis, logit regression
and probit regression) from the sample of almost three hundred US
commercial banks. Afterwards these models are compared and
verified on the control sample with the view to choose the best one.
The second part of the paper is aimed at the application of the chosen
model on the portfolio of three key Czech banks to estimate their
present financial stability. However, it is not less important to be able
to estimate the evolution of PD in the future. For this reason, the
second task in this paper is to estimate the probability distribution of
the future PD for the Czech banks. So, there are sampled randomly
the values of particular indicators and estimated the PDs’ distribution,
while it’s assumed that the indicators are distributed according to the
multidimensional subordinated Lévy model (Variance Gamma model
and Normal Inverse Gaussian model, particularly). Although the
obtained results show that all banks are relatively healthy, there is
still high chance that “a financial crisis” will occur, at least in terms
of probability. This is indicated by estimation of the various quantiles
in the estimated distributions. Finally, it should be noted that the
applicability of the estimated model (with respect to the used data) is
limited to the recessionary phase of the financial market.
Abstract: Supermarkets are the most electricity-intensive type of
commercial buildings. The unsuitable indoor environment of a
supermarket provided by abnormal HVAC operations incurs waste
energy consumption in refrigeration systems. This current study
briefly describes significantly solid backgrounds and proposes easyto-
use analysis terminology for investigating the impact of HVAC
operations on refrigeration power consumption using the field-test
data obtained from building automation system (BAS). With solid
backgrounds and prior knowledge, expected energy interactions
between HVAC and refrigeration systems are proposed through
Pearson’s correlation analysis (R value) by considering correlations
between equipment power consumption and dominantly independent
variables (driving force conditions).The R value can be conveniently
utilized to evaluate how strong relations between equipment
operations and driving force parameters are. The calculated R values
obtained from field data are compared to expected ranges of R values
computed by energy interaction methodology. The comparisons can
separate the operational conditions of equipment into faulty and
normal conditions. This analysis can simply investigate the condition
of equipment operations or building sensors because equipment could
be abnormal conditions due to routine operations or faulty
commissioning processes in field tests. With systematically solid and
easy-to-use backgrounds of interactions provided in the present
article, the procedures can be utilized as a tool to evaluate the proper
commissioning and routine operations of HVAC and refrigeration
systems to detect simple faults (e.g. sensors and driving force
environment of refrigeration systems and equipment set-point) and
optimize power consumption in supermarket buildings. Moreover,
the analysis will be used to further study the FDD research for
supermarkets in future.
Abstract: In new energy development, wind power has boomed.
It is due to the proliferation of wind parks and their operation in
supplying the national electric grid with low cost and clean resources.
Hence, there is an increased need to establish a proactive
maintenance for wind turbine machines based on remote control and
monitoring. That is necessary with a real-time wireless connection in
offshore or inaccessible locations while the wired method has many
flaws. The objective of this strategy is to prolong wind turbine
lifetime and to increase productivity. The hardware of a remote
control and monitoring system for wind turbine parks is designed. It
takes advantage of GPRS or Wi-Max wireless module to collect data
measurements from different wind machine sensors through IP based
multi-hop communication. Computer simulations with Proteus ISIS
and OPNET software tools have been conducted to evaluate the
performance of the studied system. Study findings show that the
designed device is suitable for application in a wind park.
Abstract: This paper presents a 4-DOF nonlinear model of a
cracked de Laval rotor-stator system derived based on Energy
Principles. The model has been used to simulate coupled torsionallateral
response of the faulty system with multiple parametric
excitations; rotor-stator-rub, a breathing transverse crack, eccentric
mass and an axial force. Nonlinearity of a “breathing” crack is
incorporated in the model using a simple hinge mechanism suitable
for a shallow crack. Response of the system while passing via its
critical speed with intermittent rotor-stator rub is analyzed. Effects of
eccentricity with phase and acceleration are investigated. Features of
crack, rub and eccentricity in vibration response are explored for
condition monitoring. The presence of a crack and rub are observable
in the power spectrum despite excitations by an axial force and rotor
unbalance. Obtained results are consistent with existing literature and
could be adopted into rotor condition monitoring strategies.
Abstract: Brain functional networks based on resting-state EEG
data were compared between patients with mild Alzheimer’s disease
(mAD) and matched patients with amnestic subtype of mild cognitive
impairment (aMCI). We integrated the time–frequency cross mutual
information (TFCMI) method to estimate the EEG functional
connectivity between cortical regions and the network analysis based
on graph theory to further investigate the alterations of functional
networks in mAD compared with aMCI group. We aimed at
investigating the changes of network integrity, local clustering,
information processing efficiency, and fault tolerance in mAD brain
networks for different frequency bands based on several topological
properties, including degree, strength, clustering coefficient, shortest
path length, and efficiency. Results showed that the disruptions of
network integrity and reductions of network efficiency in mAD
characterized by lower degree, decreased clustering coefficient, higher
shortest path length, and reduced global and local efficiencies in the
delta, theta, beta2, and gamma bands were evident. The significant
changes in network organization can be used in assisting
discrimination of mAD from aMCI in clinical.
Abstract: Voltage sags are the most common power quality
disturbance in the distribution system. It occurs due to the fault in the
electrical network or by the starting of a large induction motor and
this can be solved by using the custom power devices such as
Dynamic Voltage Restorer (DVR). In this paper DVR is proposed to
compensate voltage sags on critical loads dynamically. The DVR
consists of VSC, injection transformers, passive filters and energy
storage (lead acid battery). By injecting an appropriate voltage, the
DVR restores a voltage waveform and ensures constant load voltage.
The simulation and experimental results of a DVR using MATLAB
software shows clearly the performance of the DVR in mitigating
voltage sags.
Abstract: We used high-precision Global Positioning System
(GPS) to geodetically constrain the motion of stations in the
Darjiling-Sikkim Himalayan (DSH) wedge and examine the
deformation at the Indian-Tibetan plate boundary using IGS
(International GPS Service) fiducial stations. High-precision GPS
based displacement and velocity field was measured in the DSH
between 1997 and 2009. To obtain additional insight north of the
Indo-Tibetan border and in the Darjiling-Sikkim-Tibet (DaSiT)
wedge, published velocities from four stations J037, XIGA, J029 and
YADO were also included in the analysis. India-fixed velocities or
the back-slip was computed relative to the pole of rotation of the
Indian Plate (Latitude 52.97 ± 0.22º, Longitude - 0.30 ± 3.76º, and
Angular Velocity 0.500 ± 0.008º/ Myr) in the DaSiT wedge.
Dislocation modelling was carried out with the back-slip to model the
best possible solution of a finite rectangular dislocation or the
causative fault based on dislocation theory that produced the
observed back-slip using a forward modelling approach. To find the
best possible solution, three different models were attempted. First,
slip along a single thrust fault, then two thrust faults and in finally,
three thrust faults were modelled to simulate the back-slip in the
DaSiT wedge. The three-fault case bests the measured displacements
and is taken as the best possible solution.
Abstract: Most of the PV systems are designed with transformer for safety purpose with galvanic isolation. However, the transformer is big, heavy and expensive. Also, it reduces the overall frequency of the conversion stage. Generally PV inverter with transformer is having efficiency around 92%–94% only. To overcome these problems, transformerless PV system is introduced. It is smaller, lighter, cheaper and higher in efficiency. However, dangerous leakage current will flow between PV array and the grid due to the stray capacitance. There are different types of configurations available for transformerless inverters like H5, H6, HERIC, oH5, and Dual paralleled buck inverter. But each configuration is suffering from its own disadvantages like high conduction losses, shoot-through issues of switches, dead-time requirements at zero crossing instants of grid voltage to avoid grid shoot-through faults and MOSFET reverse recovery issues. The main objective of the proposed transformerless inverter is to address two key issues: One key issue for a transformerless inverter is that it is necessary to achieve high efficiency compared to other existing inverter topologies. Another key issue is that the inverter configuration should not have any shoot-through issues for higher reliability.