Abstract: This paper presents an analysis study on the impacts
of the changes of the capacitor banks, the loss of a transformer, and
the installation of distributed generation on the voltage total harmonic
distortion and harmonic resonance. The study is applied in a real
system in Oman, Sohar Industrial Port–C Substation Network.
Frequency scan method and Fourier series analysis method are used
with the help of EDSA software. Moreover, the results are compared
with limits specified by national Oman distribution code.
Abstract: Flue gas desulfurization gypsum (FGD) is a waste
material arouse from coal power plants. Hydroxyapatite (HAP) is a
biomaterial with porous structure. In this study, FGD gypsum which
retrieved from coal power plant in Turkey was characterized and
HAP particles which can be used as an adsorbent in wastewater
treatment application were synthesized from the FGD gypsum. The
raw materials are characterized by using X Ray Diffraction (XRD)
and Fourier transform infrared spectroscopy (FT-IR) techniques and
produced HAP are characterized by using XRD. As a result, HAP
particles were synthesized at the molar ratio of 5:10, 5:15, 5:20, 5:24,
at room temperature, in alkaline medium (pH=11) and in 1 hour-reaction
time. Among these conditions, 5:20 had the best result.
Abstract: Device-to-device (D2D) communication is considered a
promising technique to provide wireless peer-to-peer communication
services. Due to increasing demand on mobile services, available
spectrum for radio frequency (RF) based communications becomes
scarce. Recently, visible light communications (VLC) has evolved
as a high speed wireless data transmission technology for indoor
environments with abundant available bandwidth. In this paper,
a novel VLC based D2D communication that provides wireless
peer-to-peer communication is proposed. Potential low operating
power devices for an efficient D2D communication over increasing
distance of separation between devices is analyzed. Optical repeaters
(OR) are also proposed to enhance the performance in an environment
where direct D2D communications yield degraded performance.
Simulation results show that VLC plays an important role in
providing efficient D2D communication up to a distance of 1 m
between devices. It is also found that the OR significantly improves
the coverage distance up to 3.5 m.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: The power buck converter is the most widely used
DC/DC converter topology. They have a very large application area
such as DC motor drives, photovoltaic power system which require
fast transient responses and high efficiency over a wide range of load
current. This work proposes, the modelling of DC/DC power buck
converter using state-space averaging method and the current-mode
control using a proportional-integral controller. The efficiency of the
proposed model and control loop are evaluated with operating point
changes. The simulation results proved the effectiveness of the linear
model of DC/DC power buck converter.
Abstract: The aim of this research is to understand how the
emerging power bloc BRICS employs infrastructure development
narratives to construct a new world order. BRICS is an international
body consisting of five emerging countries that collaborate on
economic and political issues: Brazil, Russia, India, China, and South
Africa. This study explores the projection of infrastructure
development narratives through an analysis of BRICS’ attention to
infrastructure investment and financing, its support of the New
Partnership on African Development and the establishment of the
New Development Bank in Shanghai. The theory of Strategic
Narratives is used to explore BRICS’ commitment to infrastructure
development and to distinguish three layers: system narratives
(BRICS as a global actor to propose development reform), identity
narratives (BRICS as a collective identity joining efforts to act upon
development aspirations) and issue narratives (BRICS committed to a
range of issues of which infrastructure development is prominent).
The methodology that is employed is a narrative analysis of BRICS’
official documents, media statements, and website imagery. A
comparison of these narratives illuminates tensions at the three layers
and among the five member states. Identifying tensions among
development infrastructure narratives provides an indication of how
policymaking for infrastructure development could be improved.
Subsequently, it advances BRICS’ ability to act as a global actor to
construct a new world order.
Abstract: This paper investigates the effects of breaks in bonds,
breaks in the earthing system and breaks in earth wire on the rise of
the earth potential (EPR) in a substation and at the transmission tower
bases using various models of an L6 tower. Different approaches
were adopted to examine the integrity of the earthing system and the
terminal towers. These effects were investigated to see the associated
difference in the EPR magnitudes with respect to a healthy system at
various locations. Comparisons of the computed EPR magnitudes
were then made between the healthy and unhealthy system to detect
any difference. The studies were conducted at power frequency for a
uniform soil with different soil resistivities. It was found that full
breaks in the double bond of the terminal towers increase the EPR
significantly at the fault location, while they reduce EPR at the
terminal tower bases. A fault on the isolated section of the grid can
result in EPR values up to 8 times of those on a healthy system at
higher soil resistivities, provided that the extended earthing system
stays connected to the grid.
Abstract: Interaction between mixing and crystallization is often
ignored despite the fact that it affects almost every aspect of the
operation including nucleation, growth, and maintenance of the
crystal slurry. This is especially pronounced in multiple impeller
systems where flow complexity is increased. By choosing proper
mixing parameters, what closely depends on the knowledge of the
hydrodynamics in a mixing vessel, the process of batch cooling
crystallization may considerably be improved. The values that render
useful information when making this choice are mixing time and
power consumption. The predominant motivation for this work was
to investigate the extent to which radial dual impeller configuration
influences mixing time, power consumption and consequently the
values of metastable zone width and nucleation rate. In this research,
crystallization of borax was conducted in a 15 dm3 baffled batch
cooling crystallizer with an aspect ratio (H/T) of 1.3. Mixing was
performed using two straight blade turbines (4-SBT) mounted on the
same shaft that generated radial fluid flow. Experiments were
conducted at different values of N/NJS ratio (impeller speed/
minimum impeller speed for complete suspension), D/T ratio
(impeller diameter/crystallizer diameter), c/D ratio (lower impeller
off-bottom clearance/impeller diameter), and s/D ratio (spacing
between impellers/impeller diameter). Mother liquor was saturated at
30°C and was cooled at the rate of 6°C/h. Its concentration was
monitored in line by Na-ion selective electrode. From the values of
supersaturation that was monitored continuously over process time, it
was possible to determine the metastable zone width and
subsequently the nucleation rate using the Mersmann’s nucleation
criterion. For all applied dual impeller configurations, the mixing
time was determined by potentiometric method using a pulse
technique, while the power consumption was determined using a
torque meter produced by Himmelstein & Co. Results obtained in
this investigation show that dual impeller configuration significantly
influences the values of mixing time, power consumption as well as
the metastable zone width and nucleation rate. A special attention
should be addressed to the impeller spacing considering the flow
interaction that could be more or less pronounced depending on the
spacing value.
Abstract: Smart metering and demand response are gaining
ground in industrial and residential applications. Smart Appliances
have been given concern towards achieving Smart home. The success
of Smart grid development relies on the successful implementation of
Information and Communication Technology (ICT) in power sector.
Smart Appliances have been the technology under development and
many new contributions to its realization have been reported in the
last few years. The role of ICT here is to capture data in real time,
thereby allowing bi-directional flow of information/data between
producing and utilization point; that lead a way for the attainment of
Smart appliances where home appliances can communicate between
themselves and provide a self-control (switch on and off) using the
signal (information) obtained from the grid. This paper depicts the
background on ICT for smart appliances paying a particular attention
to the current technology and identifying the future ICT trends for
load monitoring through which smart appliances can be achieved to
facilitate an efficient smart home system which promote demand
response program. This paper grouped and reviewed the recent
contributions, in order to establish the current state of the art and
trends of the technology, so that the reader can be provided with a
comprehensive and insightful review of where ICT for smart
appliances stands and is heading to. The paper also presents a brief
overview of communication types, and then narrowed the discussion
to the load monitoring (Non-intrusive Appliances Load Monitoring
‘NALM’). Finally, some future trends and challenges in the further
development of the ICT framework are discussed to motivate future
contributions that address open problems and explore new
possibilities.
Abstract: Voltage level must be raised in order to deliver the
produced energy to the consumption zones with less loss and less
cost. Power transformers used to raise or lower voltage are important
parts of the energy transmission system. Power transformers used in
switchgear and power generation plants stay in human's intensive
habitat zones as a result of expanding cities. Accordingly, noise
levels produced by power transformers have begun more and more
important and they have established itself as one of the research field.
In this research, the noise cause on transformers has been
investigated, it's causes has been examined and noise measurement
techniques have been introduced. Examples of transformer noise test
results are submitted and precautions to be taken were discussed for
the purpose of decreasing of the noise which will occurred by
transformers.
Abstract: While the feature sizes of recent Complementary Metal
Oxid Semiconductor (CMOS) devices decrease the influence of static
power prevails their energy consumption. Thus, power savings that
benefit from Dynamic Frequency and Voltage Scaling (DVFS) are
diminishing and temporal shutdown of cores or other microchip
components become more worthwhile. A consequence of powering off unused parts of a chip is that the
relative difference between idle and fully loaded power consumption
is increased. That means, future chips and whole server systems gain
more power saving potential through power-aware load balancing,
whereas in former times this power saving approach had only
limited effect, and thus, was not widely adopted. While powering
off complete servers was used to save energy, it will be superfluous
in many cases when cores can be powered down. An important
advantage that comes with that is a largely reduced time to respond
to increased computational demand. We include the above developments in a server power model
and quantify the advantage. Our conclusion is that strategies from
datacenters when to power off server systems might be used in the
future on core level, while load balancing mechanisms previously
used at core level might be used in the future at server level.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: This paper describes a simple way to control the speed
of PMBLDC motor using Fuzzy logic control method. In the
conventional PI controller the performance of the motor system is
simulated and the speed is regulated by using PI controller. These
methods used to improve the performance of PMSM drives, but in
some cases at different operating conditions when the dynamics of
the system also vary over time and it can change the reference speed,
parameter variations and the load disturbance. The simulation is
powered with the MATLAB program to get a reliable and flexible
simulation. In order to highlight the effectiveness of the speed control
method the FLC method is used. The proposed method targeted in
achieving the improved dynamic performance and avoids the
variations of the motor drive. This drive has high accuracy, robust
operation from near zero to high speed. The effectiveness and
flexibility of the individual techniques of the speed control method
will be thoroughly discussed for merits and demerits and finally
verified through simulation and experimental results for comparative
analysis.
Abstract: In this paper, the regression dependence of dancing
intensity from wind speed and length of span was established due to
the statistic data obtained from multi-year observations on line wires
dancing accumulated by power systems of Kazakhstan and the
Russian Federation. The lower and upper limitations of the equations
parameters were estimated, as well as the adequacy of the regression
model. The constructed model will be used in research of dancing
phenomena for the development of methods and means of protection
against dancing and for zoning plan of the territories of line wire
dancing.
Abstract: In this study, the potential benefits of playing action
video game among congenitally deaf and dumb subjects is reported in
terms of EEG ratio indices. The frontal and occipital lobes are
associated with development of motor skills, cognition, and visual
information processing and color recognition. The sixteen hours of
First-Person shooter action video game play resulted in the increase
of the ratios β/(α+θ) and β/θ in frontal and occipital lobes. This can
be attributed to the enhancement of certain aspect of cognition among
deaf and dumb subjects.
Abstract: This paper presents the performance characteristics of
Darrieus-type vertical axis wind turbine (VAWT) with NACA airfoil
blades. The performance of Darrieus-type VAWT can be
characterized by torque and power. There are various parameters
affecting the performance such as chord length, helical angle, pitch
angle and rotor diameter. To estimate the optimum shape of Darrieustype
wind turbine in accordance with various design parameters, we
examined aerodynamic characteristics and separated flow occurring
in the vicinity of blade, interaction between flow and blade, and
torque and power characteristics derived from it. For flow analysis,
flow variations were investigated based on the unsteady RANS
(Reynolds-averaged Navier-Stokes) equation. Sliding mesh algorithm
was employed in order to consider rotational effect of blade. To
obtain more realistic results we conducted experiment and numerical
analysis at the same time for three-dimensional shape. In addition,
several parameters (chord length, rotor diameter, pitch angle, and
helical angle) were considered to find out optimum shape design and
characteristics of interaction with ambient flow. Since the NACA
airfoil used in this study showed significant changes in magnitude of
lift and drag depending on an angle of attack, the rotor with low drag,
long cord length and short diameter shows high power coefficient in
low tip speed ratio (TSR) range. On the contrary, in high TSR range,
drag becomes high. Hence, the short-chord and long-diameter rotor
produces high power coefficient. When a pitch angle at which airfoil
directs toward inside equals to -2° and helical angle equals to 0°,
Darrieus-type VAWT generates maximum power.
Abstract: Many cluster based routing protocols have been
proposed in the field of wireless sensor networks, in which a group of
nodes are formed as clusters. A cluster head is selected from one
among those nodes based on residual energy, coverage area, number
of hops and that cluster-head will perform data gathering from
various sensor nodes and forwards aggregated data to the base station
or to a relay node (another cluster-head), which will forward the
packet along with its own data packet to the base station. Here a
Game Theory based Diligent Energy Utilization Algorithm (GTDEA)
for routing is proposed. In GTDEA, the cluster head selection is done
with the help of game theory, a decision making process, that selects
a cluster-head based on three parameters such as residual energy
(RE), Received Signal Strength Index (RSSI) and Packet Reception
Rate (PRR). Finding a feasible path to the destination with minimum
utilization of available energy improves the network lifetime and is
achieved by the proposed approach. In GTDEA, the packets are
forwarded to the base station using inter-cluster routing technique,
which will further forward it to the base station. Simulation results
reveal that GTDEA improves the network performance in terms of
throughput, lifetime, and power consumption.
Abstract: Creativity is marked by the ability or power, to
produce through imaginative skill and create something anew. The
University is one of the great places to improve the talent in
imaginative skill. The purpose of this study was to identify a
creativity of the student in presentation product development. Two
hundred seventeen Technical and Vocational Education (TVE)
students in Universiti Tun Hussein Onn had chosen as a respondent.
This study is to survey the level of creativity which is focused on
knowledge, skills, presentation style, and character of creative
personnel. The level of creativity was measured based on the scale at
low, medium and high followed by mean score level. The data
collected by questionnaire, then analyzed using SPSS version
20.0.The result of the study indicated that the students showed a
higher of creativity (mean score in Knowledge = 4.12 and Skills=
4.02). In conjunction with the findings, implications and
recommendations were suggested forward like to ensconce the
research and improve with a more creativity concept in presentation
product of development for learning and teaching process.
Abstract: Orthogonal Frequency Division Multiplexing
(OFDM) has been used in many advanced wireless communication
systems due to its high spectral efficiency and robustness to
frequency selective fading channels. However, the major concern
with OFDM system is the high peak-to-average power ratio (PAPR)
of the transmitted signal. Some of the popular techniques used for
PAPR reduction in OFDM system are conventional partial transmit
sequences (CPTS) and clipping. In this paper, a parallel
combination/hybrid scheme of PAPR reduction using clipping and
CPTS algorithms is proposed. The proposed method intelligently
applies both the algorithms in order to reduce both PAPR as well as
computational complexity. The proposed scheme slightly degrades
bit error rate (BER) performance due to clipping operation and it can
be reduced by selecting an appropriate value of the clipping ratio
(CR). The simulation results show that the proposed algorithm
achieves significant PAPR reduction with much reduced
computational complexity.
Abstract: An Energetic and exergetic analysis is conducted on a
Steam Turbine Power Plant of an existing Phosphoric Acid Factory.
The heat recovery systems used in different parts of the plant are also
considered in the analysis. Mass, thermal and exergy balances are
established on the main compounds of the factory. A numerical code
is established using EES software to perform the calculations
required for the thermal and exergy plant analysis. The effects of the
key operating parameters such as steam pressure and temperature,
mass flow rate as well as seawater temperature, on the cycle
performances are investigated. A maximum Exergy Loss Rate of about 72% is obtained for the
melters, followed by the condensers, heat exchangers and the pumps.
The heat exchangers used in the phosphoric acid unit present
exergetic efficiencies around 33% while 60% to 72% are obtained for
steam turbines and blower. For the explored ranges of HP steam
temperature and pressure, the exergy efficiencies of steam turbine
generators STGI and STGII increase of about 2.5% and 5.4%
respectively. In the same way optimum HP steam flow rate values,
leading to the maximum exergy efficiencies are defined.