Abstract: Since 2005, an SRF module of CESR type serves as the
accelerating cavity at the Taiwan Light Source in the National
Synchrotron Radiation Research Center. A 500-MHz niobium cavity
is immersed in liquid helium inside this SRF module. To reduce heat
load, the liquid helium vessel is thermally shielded by
liquid-nitrogen-cooled copper layer, and the beam chambers are also
anchored with pipes of the liquid nitrogen flow in middle of the liquid
helium vessel and the vacuum vessel. A strong correlation of the
movement of the cavity-s frequency tuner with the temperature
variation of parts cooled with liquid nitrogen was observed. A
previous study on a spare SRF module with the niobium cavity cooled
by liquid nitrogen instead of liquid helium, satisfactory suppression of
the thermal oscillation was achieved by attaching a temporary buffer
tank for the vented shielding nitrogen flow from the SRF module. In
this study, a home-made buffer tank is designed and integrated to the
spare SRF module with cavity cooled by liquid helium. Design,
construction, integration, and preliminary test results of this buffer
tank are presented.
Abstract: This work proposes an accurate crosstalk noise estimation method in the presence of multiple RLC lines for the use in design automation tools. This method correctly models the loading effects of non switching aggressors and aggressor tree branches using resistive shielding effect and realistic exponential input waveforms. Noise peak and width expressions have been derived. The results obtained are at good agreement with SPICE results. Results show that average error for noise peak is 4.7% and for the width is 6.15% while allowing a very fast analysis.
Abstract: Today with the rapid growth of telecommunications equipment, electronic and developing more and more networks of power, influence of electromagnetic waves on one another has become hot topic discussions. So in this article, this issue and appropriate mechanisms for EMC operations have been presented. First, impact of high voltage lines on the surrounding environment especially on the control room has been investigated, then to reduce electromagnetic radiation, various methods of shielding are provided and shielding effectiveness of them has been compared. It should be expressed that simulations have been done by the finite element method (FEM).
Abstract: A transient finite element model has been developed
to study the heat transfer and fluid flow during spot Gas Tungsten
Arc Welding (GTAW) on stainless steel. Temperature field, fluid
velocity and electromagnetic fields are computed inside the cathode,
arc-plasma and anode using a unified MHD formulation. The
developed model is then used to study the influence of different
helium-argon gas mixtures on both the energy transferred to the
workpiece and the time evolution of the weld pool dimensions. It is
found that the addition of helium to argon increases the heat flux
density on the weld axis by a factor that can reach 6.5. This induces
an increase in the weld pool depth by a factor of 3. It is also found
that the addition of only 10% of argon to helium decreases
considerably the weld pool depth, which is due to the electrical
conductivity of the mixture that increases significantly when argon is
added to helium.
Abstract: Nowadays, there is little information, concerning the
heat shield systems, and this information is not completely reliable to
use in so many cases. for example, the precise calculation cannot be
done for various materials. In addition, the real scale test has two
disadvantages: high cost and low flexibility, and for each case we
must perform a new test. Hence, using numerical modeling program
that calculates the surface recession rate and interior temperature
distribution is necessary. Also, numerical solution of governing
equation for non-charring material ablation is presented in order to
anticipate the recession rate and the heat response of non-charring
heat shields. the governing equation is nonlinear and the Newton-
Rafson method along with TDMA algorithm is used to solve this
nonlinear equation system. Using Newton- Rafson method for
solving the governing equation is one of the advantages of the
solving method because this method is simple and it can be easily
generalized to more difficult problems. The obtained results
compared with reliable sources in order to examine the accuracy of
compiling code.
Abstract: Thyroid cancer-s overall contribution to the
worldwide cancer burden is relatively small, but incidence rates have increased over the last three decades throughout the world. This trend has been hypothesised to reflect a combination of technological advances enabling increased detection, but also changes in
environmental factors, including population exposure to ionising radiation from fallout, diagnostic tests and treatment for benign and
malignant conditions. The Thyroid dose received apparently shielded
by cerrobend blocks was about 8cGy in 100cGy Expose
Abstract: The scope of this paper is to describe a real electrical
installation of renewable energy using photovoltaic cells. The
displayed power grid connected network was established in 2007 at
area of Northern Greece. The photovoltaic park is composed of 6120
photovoltaic cells able to deliver a total power of 1.101.600 Wp. For
the transformation of DC voltage to AC voltage have been used 25
stand alone three phases inverters and for the connection at the
medium voltage network of Greek Power Authority have been
installed two oil immersed transformer of 630 kVA each one. Due to
the wide space area of installation a specific external lightning
protection system has been designed. Additionally, due to the
sensitive electronics of the control and protection systems of park,
surge protection, equipotent bonding and shielding were also of
major importance.
Abstract: A power cable is widely used for power supply in
power distributing networks and power transmission lines. Due to
limitations in the production, delivery and setting up power cables,
they are produced and delivered in several separate lengths. Cable
itself, consists of two cable terminations and arbitrary number of
cable joints, depending on the cable route length. Electrical stress
control is needed to prevent a dielectric breakdown at the end of the
insulation shield in both the air and cable insulation. Reliability of
cable joint depends on its materials, design, installation and operating
environment. The paper describes design and performance results for
new modeled cable joints. Design concepts, based on numerical
calculations, must be correct. An Equivalent Electrodes
Method/Boundary Elements Method-hybrid approach that allows
electromagnetic field calculations in multilayer dielectric media,
including inhomogeneous regions, is presented.
Abstract: The design of methods of the 20 K large dimension cold shield used for infrared radiation demarcating in space environment simulation test were introduced in this paper. The cold shield were cooled by five G-M cryocoolers , and the dimension of the cold shield is the largest in our country.Cold shield installation and distribution and compensator for contraction on cooling were introduced detailedly. The temperature distribution and cool-down time of cold shield surface were also calculated and analysed in this paper. The design of cold shield resolves the difficulty of compensator for contraction on cooling successfully. Test results show that the actual technical performance indicators of cold shield met and exceeded the design requirements.
Abstract: Multi-site damage (MSD) has been a challenge to
aircraft, civil and power plant structures. In real life components are subjected to cracking at many vulnerable locations such as the bolt
holes. However, we do not consider for the presence of multiple cracks. Unlike components with a single crack, these components are
difficult to predict. When two cracks approach one another, their
stress fields influence each other and produce enhancing or shielding effect depending on the position of the cracks. In the present study,
numerical studies on fracture analysis have been conducted by using
the developed code based on the modified virtual crack closure integral (MVCCI) technique and finite element analysis (FEA) software ABAQUS for computing SIF of plates with multiple cracks.
Various parametric studies have been carried out and the results have
been compared with literature where ever available and also with the solution, obtained by using ABAQUS. By conducting extensive
numerical studies expressions for SIF have been obtained for collinear cracks and non-aligned cracks.
Abstract: This article presents the simulation, parameterization and optimization of an electromagnet with the C–shaped configuration, intended for the study of magnetic properties of materials. The electromagnet studied consists of a C-shaped yoke, which provides self–shielding for minimizing losses of magnetic flux density, two poles of high magnetic permeability and power coils wound on the poles. The main physical variable studied was the static magnetic flux density in a column within the gap between the poles, with 4cm2 of square cross section and a length of 5cm, seeking a suitable set of parameters that allow us to achieve a uniform magnetic flux density of 1x104 Gaussor values above this in the column, when the system operates at room temperature and with a current consumption not exceeding 5A. By means of a magnetostatic analysis by the finite element method, the magnetic flux density and the distribution of the magnetic field lines were visualized and quantified. From the results obtained by simulating an initial configuration of electromagnet, a structural optimization of the geometry of the adjustable caps for the ends of the poles was performed. The magnetic permeability effect of the soft magnetic materials used in the poles system, such as low– carbon steel (0.08% C), Permalloy (45% Ni, 54.7% Fe) and Mumetal (21.2% Fe, 78.5% Ni), was also evaluated. The intensity and uniformity of the magnetic field in the gap showed a high dependence with the factors described above. The magnetic field achieved in the column was uniform and its magnitude ranged between 1.5x104 Gauss and 1.9x104 Gauss according to the material of the pole used, with the possibility of increasing the magnetic field by choosing a suitable geometry of the cap, introducing a cooling system for the coils and adjusting the spacing between the poles. This makes the device a versatile and scalable tool to generate the magnetic field necessary to perform magnetic characterization of materials by techniques such as vibrating sample magnetometry (VSM), Hall-effect, Kerr-effect magnetometry, among others. Additionally, a CAD design of the modules of the electromagnet is presented in order to facilitate the construction and scaling of the physical device.