Abstract: We propose new multiple-channel piezoelectric (PZT)
actuated tunable optical filter based on racetrack multi-ring
resonators for wavelength de-multiplexing network applications. We
design tunable eight-channel wavelength de-multiplexer consisting of
eight cascaded PZT actuated tunable multi-ring resonator filter with a
channel spacing of 1.6nm. The filter for each channel is basically
structured on a suspended beam, sandwiched with piezoelectric
material and built in integrated ring resonators which are placed on
the middle of the beam to gain uniform stress and linearly varying
longitudinal strain. A reference single mode serially coupled multi
stage racetrack ring resonator with the same radii and coupling length
is designed with a line width of 0.8974nm with a flat top pass band at
1dB of 0.5205nm and free spectral range of about 14.9nm. In each
channel, a small change in the perimeter of the rings is introduced to
establish the shift in resonance wavelength as per the defined channel
spacing. As a result, when a DC voltage is applied, the beams will
elongate, which involves mechanical deformation of the ring
resonators that induces a stress and a strain, which brings a change in
refractive index and perimeter of the rings leading to change in the
output spectrum shift providing the tunability of central wavelength
in each channel. Simultaneous wave length shift as high as
45.54pm/
Abstract: The article deals with the tool in Matlab GUI form
that is designed to analyse a mechatronic system sensitivity and
tolerance. In the analysed mechatronic system, a torque is transferred
from the drive to the load through a coupling containing flexible
elements. Different methods of control system design are used. The
classic form of the feedback control is proposed using Naslin method,
modulus optimum criterion and inverse dynamics method. The
cascade form of the control is proposed based on combination of
modulus optimum criterion and symmetric optimum criterion. The
sensitivity is analysed on the basis of absolute and relative sensitivity
of system function to the change of chosen parameter value of the
mechatronic system, as well as the control subsystem. The tolerance
is analysed in the form of determining the range of allowed relative
changes of selected system parameters in the field of system stability.
The tool allows to analyse an influence of torsion stiffness, torsion
damping, inertia moments of the motor and the load and controller(s)
parameters. The sensitivity and tolerance are monitored in terms of
the impact of parameter change on the response in the form of system
step response and system frequency-response logarithmic
characteristics. The Symbolic Math Toolbox for expression of the
final shape of analysed system functions was used. The sensitivity
and tolerance are graphically represented as 2D graph of sensitivity
or tolerance of the system function and 3D/2D static/interactive graph
of step/frequency response.
Abstract: Multi-Level Inverter technology has been developed in the area of high-power medium-voltage energy scheme, because of their advantages such as devices of lower rating can be used thereby enabling the schemes to be used for high voltage applications. Reduced Total Harmonic Distortion (THD).Since the dv/dt is low; the Electromagnetic Interference from the scheme is low. To avoid the switching losses Lower switching frequencies can be used. In this paper present a survey of various topologies, control strategy and modulation techniques used by these inverters. Here the regenerative and superior topologies are also discussed.
Abstract: At present, the cascade PID control is widely used to
control the superheating temperature (main steam temperature). As
Main Steam Temperature has the characteristics of large inertia, large
time-delay and time varying, etc., conventional PID control strategy
cannot achieve good control performance. In order to overcome the
bad performance and deficiencies of main steam temperature control
system, Model Free Adaptive Control (MFAC) - P cascade control
system is proposed in this paper. By substituting MFAC in PID of the
main control loop of the main steam temperature control, it can
overcome time delays, non-linearity, disturbance and time variation.
Abstract: In this report we have discussed the theoretical aspects
of the flow transformation, occurring through a series of bifurcations.
The parameters and their continuous diversion, the intermittent bursts
in the transition zone, variation of velocity and pressure with time,
effect of roughness in turbulent zone, and changes in friction factor
and head loss coefficient as a function of Reynolds number for a
transverse flow across a cylinder have been discussed. An analysis of
the variation in the wake length with Reynolds number was done in
FORTRAN.
Abstract: In this paper family of multilevel inverter topology
with reduced number of power switches is presented. The proposed
inverter can generate both even and odd level. The proposed topology
is suitable for symmetric structure. The proposed symmetric inverter
results in reduction of power switches, power diode and gate driver
circuits and also it may further minimize the installation area and
cost. To prove the superiority of proposed topology is compared with
conventional topologies. The performance of this symmetric
multilevel inverter has been tested by computer based simulation and
prototype based experimental setup for nine-level inverter is
developed and results are verified.
Abstract: Anultra-low power capacitor less low-dropout voltage
regulator with improved transient response using gain enhanced feed
forward path compensation is presented in this paper. It is based on a
cascade of a voltage amplifier and a transconductor stage in the feed
forward path with regular error amplifier to form a composite gainenhanced
feed forward stage. It broadens the gain bandwidth and thus
improves the transient response without substantial increase in power
consumption. The proposed LDO, designed for a maximum output
current of 100 mA in UMC 180 nm, requires a quiescent current of
69 )A. An undershot of 153.79mV for a load current changes from
0mA to 100mA and an overshoot of 196.24mV for current change of
100mA to 0mA. The settling time is approximately 1.1 )s for the
output voltage undershooting case. The load regulation is of 2.77
)V/mA at load current of 100mA. Reference voltage is generated by
using an accurate band gap reference circuit of 0.8V.The costly
features of SOC such as total chip area and power consumption is
drastically reduced by the use of only a total compensation
capacitance of 6pF while consuming power consumption of 0.096
mW.
Abstract: This paper presents a neural network based model predictive control (MPC) strategy to control a strongly exothermic reaction with complicated nonlinear kinetics given by Chylla-Haase polymerization reactor that requires a very precise temperature control to maintain product uniformity. In the benchmark scenario, the operation of the reactor must be guaranteed under various disturbing influences, e.g., changing ambient temperatures or impurity of the monomer. Such a process usually controlled by conventional cascade control, it provides a robust operation, but often lacks accuracy concerning the required strict temperature tolerances. The predictive control strategy based on the RBF neural model is applied to solve this problem to achieve set-point tracking of the reactor temperature against disturbances. The result shows that the RBF based model predictive control gives reliable result in the presence of some disturbances and keeps the reactor temperature within a tight tolerance range around the desired reaction temperature.
Abstract: The Montreal protocol and Kyoto protocol underlined the need of substitution of CFC’s and HCFC’s due to their adverse impact on atmospheric ozone layer which protects earth from U.V rays. The CFCs have been entirely ruled out since 1995 and a long-term basis HCFCs must be replaced by 2020. All this events motivated HFC refrigerants which are harmless to ozone layer. In this paper thermodynamic analysis of cascade refrigeration system has been done using three different refrigerant pairs R13-R12, R290-R23, and R404A-R23. Effect of various operating parameters i.e. evaporator temperature, condenser temperature, temperature difference in cascade condenser and low temperature cycle condenser temperature on performance parameters viz. COP, exergetic efficiency and refrigerant mass flow ratio have been studied. Thermodynamic analysis shows that out of three refrigerant pairs R12-R13, R290-R23 and R404A-R23 the COP of R290-R23 refrigerant pair is highest.
Abstract: This research aims to study the Zinc (Zn) concentration in fine particulate matter on Rajchawithee roadside in rush hour. 30 Samples were collected in Jun to August 2013 by 8 stage non-avaible cascade impactor. Each samples (filter paper) were digest with nitric acid and analyed by atomic absorption spectrophotometer for Zinc determination. The highest value for the mean fraction (18.00 ± 9.28%) is the size 9.0 – 110.0 micron follow by the range 3.3 – 4.7 micron (14.77 ± 14.66 %) and 1.1 – 2.1 micron (14.01 ± 11.77 %). The concentration of Zn in the particulate matter of range 0.43 – 0.7mm, 0.7 – 1.1 mm, 1.1 – 2.1 mm, 2.1 – 3.3 mm, 3.3 – 4.7 mm, 4.7 – 5.8 mm, 5.8 – 9.0 mm, 9.0 – 10.0 mm, were 41.56 – 217.62 mg/m3 (175.86 ±32.25 mg/m3), 152.60 – 217.24 mg/m3 (187.71 ± 17.42 mg/m3), 142.90 – 214.67 mg/m3(180.95 ± 18.71 mg/m3), 155.48 – 218.19 mg/m3(183.22 ± 19.94 mg/m3), 151.72 – 217.39 mg/m3(181.85 ± 17.57 mg/m3), 133.86 – 220.17 mg/m3 (178.78 ± 23.45 mg/m3), 160.00 – 220.35 mg/m3 (182.58 ± 18.08 mg/m3), 153.30 – 226.70 mg/m3 (181.52 ± 20.05 mg/m3), respectively. The Zn concentration in each size of particulate matter was not statistically significant different (p > .005)
Abstract: Unwanted side effects because of spectral aliasing and spectral imaging during signal processing would be the major concern over the sampling rate alteration. Multirate-multistage implementation of digital filter could come about a large computational saving than single rate filter suitable for sample rate conversion. This implementation can further improve through high-level architectural transformation in circuit level. Reallocating registers and relocating flip-flops across logic gates through retiming certainly a prominent sequential transformation technology, that optimize hardware circuits to achieve faster clocking speed without affecting the functionality. In this paper, we proposed an efficient compensated cascade Integrator comb (CIC) decimation filter structure that analyze the consequence of filter order variation which has a retimed FIR filter being compensator while using the cutset retiming technique and achieved an improvement in the passband droop by 14% to 39%, in computation time by 38.04%, 25.78%, 12.21%, 6.69% and 4.44% and reduction in path delay by 62.27%, 72%, 86.63%, 91.56% and 94.42% of 3, 6, 8, 12 and 24 order filter respectively than the non-retimed CIC compensation filter.
Abstract: Multilevel inverters such as flying capacitor, diodeclamped,
and cascaded H-bridge inverters are very popular
particularly in medium and high power applications. This paper
focuses on a cascaded H-bridge module using a single direct current
(DC) source in order to generate an 11-level output voltage. The
noble approach reduces the number of switches and gate drivers, in
comparison with a conventional method. The anticipated topology
produces more accurate result with an isolation transformer at high
switching frequency. Different modulation techniques can be used for
the multilevel inverter, but this work features modulation techniques
known as selective harmonic elimination (SHE).This modulation
approach reduces the number of carriers with reduction in Switching
Losses, Total Harmonic Distortion (THD), and thereby increasing
Power Quality (PQ). Based on the simulation result obtained, it
appears SHE has the ability to eliminate selected harmonics by
chopping off the fundamental output component. The performance
evaluation of the proposed cascaded multilevel inverter is performed
using PSIM simulation package and THD of 0.94% is obtained.
Abstract: Multilevel inverter is a promising inverter topology for high voltage and high power applications. This inverter synthesizes several different levels of DC voltages to produce a stepped AC output that approaches the pure sine waveform. The three different topologies, diode-clamped inverter, capacitor-clamped inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each PV array can act as a separate dc source for each h-bridge module. This research especially focus on photovoltaic power source as input to the system and shows the potential of a Single Phase Cascaded H-bridge Eleven level inverter governed by the fuzzy logic controller to improve the power quality by reducing the total harmonic distortion at the output voltage. Hence the efficiency of the system will be improved. Simulation using MATLAB/SIMULINK has been done to verify the performance of cascaded h-bridge eleven level inverter using sinusoidal pulse width modulation technique. The simulated output shows very favorable result.
Abstract: Cascade refrigeration systems employ series of single stage vapor compression units which are thermally coupled with evaporator/condenser cascades. Different refrigerants are used in each of the circuit depending on the optimum characteristics shown by the refrigerant for a particular application. In the present research study, a steady state thermodynamic model is developed which simulates the working of an actual cascade system. The model provides COP and all other system parameters e.g. total compressor work, temperature, pressure, enthalpy and entropy at different state points. The working fluid in low temperature circuit (LTC) is CO2 (R744) while Ammonia (R717), Propane (R290), Propylene (R1270), R404A and R12 are the refrigerants in high temperature circuit (HTC). The performance curves of Ammonia, Propane, Propylene, and R404A are compared with R12 to find its nearest substitute. Results show that Ammonia is the best substitute of R12.
Abstract: In this work, the main problem considered is the
detection and the isolation of the actuator fault. A new formulation of
the linear system is generated to obtain the conditions of the actuator
fault diagnosis. The proposed method is based on the representation
of the actuator as a subsystem connected with the process system in
cascade manner. The designed formulation is generated to obtain the
conditions of the actuator fault detection and isolation. Detectability
conditions are expressed in terms of the invertibility notions. An
example and a comparative analysis with the classic formulation
illustrate the performances of such approach for simple actuator fault
diagnosis by using the linear model of nuclear reactor.
Abstract: This paper presents an idea for analog current comparison which compares input signal and reference currents with high speed and accuracy. Proposed circuit utilizes amplification properties of common gate configuration, where voltage variations of input current are amplified and a compared output voltage is developed. Cascaded inverter stages are used to generate final CMOS compatible output voltage. Power consumption of circuit can be controlled by the applied gate bias voltage. The comparator is designed and studied at 180nm CMOS process technology for a supply voltage of 3V.
Abstract: Any digital processing performed on a signal with larger nyquist interval requires more computation than signal processing performed on smaller nyquist interval. The sampling rate alteration generates the unwanted effects in the system such as spectral aliasing and spectral imaging during signal processing. Multirate-multistage implementation of digital filter can result a significant computational saving than single rate filter designed for sample rate conversion. In this paper, we presented an efficient cascaded integrator comb (CIC) decimation filter that perform fast down sampling using signed digit adder algorithm with compensated frequency droop that arises due to aliasing effect during the decimation process. This proposed compensated CIC decimation filter structure with a hybrid signed digit (HSD) fast adder provide an improved performance in terms of down sampling speed by 65.15% than ripple carry adder (RCA) and reduced area and power by 57.5% and 0.01 % than signed digit (SD) adder algorithms respectively.
Abstract: An expressed sequence tag (EST) analysis provideus portions of expressed genes. We have constructed cDNA library and determined randomly sequences from cDNA library clones of T. molitor injected with acholeplasma lysate. We identified the homologous to a galectin gene. As the result of cloning and characterization of novel, we found that the protein has an open reading frame (ORF) of 495 bp, with 164 amino acid residues and molecular weight of 18.5 kDa. To characterize the role of novel Tm-galectin in immune system, we quantified the mRNA level of galectin at different times after treatment with immune elicitors. The galectin mRNA was up-regulated about 7-folds within 18 hrs. This suggests that Tm-galectin is a novel member of animal lectins, and has a role in the process of pathogen recognition. Our study would be helpful for the study on immune defense system and signaling cascade.
Abstract: The aim of this paper is to identify an optimum
control strategy of three-phase shunt active filters to minimize the total harmonic distortion factor of the supply current. A classical PIPI cascade control solution of the output current of the active filterand the voltage across the DC capacitor based on Modulus–Optimum
criterion is taken into consideration. The control system operation
has been simulated using Matlab-Simulink environment and the results agree with the theoretical expectation. It is shown that there is
an optimum value of the DC-bus voltage which minimizes the supply current harmonic distortion factor. It corresponds to the equality of the apparent power at the output of the active filter and the apparent power across the capacitor. Finally, predicted results are verified experimentally on a MaxSine active power filter.
Abstract: Rotor Flux based Model Reference Adaptive System
(RF-MRAS) is the most popularly used conventional speed
estimation scheme for sensor-less IM drives. In this scheme, the
voltage model equations are used for the reference model. This
encounters major drawbacks at low frequencies/speed which leads to
the poor performance of RF-MRAS. Replacing the reference model
using Neural Network (NN) based flux estimator provides an
alternate solution and addresses such drawbacks. This paper
identifies an NN based flux estimator using Single Neuron Cascaded
(SNC) Architecture. The proposed SNC-NN model replaces the
conventional voltage model in RF-MRAS to form a novel MRAS
scheme named as SNC-NN-MRAS. Through simulation the proposed
SNC-NN-MRAS is shown to be promising in terms of all major
issues and robustness to parameter variation. The suitability of the
proposed SNC-NN-MRAS based speed estimator and its advantages
over RF-MRAS for sensor-less induction motor drives is
comprehensively presented through extensive simulations.