Abstract: This project aims at building an efficient and
automatic power monitoring SCADA system, which is capable of
monitoring the electrical parameters of high voltage powered devices
in real time for example RMS voltage and current, frequency, energy
consumed, power factor etc. The system uses RS-485 serial
communication interface to transfer data over longer distances.
Embedded C programming is the platform used to develop two
hardware modules namely: RTU and Master Station modules, which
both use the CC2540 BLE 4.0 microcontroller configured in slave /
master mode. The Si8900 galvanic ally isolated microchip is used to
perform ADC externally. The hardware communicates via UART
port and sends data to the user PC using the USB port. Labview
software is used to design a user interface to display current state of
the power loads being monitored as well as logs data to excel
spreadsheet file. An understanding of the Si8900’s auto baud rate
process is key to successful implementation of this project.
Abstract: In recent years, a wide variety of applications are developed with Support Vector Machines -SVM- methods and Artificial Neural Networks -ANN-. In general, these methods depend on intrusion knowledge databases such as KDD99, ISCX, and CAIDA among others. New classes of detectors are generated by machine learning techniques, trained and tested over network databases. Thereafter, detectors are employed to detect anomalies in network communication scenarios according to user’s connections behavior. The first detector based on training dataset is deployed in different real-world networks with mobile and non-mobile devices to analyze the performance and accuracy over static detection. The vulnerabilities are based on previous work in telemedicine apps that were developed on the research group. This paper presents the differences on detections results between some network scenarios by applying traditional detectors deployed with artificial neural networks and support vector machines.
Abstract: Device-to-device (D2D) communication is considered a
promising technique to provide wireless peer-to-peer communication
services. Due to increasing demand on mobile services, available
spectrum for radio frequency (RF) based communications becomes
scarce. Recently, visible light communications (VLC) has evolved
as a high speed wireless data transmission technology for indoor
environments with abundant available bandwidth. In this paper,
a novel VLC based D2D communication that provides wireless
peer-to-peer communication is proposed. Potential low operating
power devices for an efficient D2D communication over increasing
distance of separation between devices is analyzed. Optical repeaters
(OR) are also proposed to enhance the performance in an environment
where direct D2D communications yield degraded performance.
Simulation results show that VLC plays an important role in
providing efficient D2D communication up to a distance of 1 m
between devices. It is also found that the OR significantly improves
the coverage distance up to 3.5 m.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: Solar water heating is a thermodynamic process of
heating water using sunlight with the help of solar water heater. Thus,
solar water heater is a device used to harness solar energy. In this
paper, a modified solar water heating system (MSWHS) has been
proposed over flat plate collector (FPC) and Evacuated tube collector
(ETC). The modifications include selection of materials other than
glass, and glass wool which are conventionally used for fabricating
FPC and ETC. Some modifications in design have also been
proposed. Its collector is made of double layer of semi-cylindrical
acrylic tubes and fibre reinforced plastic (FRP) insulation base. Water
tank is made of double layer of acrylic sheet except base and north
wall. FRP is used in base and north wall of the water tank. A concept
of equivalent thickness has been utilised for calculating the
dimensions of collector plate, acrylic tube and tank. A thermal model for the proposed design of MSWHS is developed
and simulation is carried out on MATLAB for the capacity of 200L
MSWHS having collector area of 1.6 m2, length of acrylic tubes of
2m at an inclination angle 25° which is taken nearly equal to the
latitude of the given location. Latitude of Allahabad is 24.45° N. The
results show that the maximum temperature of water in tank and tube
has been found to be 71.2°C and 73.3°C at 17:00hr and 16:00hr
respectively in March for the climatic data of Allahabad. Theoretical performance analysis has been carried out by varying
number of tubes of collector, the tank capacity and climatic data for
given months of winter and summer.
Abstract: Ultrasonic metal welding has been the subject of ongoing research and development, most recently concentrating on metal joining in miniature devices, for example to allow solder-free wire bonding. As well as at the small scale, there are also opportunities to research the joining of thicker sheet metals and to widen the range of similar and dissimilar materials that can be successfully joined using this technology. This study presents the design, characterisation and test of a lateral-drive ultrasonic metal spot welding device. The ultrasonic metal spot welding horn is modelled using finite element analysis (FEA) and its vibration behaviour is characterised experimentally to ensure ultrasonic energy is delivered effectively to the weld coupon. The welding stack and fixtures are then designed and mounted on a test machine to allow a series of experiments to be conducted for various welding and ultrasonic parameters. Weld strength is subsequently analysed using tensile-shear tests. The results show how the weld strength is particularly sensitive to the combination of clamping force and ultrasonic vibration amplitude of the welding tip, but there are optimal combinations of these and also limits that must be clearly identified.
Abstract: Centrifugal-casting machine is used in manufacturing
special machine components like multi-layer journal bearing used in
all internal combustion engine, steam, gas turbine and air craft turboengine
where isotropic properties and high precisions are desired.
Moreover, this machine can be used in manufacturing thin wall hightech
machine components like cylinder liners and piston rings of IC
engine and other machine parts like sleeves, and bushes. Heavy-duty
machine component like railway wheel can also be prepared by
centrifugal casting. A lot of technological developments are required
in casting process for production of good casted machine body and
machine parts. Usually defects like blowholes, surface roughness,
chilled surface etc. are found in sand casted machine parts. But these
can be removed by centrifugal casting machine using rotating
metallic die. Moreover, die rotation, its temperature control, and good
pouring practice can contribute to the quality of casting because of
the fact that the soundness of a casting in large part depends upon
how the metal enters into the mold or dies and solidifies. Poor
pouring practice leads to variety of casting defects such as
temperature loss, low quality casting, excessive turbulence, over
pouring etc. Besides these, handling of molten metal is very
unsecured and dangerous for the workers. In order to get rid of all
these problems, the need of an automatic pouring device arises. In
this research work, a robot assisted pouring device and a centrifugal
casting machine are designed, developed constructed and tested
experimentally which are found to work satisfactorily. The robot
assisted pouring device is further modified and developed for using it
in actual metal casting process. Lot of settings and tests are required
to control the system and ultimately it can be used in automation of
centrifugal casting machine to produce high-tech machine parts with
desired precision.
Abstract: Cloud computing can reduce the start-up expenses of implementing EHR (Electronic Health Records). However, many of the healthcare institutions are yet to implement cloud computing due to the associated privacy and security issues. In this paper, we analyze the challenges and opportunities of implementing cloud computing in healthcare. We also analyze data of over 5000 US hospitals that use Telemedicine applications. This analysis helps to understand the importance of smart phones over the desktop systems in different departments of the healthcare institutions. The wide usage of smartphones and cloud computing allows ubiquitous and affordable access to the health data by authorized persons, including patients and doctors. Cloud computing will prove to be beneficial to a majority of the departments in healthcare. Through this analysis, we attempt to understand the different healthcare departments that may benefit significantly from the implementation of cloud computing.
Abstract: Wireless sensors, also known as wireless sensor nodes,
have been making a significant impact on human daily life. The
Radio Frequency Identification (RFID) and Wireless Sensor Network
(WSN) are two complementary technologies; hence, an integrated
implementation of these technologies expands the overall
functionality in obtaining long-range and real-time information on the
location and properties of objects and people. An approach for
integrating ZigBee and RFID networks is proposed in this paper, to
create an energy-efficient network improved by the benefits of
combining ZigBee and RFID architecture. Furthermore, the
compatibility and requirements of the ZigBee device and
communication links in the typical RFID system which is presented
with the real world experiment on the capabilities of the proposed
RFID system.
Abstract: While the feature sizes of recent Complementary Metal
Oxid Semiconductor (CMOS) devices decrease the influence of static
power prevails their energy consumption. Thus, power savings that
benefit from Dynamic Frequency and Voltage Scaling (DVFS) are
diminishing and temporal shutdown of cores or other microchip
components become more worthwhile. A consequence of powering off unused parts of a chip is that the
relative difference between idle and fully loaded power consumption
is increased. That means, future chips and whole server systems gain
more power saving potential through power-aware load balancing,
whereas in former times this power saving approach had only
limited effect, and thus, was not widely adopted. While powering
off complete servers was used to save energy, it will be superfluous
in many cases when cores can be powered down. An important
advantage that comes with that is a largely reduced time to respond
to increased computational demand. We include the above developments in a server power model
and quantify the advantage. Our conclusion is that strategies from
datacenters when to power off server systems might be used in the
future on core level, while load balancing mechanisms previously
used at core level might be used in the future at server level.
Abstract: Thoracotomy is a great surgery that has serious pulmonary complications, so purpose of this study was to determine the response of diaphragmatic excursion to inspiratory muscle trainer post thoracotomy. Thirty patients of both sexes (16 men and 14 women) with age ranged from 20 to 40 years old had done thoracotomy participated in this study. The practical work was done in cardiothoracic department, Kasr-El-Aini hospital at faculty of medicine for individuals 3 days Post operatively. Patients were assigned into two groups: group A (study group) included 15 patients (8 men and 7 women) who received inspiratory muscle training by using inspiratory muscle trainer for 20 minutes and routine chest physiotherapy (deep breathing, cough and early ambulation) twice daily, 3 days per week for one month. Group B (control group) included 15 patients (8 men and 7 women) who received the routine chest physiotherapy only (deep breathing, cough and early ambulation) twice daily, 3 days per week for one month. Ultrasonography was used to evaluate the changes in diaphragmatic excursion before and after training program. Statistical analysis revealed a significant increase in diaphragmatic excursion in the study group (59.52%) more than control group (18.66%) after using inspiratory muscle trainer post operatively in patients post thoracotomy. It was concluded that the inspiratory muscle training device increases diaphragmatic excursion in patients post thoracotomy through improving inspiratory muscle strength and improving mechanics of breathing and using of inspiratory muscle trainer as a method of physical therapy rehabilitation to reduce post-operative pulmonary complications post thoracotomy.
Abstract: This paper describes an ab-initio design, development and calibration results of an Optical Sensor Ground Reaction Force Measurement Platform (OSGRFP) for gait and geriatric studies. The developed system employs an array of FBG sensors to measure the respective ground reaction forces from all three axes (X, Y and Z), which are perpendicular to each other. The novelty of this work is two folded. One is in its uniqueness to resolve the tri axial resultant forces during the stance in to the respective pure axis loads and the other is the applicability of inherently advantageous FBG sensors which are most suitable for biomechanical instrumentation. To validate the response of the FBG sensors installed in OSGRFP and to measure the cross sensitivity of the force applied in other directions, load sensors with indicators are used. Further in this work, relevant mathematical formulations are presented for extracting respective ground reaction forces from wavelength shifts/strain of FBG sensors on the OSGRFP. The result of this device has implications in understanding the foot function, identifying issues in gait cycle and measuring discrepancies between left and right foot. The device also provides a method to quantify and compare relative postural stability of different subjects under test, which has implications in post-surgical rehabilitation, geriatrics and optimizing training protocols for sports personnel.
Abstract: The out-of-band impedance environment is considered
to be of paramount importance in engineering the in-band impedance
environment. Presenting the frequency independent and constant outof-
band impedances across the wide modulation bandwidth is
extremely important for reliable device characterization for future
wireless systems. This paper presents an out-of-band impedance
optimization scheme based on simultaneous engineering of
significant baseband components IF1 (twice the modulation
frequency) and IF2 (four times the modulation frequency) and higher
baseband components such as IF3 (six times the modulation
frequency) and IF4 (eight times the modulation frequency) to
engineer the in-band impedance environment. The investigations
were carried out on a 10W GaN HEMT device driven to deliver a
peak envelope power of approximately 40.5dBm under modulated
excitation. The presentation of frequency independent baseband
impedances to all the significant baseband components whilst
maintaining the optimum termination for fundamental tones as well
as reactive termination for 2nd harmonic under class-J mode of
operation has outlined separate optimum impedances for best
intermodulation (IM) linearity.
Abstract: The field of instrumentation electronics is undergoing
an explosive growth, due to its wide range of applications. The
proliferation of electrical devices in a close working proximity can
negatively influence each other’s performance. The degradation in
the performance is due to electromagnetic interference (EMI). This paper investigates the negative effects of electromagnetic
interference originating in the General Purpose Interface Bus (GPIB)
control-network of the AC-DC transfer measurement system.
Remedial measures of reducing measurement errors and failure of
range of industrial devices due to EMI have been explored. The ACDC
transfer measurement system was analysed for the commonmode
(CM) EMI effects. Further investigation of coupling path as
well as much accurate identification of noise propagation mechanism
has been outlined. To prevent the occurrence of common-mode
(ground loops) which was identified between the GPIB system
control circuit and the measurement circuit, a microcontroller-driven
GPIB switching isolator device was designed, prototyped,
programmed and validated. This mitigation technique has been
explored to reduce EMI effectively.
Abstract: In this paper, an Infinite Impulse Response (IIR) filter
has been designed and simulated on an Field Programmable Gate
Arrays (FPGA). The implementation is based on Multiply Add and
Accumulate (MAC) algorithm which uses multiply operations for
design implementation. Parallel Pipelined structure is used to
implement the proposed IIR Filter taking optimal advantage of the
look up table of target device. The designed filter has been
synthesized on Digital Signal Processor (DSP) slice based FPGA to
perform multiplier function of MAC unit. The DSP slices are useful
to enhance the speed performance. The proposed design is simulated
with Matlab, synthesized with Xilinx Synthesis Tool, and
implemented on FPGA devices. The Virtex 5 FPGA based design can
operate at an estimated frequency of 81.5 MHz as compared to 40.5
MHz in case of Spartan 3 ADSP based design. The Virtex 5 based
implementation also consumes less slices and slice flip flops of target
FPGA in comparison to Spartan 3 ADSP based implementation to
provide cost effective solution for signal processing applications.
Abstract: Weak damping of low frequency oscillations is a frequent phenomenon in electrical power systems. These frequencies can be damped by power system stabilizers. Unified power flow controller (UPFC), as one of the most important FACTS devices, can be applied to increase the damping of power system oscillations and the more effect of this controller on increasing the damping of oscillations depends on its proper placement in power systems. In this paper, a technique based on controllability is proposed to select proper location of UPFC and the best input control signal in order to enhance damping of power oscillations. The effectiveness of the proposed technique is demonstrated in IEEE 9 bus power system.
Abstract: Objective: Safety and efficacy of Ahmed glaucoma
valve implantation for the management of uveitis induced glaucoma
evaluated on the five dogs with uncontrollable glaucoma. Materials
and Methods: Ahmed Glaucoma Valve (AGV®; New World
Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, nonobstructive
self-regulating valve system. Preoperative ocular
evaluation included direct ophthalmoscopy and measurement of the
intraocular pressure (IOP). The implant was examined and primed
prior to implantation. The selected site of the valve implantation was
the superior quadrant between the superior and lateral rectus muscles.
A fornix-based incision was made through the conjunectiva and
Tenon’s capsule. A pocket is formed by blunt dissection of Tenon’s
capsule from the episclera. The body of the implant was inserted into
the pocket with the leading edge of the device around 8-10 mm from
the limbus. Results: No post-operative complications were detected
in the operated eyes except a persistent corneal edema occupied the
upper half of the cornea in one case. Hyphaema was very mild and
seen only in two cases which resolved quickly two days after surgery.
Endoscopical evaluation for the operated eyes revealed a normal
ocular fundus with clearly visible optic papilla, tapetum and retinal
blood vessels. No evidence of hemorrhage, infection, adhesions or
retinal abnormalities was detected. Conclusion: Ahmed glaucoma
valve is safe and effective implant for treatment of uveitic glaucoma
in dogs.
Abstract: There was a scenario present day that drying of fresh
fruits and vegetables by indirect solar drying by using mechanical
device; hence, an effort was made to develop a small scale solar
tunnel dryer (STD). Drying of spinach is carried out to analyze the
performance of the dryer and to study its drying characteristics. To
evaluate the performance of dryer the independent variables were
selected as air flow rate, loading density and shade net while collector
efficiency, drying efficiency, overall efficiency and specific energy
consumption were selected as responses during performing the
experiments. The spinach was dried from initial moisture content
88.21-94.04% (w.b.) to final moisture content 3.50-5.13% (w.b.). The
drying time considerably reduced as compared to open sun drying of
spinach as sun drying took 15 h for drying. The average collector
efficiency, drying efficiency and overall efficiency were in the range
28.73-61.15%, 11.63% to 22.13%, and 7.61-14.66%, respectively.
Abstract: Test automation allows performing difficult and time
consuming manual software testing tasks efficiently, quickly and
repeatedly. However, development and maintenance of automated
tests is expensive, so it needs a proper prioritization what to automate
first. This paper describes a simple yet efficient approach for such
prioritization of test cases based on the effort needed for both manual
execution and software test automation. The suggested approach is
very flexible because it allows working with a variety of assessment
methods, and adding or removing new candidates at any time. The
theoretical ideas presented in this article have been successfully
applied in real world situations in several software companies by the
authors and their colleagues including testing of real estate websites,
cryptographic and authentication solutions, OSGi-based middleware
framework that has been applied in various systems for smart homes,
connected cars, production plants, sensors, home appliances, car head
units and engine control units (ECU), vending machines, medical
devices, industry equipment and other devices that either contain or
are connected to an embedded service gateway.
Abstract: Cochlear Implantation (CI) which became a routine
procedure for the last decades is an electronic device that provides a
sense of sound for patients who are severely and profoundly deaf.
The optimal success of this implantation depends on the electrode
technology and deep insertion techniques. However, this manual
insertion procedure may cause mechanical trauma which can lead to
severe destruction of the delicate intracochlear structure.
Accordingly, future improvement of the cochlear electrode implant
insertion needs reduction of the excessive force application during
the cochlear implantation which causes tissue damage and trauma.
This study is examined tool-tissue interaction of large prototype scale
digit embedded with distributive tactile sensor based upon cochlear
electrode and large prototype scale cochlea phantom for simulating
the human cochlear which could lead to small scale digit
requirements. The digit, distributive tactile sensors embedded with
silicon-substrate was inserted into the cochlea phantom to measure
any digit/phantom interaction and position of the digit in order to
minimize tissue and trauma damage during the electrode cochlear
insertion. The digit have provided tactile information from the digitphantom
insertion interaction such as contact status, tip penetration,
obstacles, relative shape and location, contact orientation and
multiple contacts. The tests demonstrated that even devices of such a
relative simple design with low cost have potential to improve
cochlear implant surgery and other lumen mapping applications by
providing tactile sensory feedback information and thus controlling
the insertion through sensing and control of the tip of the implant
during the insertion. In that approach, the surgeon could minimize the
tissue damage and potential damage to the delicate structures within
the cochlear caused by current manual electrode insertion of the
cochlear implantation. This approach also can be applied to other
minimally invasive surgery applications as well as diagnosis and path
navigation procedures.