Abstract: The application of ESS (Energy Storage Systems) in
the future grids has been the solution of the microgrid. However, high
investment costs necessitate accurate modeling and control strategy of
ESS to justify its economic viability and further underutilization.
Therefore, the reasonable control strategy for ESS which is subjected
to generator and usage helps to curtail the cost of investment and
operation costs. The rated frequency in power system is decreased
when the load is increasing unexpectedly; hence the thermal power is
operated at the capacity of only its 95% for the Governor Free (GF) to
adjust the frequency as reserve (5%) in practice. The ESS can be
utilized with governor at the same time for the frequency response due
to characteristic of its fast response speed and moreover, the cost of
ESS is declined rapidly to the reasonable price. This paper presents the
ESS control strategy to extend usage of the ESS taken account into
governor’s ramp rate and reduce the governor’s intervention as well.
All results in this paper are simulated by MATLAB.
Abstract: The aim of the study is to improve the understanding
of latent and sensible thermal energy storage within a paraffin wax
media by an array of cylindrical tubes arranged both in in-line and
staggered layouts. An analytical and experimental study is carried out
in a horizontal shell-and-tube type system during melting process.
Pertamina paraffin-wax was used as a phase change material (PCM),
while the tubes are embedded in the PCM. From analytical study we
can obtain the useful information in designing a thermal energy
storage such as: the motion of interface, amount of material melted at
any time in the process, and the heat storage characteristic during
melting. The use of staggered tubes is proposed compared to in-line
layout in a heat exchanger as thermal storage. The experimental study
is used to verify the validity of the analytical predictions. From the
comparisons, the analytical and experimental data are in a good
agreement.
Abstract: This paper describes how to dimension the electric
components of a 48V hybrid system considering real customer use.
Furthermore, it provides information about savings in energy and
CO2 emissions by a customer-tailored 48V hybrid. Based on measured customer profiles, the electric units such as the
electric motor and the energy storage are dimensioned. Furthermore,
the CO2 reduction potential in real customer use is determined
compared to conventional vehicles. Finally, investigations are carried
out to specify the topology design and preliminary considerations in
order to hybridize a conventional vehicle with a 48V hybrid system.
The emission model results from an empiric approach also taking into
account the effects of engine dynamics on emissions. We analyzed
transient engine emissions during representative customer driving
profiles and created emission meta models. The investigation showed
a significant difference in emissions when simulating realistic
customer driving profiles using the created verified meta models
compared to static approaches which are commonly used for vehicle
simulation.
Abstract: This paper introduces a method to optimal design of a
hybrid Wind/Photovoltaic/Fuel cell generation system for a typical
domestic load that is not located near the electricity grid. In this
configuration the combination of a battery, an electrolyser, and a
hydrogen storage tank are used as the energy storage system. The aim
of this design is minimization of overall cost of generation scheme
over 20 years of operation. The Matlab/Simulink is applied for
choosing the appropriate structure and the optimization of system
sizing. A teaching learning based optimization is used to optimize the
cost function. An overall power management strategy is designed for
the proposed system to manage power flows among the different
energy sources and the storage unit in the system. The results have
been analyzed in terms of technical and economic. The simulation
results indicate that the proposed hybrid system would be a feasible
solution for stand-alone applications at remote locations.
Abstract: The use of Flexible AC Transmission System
(FACTS) devices in a power system can potentially overcome
limitations of the present mechanically controlled transmission
system. Also, the advance of technology makes possible to include
new energy storage devices in the electrical power system. The
integration of Superconducting Magnetic Energy Storage (SMES)
into Static Synchronous Compensator (STATCOM) can lead to
increase their flexibility in improvement of power system dynamic
behaviour by exchanging both active and reactive powers with power
grids. This paper describes structure and behaviour of SMES,
specifications and performance principles of the STATCOM/SMES
compensator. Moreover, the benefits and effectiveness of integrated
SMES with STATCOM in power systems is presented. Also, the
performance of the STATCOM/SMES compensator is evaluated
using an IEEE 3-bus system through the dynamic simulation by
PSCAD/EMTDC software.
Abstract: The use of hydroelectric pump-storage system at large
scale, MW-size systems, is already widespread around the world.
Designed for large scale applications, pump-storage station can be
scaled-down for small, remote residential applications. Given the cost
and complexity associated with installing a substation further than
100 miles from the main transmission lines, a remote, independent
and self-sufficient system is by far the most feasible solution. This
article is aiming at the design of wind and solar power generating
system, by means of pumped-storage to replace the wind and /or solar
power systems with a battery bank energy storage. Wind and solar
pumped-storage power generating system can reduce the cost of
power generation system, according to the user's electricity load and
resource condition and also can ensure system reliability of power
supply. Wind and solar pumped-storage power generation system is
well suited for remote residential applications with intermittent wind
and/or solar energy. This type of power systems, installed in these
locations, could be a very good alternative, with economic benefits
and positive social effects. The advantage of pumped storage power
system, where wind power regulation is calculated, shows that a
significant smoothing of the produced power is obtained, resulting in
a power-on-demand system’s capability, concomitant to extra
economic benefits.
Abstract: Nowadays, the use of renewable energy sources has been increasingly great because of the cost increase and public demand for clean energy sources. One of the fastest growing sources is wind energy. In this paper, Wind Diesel Hybrid System (WDHS) comprising a Diesel Generator (DG), a Wind Turbine Generator (WTG), the Consumer Load, a Battery-based Energy Storage System (BESS), and a Dump Load (DL) is used. Voltage is controlled by Diesel Generator; the frequency is controlled by BESS and DL. The BESS elimination is an efficient way to reduce maintenance cost and increase the dynamic response. Simulation results with graphs for the frequency of Power System, active power, and the battery power are presented for load changes. The controlling parameters are optimized by using Imperialist Competitive Algorithm (ICA). The simulation results for the BESS/no BESS cases are compared. Results show that in no BESS case, the frequency control is more optimal than the BESS case by using ICA.
Abstract: Hybrid electric vehicles can reduce pollution and
improve fuel economy. Power-split hybrid electric vehicles (HEVs)
provide two power paths between the internal combustion engine
(ICE) and energy storage system (ESS) through the gears of an
electrically variable transmission (EVT). EVT allows ICE to operate
independently from vehicle speed all the time. Therefore, the ICE can
operate in the efficient region of its characteristic brake specific fuel
consumption (BSFC) map. The two-mode powertrain can operate in
input-split or compound-split EVT modes and in four different fixed
gear configurations. Power-split architecture is advantageous because
it combines conventional series and parallel power paths. This
research focuses on input-split and compound-split modes in the
two-mode power-split powertrain. Fuzzy Logic Control (FLC) for an
internal combustion engine (ICE) and PI control for electric machines
(EMs) are derived for the urban driving cycle simulation. These
control algorithms reduce vehicle fuel consumption and improve ICE
efficiency while maintaining the state of charge (SOC) of the energy
storage system in an efficient range.
Abstract: The efficiency of the actuation system of exoskeletons
and active orthoses for lower limbs is a significant aspect of the
design of such devices because it affects their efficacy. The F-IVT is
an innovative actuation system to power artificial knee joint with
energy recovery capabilities. Its key and non-conventional elements
are a flywheel that acts as a mechanical energy storage system, and
an Infinitely Variable Transmission (IVT). The design of the F-IVT
can be optimized for a certain walking condition, resulting in a heavy
reduction of both the electric energy consumption and of the electric
peak power. In this work, by means of simulations of level ground
walking at different speeds, it is demonstrated that the F-IVT is still
an advantageous actuator which permits to save energy consumption
and to downsize the electric motor even when it does not work in
nominal conditions.
Abstract: Flexible AC Transmission Systems (FACTS) is
granting a new group of advanced power electronic devices emerging
for enhancement of the power system performance. Unified Power
Flow Controller (UPFC) is a recent version of FACTS devices for
power system applications. The back-up energy supply system
incorporated with UPFC is providing a complete control of real and
reactive power at the same time and hence is competent to improve
the performance of an electrical power system. In this article, backup
energy supply unit such as superconducting magnetic energy storage
(SMES) is integrated with UPFC. In addition, comparative
exploration of UPFC–battery, UPFC–UC and UPFC–SMES
performance is evaluated through the vibrant simulation by using
MATLAB/Simulink software.
Abstract: Surplus electricity can be converted into potential energy via pumped hydroelectric storage for future usage. Similarly, thermo-electric energy storage (TEES) uses heat pumps equipped with thermal storage to convert electrical energy into thermal energy; the stored energy is then converted back into electrical energy when necessary using a heat engine. The greatest advantage of this method is that, unlike pumped hydroelectric storage and compressed air energy storage, TEES is not restricted by geographical constraints. In this study, performance variation of the TEES according to the changes in cold-side storage temperature was investigated by simulation method.
Abstract: The advent of Flexible AC Transmission Systems (FACTS) is giving rise to a new family of power electronic equipment emerging for controlling and optimizing the performance of power system, e.g. STATCOM. Static synchronous Compensator (STATCOM) is a commonly used FACTS device and has been successfully applied in power systems. In this sense, superconducting magnetic energy storage (SMES) in integration with a static synchronous compensator (STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper the structure and characteristics of the STATCOM/SMES is proposed. In addition, using a proper control scheme, STATCOM/ SMES is tested on an IEEE 3-bus system and more effective performance of the presented STATCOM/SMES compensator is evaluated with alone STATCOM through the dynamic simulation by using PSCAD/EMTDC software.
Abstract: Nowadays the growth of distributed generation within the bulk power system is feasible by using the optimal control of the transmission lines power flow. Static Synchronous Compensators (STATCOM) is effective for improving voltage stability but it can only exchange reactive power with the power grid. The integration of Superconducting Magnetic Energy Storage (SMES) with a STATCOM can extend the traditional STATCOM capabilities to four-quadrant bulk power system power flow control and providing exchange both the active and reactive power related to the STATCOM with the ac network. This paper shows how the SMES system can be connected to the ac system via the DC bus of a STATCOM and also analyzes how the integration of STATCOM and SMES allows the bus voltage regulation and power oscillation damping (POD) to be achieved simultaneously. The dynamic performance of the integrated STATCOM-SMES is evaluated through simulation by using PSCAD/EMTDC software and the compensation effectiveness of this integrated compensator is shown.
Abstract: Packaging for vanadium redox flow battery is one of the key elements for successful implementation of flow battery in the electrical energy storage system. Usually the bulky battery size and low energy densities make this technology not available for mobility application. ThereforeRFB with improved packaging size and energy capacity are highly desirable. This paper focuses on the study of packaging improvement for unit cell V-RFB to the application on Series Hybrid Electric Vehicle. Two different designs of 25cm2 and 100cm2 unit cell V-RFB at same current density are used for the sample in this investigation. Further suggestions on packaging improvement are highlighted.
Abstract: Owing to the lack of synchronization between the solar energy availability and the heat demands in a specific application, the energy storing sub-system is necessary to maintain the continuity of thermal process. The present work is dealing with an active solar heating storing system in which an air solar collector is connected to storing unit where this energy is distributed and provided to the heated space in a controlled manner. The solar collector is a box type absorber where the air flows between a number of vanes attached between the collector absorber and the bottom plate. This design can improve the efficiency due to increasing the heat transfer area exposed to the flowing air, as well as the heat conduction through the metal vanes from the top absorbing surface. The storing unit is a packed bed type where the air is coming from the air collector and circulated through the bed in order to add/remove the energy through the charging / discharging processes, respectively. The major advantage of the packed bed storage is its high degree of thermal stratification. Numerical solution of the packed bed energy storage is considered through dividing the bed into a number of equal segments for the bed particles and solved the energy equation for each segment depending on the neighbor ones. The studied design and performance parameters in the developed simulation model including, particle size, void fraction, etc. The final results showed that the collector efficiency was fluctuated between 55%-61% in winter season (January) under the climatic conditions of Misurata in Libya. Maximum temperature of 52ºC is attained at the top of the bed while the lower one is 25ºC at the end of the charging process of hot air into the bed. This distribution can satisfy the required load for the most house heating in Libya.
Abstract: Most ZigBee sensor networks to date make use of nodes with limited processing, communication, and energy capabilities. Energy consumption is of great importance in wireless sensor applications as their nodes are commonly battery-driven. Once ZigBee nodes are deployed outdoors, limited power may make a sensor network useless before its purpose is complete. At present, there are two strategies for long node and network lifetime. The first strategy is saving energy as much as possible. The energy consumption will be minimized through switching the node from active mode to sleep mode and routing protocol with ultra-low energy consumption. The second strategy is to evaluate the energy consumption of sensor applications as accurately as possible. Erroneous energy model may render a ZigBee sensor network useless before changing batteries.
In this paper, we present a ZigBee wireless sensor node with four key modules: a processing and radio unit, an energy harvesting unit, an energy storage unit, and a sensor unit. The processing unit uses CC2530 for controlling the sensor, carrying out routing protocol, and performing wireless communication with other nodes. The harvesting unit uses a 2W solar panel to provide lasting energy for the node. The storage unit consists of a rechargeable 1200 mAh Li-ion battery and a battery charger using a constant-current/constant-voltage algorithm. Our solution to extend node lifetime is implemented. Finally, a long-term sensor network test is used to exhibit the functionality of the solar powered system.
Abstract: Nowadays the use of Hybrid Electric Vehicles (HEV) is increasing dramatically. The HEV is mainly dependent on electricity and there is always a need for storage of charge. Fuel Cell (FC), Batteries and Ultra Capacitor are being used for the proposed HEV as an electric power source or as an energy storage unit. The aim of developing an energy management technique is to utilize the sources according to the requirement of the vehicle with help of controller. This increases the efficiency of hybrid electric vehicle to reduce the fuel consumption and unwanted emission. The Maximum Power Point Tracking (MPPT) in FC is done using (Perturb & Observe) algorithm. In this paper, the control of automobiles at variable speed is achieved effectively.
Abstract: In this paper a hybrid distributed generation (DG) system connected to isolated load is studied. The DG system consisting of photo voltaic (PV) system, fuel cells, aqua electrolyzer, diesel engine generator and a battery energy storage system. The ambient temperature value of PV is taken as constant to make the output power of PV is directly proportional to the radiation and output power of other DG sources and frequency of the system is controlled by simple integral (I), proportional plus integral (PI), and proportional plus integral and derivative(PID) controllers. A maiden attempt is made to apply a more recent and powerful optimization technique named as bacterial foraging technique for optimization of controllers gains of the proposed hybrid DG system. The system responses with bacterial foraging based controllers are compared with that of classical method. Investigations reveal that bacterial foraging based controllers gives better responses than the classical method and also PID controller is best. Sensitivity analysis is carried out which demonstrates the robustness of the optimized gain values for system loading condition.
Abstract: This paper investigates the energy storage
technologies that can potentially enhance the use of solar energy.
Water electrolysis systems are seen as the principal means of
producing a large amount of hydrogen in the future. Starting from the
analysis of the models of the system components, a complete
simulation model was realized in the Matlab-Simulink environment.
Results of the numerical simulations are provided. The operation of
electrolysis and photovoltaic array combination is verified at various
insulation levels. It is pointed out that solar cell arrays and
electrolysers are producing the expected results with solar energy
inputs that are continuously varying.
Abstract: In recent years Li-Ion batteries getting more attention among the Electrical Vehicles (EV) and Hybrid Electrical Vehicles (HEV) energy storage. Li-Ion has shown extended power density and light weight compared to other batteries readily available in the market. One of the major drawbacks in Li-Ion batteries is their sensitivity to the temperature. If the working temperature is beyond the limit, that could affect seriously on the durability and performance of Li-Ion battery. Thus Battery Thermal Management (BTM) is the most essential in adapting Li-Ion battery to the EVs and HEVs.