Abstract: In this paper, we report the experimental results on using complementary Golay coded signals at 7.5 MHz to detect breast microcalcifications of 50 µm size. Simulations using complementary Golay coded signals show perfect consistence with the experimental results, confirming the improved signal to noise ratio for complementary Golay coded signals. For improving the success on detecting the microcalcifications, orthogonal complementary Golay sequences having cross-correlation for minimum interference are used as coded signals and compared to tone burst pulse of equal energy in terms of resolution under weak signal conditions. The measurements are conducted using an experimental ultrasound research scanner, Digital Phased Array System (DiPhAS) having 256 channels, a phased array transducer with 7.5 MHz center frequency and the results obtained through experiments are validated by Field-II simulation software. In addition, to investigate the superiority of coded signals in terms of resolution, multipurpose tissue equivalent phantom containing series of monofilament nylon targets, 240 µm in diameter, and cyst-like objects with attenuation of 0.5 dB/[MHz x cm] is used in the experiments. We obtained ultrasound images of monofilament nylon targets for the evaluation of resolution. Simulation and experimental results show that it is possible to differentiate closely positioned small targets with increased success by using coded excitation in very weak signal conditions.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: In the paper the study of synthetic transmit aperture
method applying the Golay coded transmission for medical
ultrasound imaging is presented. Longer coded excitation allows to
increase the total energy of the transmitted signal without increasing
the peak pressure. Moreover signal-to-noise ratio and penetration
depth are improved while maintaining high ultrasound image
resolution. In the work the 128-element linear transducer array with
0.3 mm inter-element spacing excited by one cycle and the 8 and 16-
bit Golay coded sequences at nominal frequency 4 MHz was used. To
generate a spherical wave covering the full image region a single
element transmission aperture was used and all the elements received
the echo signals. The comparison of 2D ultrasound images of the
tissue mimicking phantom and in vitro measurements of the beef liver
is presented to illustrate the benefits of the coded transmission. The
results were obtained using the synthetic aperture algorithm with
transmit and receive signals correction based on a single element
directivity function.