Abstract: Seismic isolation can be used as a retrofit method for historical buildings with the advantage that minimum intervention on super-structure is required. However, selection of isolation devices depends on weight and stiffness of upper structure. In this study, two buildings are considered for analyses to evaluate the applicability of this retrofitting methodology. Both buildings are located at Akita prefecture in the north part of Japan. One building is a wooden structure that corresponds to the old council meeting hall of Noshiro city. The second building is a brick masonry structure that was used as house of a foreign mining engineer and it is located at Ani town. Ambient vibration measurements were performed on both buildings to estimate their dynamic characteristics. Then, target period of vibration of isolated systems is selected as 3 seconds is selected to estimate required stiffness of isolation devices. For wooden structure, which is a light construction, it was found that natural rubber isolators in combination with friction bearings are suitable for seismic isolation. In case of masonry building elastomeric isolator can be used for its seismic isolation. Lumped mass systems are used for seismic response analysis and it is verified in both cases that seismic isolation can be used as retrofitting method of historical construction. However, in the case of the light building, most of the weight corresponds to the reinforced concrete slab that is required to install isolation devices.
Abstract: Structural failure is caused mainly by damage that
often occurs on structures. Many researchers focus on to obtain very
efficient tools to detect the damage in structures in the early state. In
the past decades, a subject that has received considerable attention in
literature is the damage detection as determined by variations in the
dynamic characteristics or response of structures. The study presents
a new damage identification technique. The technique detects the
damage location for the incomplete structure system using output
data only. The method indicates the damage based on the free
vibration test data by using ‘Two Points Condensation (TPC)
technique’. This method creates a set of matrices by reducing the
structural system to two degrees of freedom systems. The current
stiffness matrices obtain from optimization the equation of motion
using the measured test data. The current stiffness matrices compare
with original (undamaged) stiffness matrices. The large percentage
changes in matrices’ coefficients lead to the location of the damage. TPC technique is applied to the experimental data of a simply
supported steel beam model structure after inducing thickness change
in one element, where two cases consider. The method detects the
damage and determines its location accurately in both cases. In
addition, the results illustrate these changes in stiffness matrix can be
a useful tool for continuous monitoring of structural safety using
ambient vibration data. Furthermore, its efficiency proves that this
technique can be used also for big structures.
Abstract: The elastic period has a primary role in the seismic
assessment of buildings. Reliable calculations and/or estimates of the
fundamental frequency of a building and its site are essential during
analysis and design process. Various code formulas based on
empirical data are generally used to estimate the fundamental
frequency of a structure. For existing structures, in addition to code
formulas and available analytical tools such as modal analyses,
various methods of testing including ambient and forced vibration
testing procedures may be used to determine dynamic characteristics.
In this study, the dynamic properties of the 32 buildings located in
the Madinah of Saudi Arabia were identified using ambient motions
recorded at several, spatially-distributed locations within each
building. Ambient vibration measurements of buildings have been
analyzed and the fundamental longitudinal and transverse periods for
all tested buildings are presented. The fundamental mode of vibration
has been compared in plots with codes formulae (Saudi Building
Code, EC8, and UBC1997). The results indicate that measured
periods of existing buildings are shorter than that given by most
empirical code formulas. Recommendations are given based on the
common design and construction practice in Madinah city.
Abstract: Early pre-code reinforced concrete structures present
undetermined resistance to earthquakes. This situation is particularly
unacceptable in the case of essential structures, such as healthcare
structures and pilgrims' houses. Amongst these, an existing old RC
building in Madinah city (KSA) is seismically evaluated with and
without infill wall and their dynamic characteristics are compared
with measured values in the field using ambient vibration
measurements (AVM). After updating the mathematical models for
this building with the experimental results, three dimensional
pushover analysis (Nonlinear static analysis) was carried out using
commercial structural analysis software incorporating inelastic
material properties for concrete, infill and steel. The purpose of this
analysis is to evaluate the expected performance of structural systems
by estimating, strength and deformation demands in design, and
comparing these demands to available capacities at the performance
levels of interest. The results summarized and discussed.