Abstract: In CMOS integrated circuit design there is a trade-off between static power consumption and technology scaling. Recently, the power density has increased due to combination of higher clock speeds, greater functional integration, and smaller process geometries. As a result static power consumption is becoming more dominant. This is a challenge for the circuit designers. However, the designers do have a few methods which they can use to reduce this static power consumption. But all of these methods have some drawbacks. In order to achieve lower static power consumption, one has to sacrifice design area and circuit performance. In this paper, we propose a new method to reduce static power in the CMOS VLSI circuit using Variable Body Biasing technique without being penalized in area requirement and circuit performance.
Abstract: The fault current levels through the electric devices
have a significant impact on failure probability. New fault current
results in exceeding the rated capacity of circuit breaker and switching
equipments and changes operation characteristic of overcurrent relay.
In order to solve these problems, SFCL (Superconducting Fault
Current Limiter) has rising as one of new alternatives so as to improve
these problems. A fault current reduction differs depending on
installed location. Therefore, a location of SFCL is very important.
Also, SFCL decreases the fault current, and it prevents surrounding
protective devices to be exposed to fault current, it then will bring a
change of reliability. In this paper, we propose method which
determines the optimal location when SFCL is installed in power
system. In addition, the reliability about the power system which
SFCL was installed is evaluated. The efficiency and effectiveness of
this method are also shown by numerical examples and the reliability
indices are evaluated in this study at each load points. These results
show a reliability change of a system when SFCL was installed.
Abstract: The early diagnostic decision making in industrial processes is absolutely necessary to produce high quality final products. It helps to provide early warning for a special event in a process, and finding its assignable cause can be obtained. This work presents a hybrid diagnostic schmes for batch processes. Nonlinear representation of raw process data is combined with classification tree techniques. The nonlinear kernel-based dimension reduction is executed for nonlinear classification decision boundaries for fault classes. In order to enhance diagnosis performance for batch processes, filtering of the data is performed to get rid of the irrelevant information of the process data. For the diagnosis performance of several representation, filtering, and future observation estimation methods, four diagnostic schemes are evaluated. In this work, the performance of the presented diagnosis schemes is demonstrated using batch process data.
Abstract: Each new semiconductor technology node
brings smaller transistors and wires. Although this makes
transistors faster, wires get slower. In nano-scale regime, the
standard copper (Cu) interconnect will become a major hurdle
for FPGA interconnect due to their high resistivity and
electromigration. This paper presents the comprehensive
evaluation of mixed CNT bundle interconnects and
investigates their prospects as energy efficient and high speed
interconnect for future FPGA routing architecture. All
HSPICE simulations are carried out at operating frequency of
1GHz and it is found that mixed CNT bundle implemented in
FPGAs as interconnect can potentially provide a substantial
delay and energy reduction over traditional interconnects at
32nm process technology.
Abstract: Nowadays, the focus on renewable energy and alternative fuels has increased due to increasing oil prices, environment pollution, and also concern on preserving the nature. Biodiesel has been known as an attractive alternative fuel although biodiesel produced from edible oil is very expensive than conventional diesel. Therefore, the uses of biodiesel produced from non-edible oils are much better option. Currently Jatropha biodiesel (JBD) is receiving attention as an alternative fuel for diesel engine. Biodiesel is non-toxic, biodegradable, high lubricant ability, highly renewable, and its use therefore produces real reduction in petroleum consumption and carbon dioxide (CO2) emissions. Although biodiesel has many advantages, but it still has several properties need to improve, such as lower calorific value, lower effective engine power, higher emission of nitrogen oxides (NOX) and greater sensitivity to low temperature. Exhaust gas recirculation (EGR) is effective technique to reduce NOX emission from diesel engines because it enables lower flame temperature and oxygen concentration in the combustion chamber. Some studies succeeded to reduce the NOX emission from biodiesel by EGR but they observed increasing soot emission. The aim of this study was to investigate the engine performance and soot emission by using blended Jatropha biodiesel with different EGR rates. A CI engine that is water-cooled, turbocharged, using indirect injection system was used for the investigation. Soot emission, NOX, CO2, carbon monoxide (CO) were recorded and various engine performance parameters were also evaluated.
Abstract: Frequent machine breakdowns, low plant availability and increased overtime are a great threat to a manufacturing plant as they increase operating costs of an industry. The main aim of this study was to improve Overall Equipment Effectiveness (OEE) at a manufacturing company through the implementation of innovative maintenance strategies. A case study approach was used. The paper focuses on improving the maintenance in a manufacturing set up using an innovative maintenance regime mix to improve overall equipment effectiveness. Interviews, reviewing documentation and historical records, direct and participatory observation were used as data collection methods during the research. Usually production is based on the total kilowatt of motors produced per day. The target kilowatt at 91% availability is 75 Kilowatts a day. Reduced demand and lack of raw materials particularly imported items are adversely affecting the manufacturing operations. The company had to reset its targets from the usual figure of 250 Kilowatt per day to mere 75 per day due to lower availability of machines as result of breakdowns as well as lack of raw materials. The price reductions and uncertainties as well as general machine breakdowns further lowered production. Some recommendations were given. For instance, employee empowerment in the company will enhance responsibility and authority to improve and totally eliminate the six big losses. If the maintenance department is to realise its proper function in a progressive, innovative industrial society, then its personnel must be continuously trained to meet current needs as well as future requirements. To make the maintenance planning system effective, it is essential to keep track of all the corrective maintenance jobs and preventive maintenance inspections. For large processing plants these cannot be handled manually. It was therefore recommended that the company implement (Computerised Maintenance Management System) CMMS.
Abstract: The possibility of producing drinking water from
brackish ground water using Vacuum membrane distillation (VMD)
process was studied. It is a rising technology for seawater or brine
desalination process. The process simply consists of a flat sheet
hydrophobic micro porous PTFE membrane and diaphragm vacuum
pump without a condenser for the water recovery or trap. In this
work, VMD performance was investigated for aqueous NaCl solution
and natural ground water. The influence of operational parameters
such as feed flow rate (30 to 55 l/h), feed temperature (313 to 333 K),
feed salt concentration (5000 to 7000 mg/l) and permeate pressure
(1.5 to 6 kPa) on the membrane distillation (MD) permeation flux
have been investigated. The maximum flux reached to 28.34 kg/m2 h
at feed temperature, 333 K; vacuum pressure, 1.5 kPa; feed flow rate,
55 l/h and feed salt concentration, 7000 mg/l. The negligible effects
in the reduction of permeate flux found over 150 h experimental run
for salt water. But for the natural ground water application over 75 h,
scale deposits observed on the membrane surface and 29% reduction
in the permeate flux over 75 h. This reduction can be eliminated by
acidification of feed water. Hence, promote the research attention in
apply of VMD for the ground water purification over today-s
conventional RO operation.
Abstract: One of the potential and effective ways of
storing thermal energy in buildings is the integration of brick with phase change materials (PCMs). This paper presents a two-dimensional model for simulating and analyzing of PCM
in order to minimize energy consumption in the buildings. The numerical approach has been used with the real weather data of a selected city of Iran (Tehran). Two kinds of brick integrated PCM are investigated and compared base on
outdoor weather conditions and the amount of energy
consumption. The results show a significant reduction in
maximum entering heat flux to building about 32.8%
depending on PCM quantity. The results are analyzed by
various temperature contour plots. The contour plots
illustrated the time dependent mechanism of entering heat flux for a brick integrated with PCM. Further analysis is developed to investigate the effect of PCM location on the inlet heat flux. The results demonstrated that to achieve maximum performance of PCM it is better to locate PCM near the outdoor.
Abstract: The top-heavy demographic of low birth-rate and longer lifespan is a growing social problem, and one of its expected effects will be a shortage of young workers and a growing reliance on a workforce of middle-aged and older people. However, the environment of today's industrial workplace is not particularly suited to middle-aged and older workers, one notable problem being temperature control. Higher temperatures can cause health problems such as heat stroke, and the number of cases increases sharply in people over 65. Moreover, in conditions above 33°C, older people can develop circulatory system disorders, and also have a higher chance of suffering a fatal heart attack. We therefore propose a new method for controlling temperature in the indoor workplace. In this study two different verification experiments were conducted, with the proposed temperature control method being tested in cargo containers and conventional houses. The method's effectiveness was apparent in measurements of temperature and electricity consumption
Abstract: In this paper, the least-squares design of variable fractional-delay (VFD) finite impulse response (FIR) digital differentiators is proposed. The used transfer function is formulated so that Farrow structure can be applied to realize the designed system. Also, the symmetric characteristics of filter coefficients are derived, which leads to the complexity reduction by saving almost a half of the number of coefficients. Moreover, all the elements of related vectors or matrices for the optimal process can be represented in closed forms, which make the design easier. Design example is also presented to illustrate the effectiveness of the proposed method.
Abstract: Noise level has critical effects on the diagnostic
performance of signal-averaged electrocardiogram (SAECG), because
the true starting and end points of QRS complex would be masked by
the residual noise and sensitive to the noise level. Several studies and
commercial machines have used a fixed number of heart beats
(typically between 200 to 600 beats) or set a predefined noise level
(typically between 0.3 to 1.0 μV) in each X, Y and Z lead to perform
SAECG analysis. However different criteria or methods used to
perform SAECG would cause the discrepancies of the noise levels
among study subjects. According to the recommendations of 1991
ESC, AHA and ACC Task Force Consensus Document for the use of
SAECG, the determinations of onset and offset are related closely to
the mean and standard deviation of noise sample. Hence this study
would try to perform SAECG using consistent root-mean-square
(RMS) noise levels among study subjects and analyze the noise level
effects on SAECG. This study would also evaluate the differences
between normal subjects and chronic renal failure (CRF) patients in
the time-domain SAECG parameters.
The study subjects were composed of 50 normal Taiwanese and 20
CRF patients. During the signal-averaged processing, different RMS
noise levels were adjusted to evaluate their effects on three time
domain parameters (1) filtered total QRS duration (fQRSD), (2) RMS
voltage of the last QRS 40 ms (RMS40), and (3) duration of the low
amplitude signals below 40 μV (LAS40). The study results
demonstrated that the reduction of RMS noise level can increase
fQRSD and LAS40 and decrease the RMS40, and can further increase
the differences of fQRSD and RMS40 between normal subjects and
CRF patients. The SAECG may also become abnormal due to the
reduction of RMS noise level. In conclusion, it is essential to establish
diagnostic criteria of SAECG using consistent RMS noise levels for
the reduction of the noise level effects.
Abstract: Interventional cardiologists are at greater risk from
radiation exposure as a result of the procedures they undertake than
most other medical specialists. A study was performed to evaluate
operator dose during interventional cardiology procedures and to
establish methods of operator dose reduction with a radiation
protective device. Different procedure technique and use of
protective tools can explain big difference in the annual equivalent
dose received by the professionals. Strategies to prevent and
monitor radiation exposure, advanced protective shielding and
effective radiation monitoring methods should be applied.
Abstract: The approach proposed here is oriented in the direction of fuzzy system for the analysis and the synthesis of intelligent climate controllers, the simulation of the internal climate of the greenhouse is achieved by a linear model whose coefficients are obtained by identification. The use of fuzzy logic controllers for the regulation of climate variables represents a powerful way to minimize the energy cost. Strategies of reduction and optimization are adopted to facilitate the tuning and to reduce the complexity of the controller.
Abstract: This study was conducted to determine the
effect of abdominal exercises versus abdominal supporting
belt on abdominal efficiency and inter-recti separation
following vaginal delivery.30 primiparous post-natal women
participated in this study. Their age ranged from (25 - 35)
years and their BMI < 30 Kg/m2. Participants were assigned
randomly into 2groups, participants of group (A) used
abdominal belt from the 2nd day following delivery, till the end
of puerperium (6 weeks), while participants of group (B)
engaged into abdominal exercises program from the 2nd day
following delivery for 6 weeks. The results of the present
study revealed that although there was no statistical difference
in waist circumference between both groups, participation in
abdominal exercise program produced a pronounced reduction
in waist/hip ratio, and inter-recti separation and also caused
significant increase in abdominal muscles strength (peak
torque, maximum repetition total work and average power)
higher than the use of abdominal belt.
Abstract: Five vegetables (spinach, lettuce, cabbage, tomato, and onion) were freshly harvested from the Alau Dam and Gongulong agricultural areas for the determination of some organochlorine pesticide residues (o, p-DDE, p,p’-DDD, o,p’-DDD, p,p’-DDT, α-BHC, γ-BHC, metoxichlor, lindane, endosulfan dieldrin, and aldrin.) Soil samples were also collected at different depths for the determination of the above pesticides. Samples collection and preparation were conducted using standard procedures. The concentrations of all the pesticides in the soil and vegetable samples were determined using GC/MS SHIMADZU (GC-17A) equipped with electron capture detector (ECD). The highest concentration was that of p,p’-DDD (132.4±13.45µg/g) which was observed in the leaf of cabbage, while the lowest concentration was that of p,p’-DDT (2.34µg/g) was observed in the root of spinach. Similar trends were observed at the Gongulong agricultural area, with p,p’-DDD having the highest concentration of 153.23µg/g in the leaf of cabbage, while the lowest concentration was that of p,p’-DDT (12.45µg/g) which was observed in the root of spinach. α-BHC, γ-BHC, Methoxychlor, and lindane were detected in all the vegetable samples studied. The concentrations of all the pesticides in the soil samples were observed to be higher at a depth of 21-30cm, while the lowest concentrations were observed at a depth of 0-10cm. The concentrations of all the pesticides in the vegetables and soil samples from the two agricultural sites were observed to be at alarming levels, much higher than the maximum residue limits (MRLs) and acceptable daily intake values (ADIs) .The levels of the pesticides observed in the vegetables and soil samples investigated, are of such a magnitude that calls for special attention and laws to regulate the use and circulation of such chemicals. Routine monitoring of pesticide residues in these study areas is necessary for the prevention, control and reduction of environmental pollution, so as to minimize health risks.
Abstract: In this paper, a new encoding algorithm of spectral envelope based on NLMS in G.729.1 for VoIP is proposed. In the TDAC part of G.729.1, the spectral envelope and MDCT coefficients extracted in the weighted CELP coding error (lower-band) and the higher-band input signal are encoded. In order to reduce allocation bits for spectral envelope coding, a new quantization algorithm based on NLMS is proposed. Also, reduced bits are used to enhance sound quality. The performance of the proposed algorithm is evaluated by sound quality and bit reduction rates in clean and frame loss conditions.
Abstract: The general idea behind the filter is to average a pixel
using other pixel values from its neighborhood, but simultaneously to
take care of important image structures such as edges. The main
concern of the proposed filter is to distinguish between any variations
of the captured digital image due to noise and due to image structure.
The edges give the image the appearance depth and sharpness. A
loss of edges makes the image appear blurred or unfocused.
However, noise smoothing and edge enhancement are traditionally
conflicting tasks. Since most noise filtering behaves like a low pass
filter, the blurring of edges and loss of detail seems a natural
consequence. Techniques to remedy this inherent conflict often
encompass generation of new noise due to enhancement.
In this work a new fuzzy filter is presented for the noise reduction
of images corrupted with additive noise. The filter consists of three
stages. (1) Define fuzzy sets in the input space to computes a fuzzy
derivative for eight different directions (2) construct a set of IFTHEN
rules by to perform fuzzy smoothing according to
contributions of neighboring pixel values and (3) define fuzzy sets in
the output space to get the filtered and edged image.
Experimental results are obtained to show the feasibility of the
proposed approach with two dimensional objects.
Abstract: In this research we show that the dynamics of an action potential in a cell can be modeled with a linear combination of the dynamics of the gating state variables. It is shown that the modeling error is negligible. Our findings can be used for simplifying cell models and reduction of computational burden i.e. it is useful for simulating action potential propagation in large scale computations like tissue modeling. We have verified our finding with the use of several cell models.
Abstract: The purpose of this study is to introduce a new
interface program to calculate a dose distribution with Monte Carlo method in complex heterogeneous systems such as organs or tissues
in proton therapy. This interface program was developed under
MATLAB software and includes a friendly graphical user interface
with several tools such as image properties adjustment or results display. Quadtree decomposition technique was used as an image
segmentation algorithm to create optimum geometries from Computed Tomography (CT) images for dose calculations of proton
beam. The result of the mentioned technique is a number of nonoverlapped
squares with different sizes in every image. By this way
the resolution of image segmentation is high enough in and near
heterogeneous areas to preserve the precision of dose calculations
and is low enough in homogeneous areas to reduce the number of
cells directly. Furthermore a cell reduction algorithm can be used to combine neighboring cells with the same material. The validation of this method has been done in two ways; first, in comparison with experimental data obtained with 80 MeV proton beam in Cyclotron
and Radioisotope Center (CYRIC) in Tohoku University and second, in comparison with data based on polybinary tissue calibration method, performed in CYRIC. These results are presented in this paper. This program can read the output file of Monte Carlo code while region of interest is selected manually, and give a plot of dose distribution of proton beam superimposed onto the CT images.
Abstract: Multi-user interference (MUI) is the main reason of system deterioration in the Spectral Amplitude Coding Optical Code Division Multiple Access (SAC-OCDMA) system. MUI increases with the number of simultaneous users, resulting into higher probability bit rate and limits the maximum number of simultaneous users. On the other hand, Phase induced intensity noise (PIIN) problem which is originated from spontaneous emission of broad band source from MUI severely limits the system performance should be addressed as well. Since the MUI is caused by the interference of simultaneous users, reducing the MUI value as small as possible is desirable. In this paper, an extensive study for the system performance specified by MUI and PIIN reducing is examined. Vectors Combinatorial (VC) codes families are adopted as a signature sequence for the performance analysis and a comparison with reported codes is performed. The results show that, when the received power increases, the PIIN noise for all the codes increases linearly. The results also show that the effect of PIIN can be minimized by increasing the code weight leads to preserve adequate signal to noise ratio over bit error probability. A comparison study between the proposed code and the existing codes such as Modified frequency hopping (MFH), Modified Quadratic- Congruence (MQC) has been carried out.