Abstract: The present work numerically analyzes the transient heat transfer in the absorber plates of a flat-plate solar collector based on the dual-phase-lag (DPL) heat conduction model. An efficient numerical scheme involving the hybrid application of the Laplace transform and control volume methods is used to solve the linear hyperbolic heat conduction equation. This work also examines the effect of different medium parameters on the behavior of heat transfer. Results show that, while the heat-flux phase lag induces thermal waves in the medium, the temperature-gradient phase lag smoothens the thermal waves by promoting non-Fourier diffusion-like conduction into the medium.
Abstract: Encapsulating the absorber of a flat plate solar thermal collector in vacuum by an enclosure that can be evacuated can result in a significant increase in collector performance and achievable operating temperatures. This is a result of the thermal insulation effectiveness of the vacuum layer surrounding the absorber, as less heat is lost during collector operation. This work describes experimental thermal insulation characterization tests of prototype vacuum flat plate solar thermal collectors that demonstrate the improvement in absorber heat loss coefficients. Furthermore, this work describes the selection and sizing of a getter, suitable for maintaining the vacuum inside the enclosure for the lifetime of the collector, which can be activated at low temperatures.
Abstract: Vacuum flat plate solar thermal collectors offer several advantages over other collectors namely the excellent optical and thermal characteristics they exhibit due to a combination of their wide surface area and high vacuum thermal insulation. These characteristics can offer a variety of applications for industrial process heat as well as for building integration as they are much thinner than conventional collectors making installation possible in limited spaces. However, many technical challenges which need to be addressed to enable wide scale adoption of the technology still remain. This paper will discuss the challenges, expectations and requirements for the flat-plate vacuum solar collector development. In addition, it will provide an overview of work undertaken in Ulster University, Loughborough University, and the University of Warwick on flat-plate vacuum solar thermal collectors. Finally, this paper will present a detailed experimental investigation on the development of a vacuum panel with a novel sealing method which will be used to accommodate a novel slim hydroformed solar absorber.
Abstract: A theoretical investigation on the effect of collector aspect ratio on the thermal performance of wavy finned absorber solar air heaters has been performed. For the constant collector area, the various performance parameters have been calculated for plane and wavy finned solar air heaters. It has been found that the performance of wavy finned solar air heater improved with the increase in the collector aspect ratio. The performance of wavy finned solar air heater has been found 30 percent higher than those of plane solar air heater. The obtained results for wavy fin solar air heaters are compared with the available experimental data of most common type solar air heaters.
Abstract: The power generated by eight point absorber type wave energy converters each having a different buoy are calculated in order to investigate the performances of buoys in this study. The calculations are carried out by modeling three different sea states observed in two different locations in the Black Sea. The floats analyzed in this study have two basic geometries and four different draft/radius (d/r) ratios. The buoys possess the shapes of a semi-ellipsoid and a semi-elliptic paraboloid. Additionally, the draft/radius ratios range from 0.25 to 1 by an increment of 0.25. The radiation forces acting on the buoys due to the oscillatory motions of these bodies are evaluated by employing a 3D panel method along with a distribution of 3D pulsating sources in frequency domain. On the other hand, the wave forces acting on the buoys which are taken as the sum of Froude-Krylov forces and diffraction forces are calculated by using linear wave theory. Furthermore, the wave energy converters are assumed to be taut-moored to the seabed so that the secondary body which houses a power take-off system oscillates with much smaller amplitudes compared to the buoy. As a result, it is assumed that there is not any significant contribution to the power generation from the motions of the housing body and the only contribution to power generation comes from the buoy. The power take-off systems of the wave energy converters are high pressure oil hydraulic systems which are identical in terms of their characteristic parameters. The results show that the power generated by wave energy converters which have semi-ellipsoid floats is higher than that of those which have semi elliptic paraboloid floats in both locations and in all sea states. It is also determined that the power generated by the wave energy converters follow an unsteady pattern such that they do not decrease or increase with changing draft/radius ratios of the floats. Although the highest power level is obtained with a semi-ellipsoid float which has a draft/radius ratio equal to 1, other floats of which the draft/radius ratio is 0.25 delivered higher power that the floats with a draft/radius ratio equal to 1 in some cases.
Abstract: This study investigated the differences in the objective parameters of sound depending on the changes in the lengths of the lateral surfaces of a space and on the replacement of the sound absorbers that are placed on these surfaces. To this end, three models of room were chosen. The widths and heights of these rooms were the same but the lengths of the rooms were changed. The smallest room was 8 m. wide and 10 m. long. The lengths of the other two rooms were 15 m. and 20 m. For each model, the differences in the objective parameters of sound were determined by keeping all the material in the space intact and by changing only the positions of the sound absorbers that were placed on the walls. The sound absorbers that were used on the walls were of two different sizes. The sound absorbers that were placed on the walls were 4 m and 8 m. long and story-height (3 m.). In all model room types, the sound absorbers were placed on the long walls in three different ways: at the end of the long walls where the long walls meet the front wall; at the end of the long walls where the long walls meet the back wall; and in the middle part of the long walls. Except for the specially placed sound absorbers, the ground, wall and ceiling surfaces were covered with three different materials. There were no constructional elements such as doors and windows on the walls. On the surfaces, the materials specified in the Odeon 10 material library were used as coating material. Linoleum was used as flooring material, painted plaster as wall coating material and gypsum boards as ceiling covering (2 layers with a total of 32 mm. thickness). These were preferred due to the fact that they are the commonly used materials for these purposes. This study investigated the differences in the objective parameters of sound depending on the changes in the lengths of the lateral surfaces of a space and on the replacement of the sound absorbers that are placed on these surfaces. To this end, three models of room were chosen. The widths and heights of these rooms were the same but the lengths of the rooms were changed. The smallest room was 8 m. wide and 10 m. long. The lengths of the other two rooms were 15 m. and 20 m. For each model, the differences in the objective parameters of sound were determined by keeping all the material in the space intact and by changing only the positions of the sound absorbers that were placed on the walls. The sound absorbers that were used on the walls were of two different sizes. The sound absorbers that were placed on the walls were 4 m and 8 m. long and story-height (3 m.). In all model room types, the sound absorbers were placed on the long walls in three different ways: at the end of the long walls where the long walls meet the front wall; at the end of the long walls where the long walls meet the back wall; and in the middle part of the long walls. Except for the specially placed sound absorbers, the ground, wall and ceiling surfaces were covered with three different materials. There were no constructional elements such as doors and windows on the walls. On the surfaces, the materials specified in the Odeon 10 material library were used as coating material. Linoleum was used as flooring material, painted plaster as wall coating material and gypsum boards as ceiling covering (2 layers with a total of 32 mm. thickness). These were preferred due to the fact that they are the commonly used materials for these purposes.
Abstract: Carbon dioxide is one of the major greenhouse gas
(GHG) contributors. It is an obligation of the industry to reduce the
amount of carbon dioxide emission to the acceptable limits.
Tremendous research and studies are reported in the past and still the
quest to find the suitable and economical solution of this problem
needed to be explored in order to develop the most plausible absorber
for carbon dioxide removal. Amino acids can be potential alternate
solvents for carbon dioxide capture from gaseous streams. This is due
to its ability to resist oxidative degradation, low volatility and its
ionic structure. In addition, the introduction of promoter-like
piperazine to amino acid helps to further enhance the solubility. In
this work, the effect of piperazine on thermo physical properties and
solubility of β-Alanine aqueous solutions were studied for various
concentrations. The measured physicochemical properties data was
correlated as a function of temperature using least-squares method
and the correlation parameters are reported together with it respective
standard deviations. The effect of activator piperazine on the CO2
loading performance of selected amino acid under high-pressure
conditions (1bar to 10bar) at temperature range of (30 to 60)oC was
also studied. Solubility of CO2 decreases with increasing temperature
and increases with increasing pressure. Quadratic representation of
solubility using Response Surface Methodology (RSM) shows that
the most important parameter to optimize solubility is system
pressure. The addition of promoter increases the solubility effect of
the solvent.
Abstract: In this paper, the exergy analysis of vapor absorption
refrigeration system using LiBr-H2O as working fluid is carried out
with the modified Gouy-Stodola approach rather than the classical
Gouy-Stodola equation and effect of varying input parameters is also
studied on the performance of the system. As the modified approach
uses the concept of effective temperature, the mathematical
expressions for effective temperature have been formulated and
calculated for each component of the system. Various constraints and
equations are used to develop program in EES to solve these
equations. The main aim of this analysis is to determine the
performance of the system and the components having major
irreversible loss. Results show that exergy destruction rate is
considerable in absorber and generator followed by evaporator and
condenser. There is an increase in exergy destruction in generator,
absorber and condenser and decrease in the evaporator by the
modified approach as compared to the conventional approach. The
value of exergy determined by the modified Gouy-Stodola equation
deviates maximum i.e. 26% in the generator as compared to the
exergy calculated by the classical Gouy-Stodola method.
Abstract: The main aim of the presented experiments is to
improve behaviour of sandwich structures under dynamic loading,
such as crash or explosion. This paper describes experimental
investigation on the response of new advanced materials to low and
high velocity load. Blast wave energy absorbers were designed using
two types of porous lightweight raw particle materials based on
expanded glass and ceramics with dimensions of 0.5-1 mm,
combined with polymeric binder. The effect of binder amount on the
static and dynamic properties of designed materials was observed.
Prism shaped specimens were prepared and loaded to obtain physicomechanical
parameters – bulk density, compressive and flexural
strength under quasistatic load, the dynamic response was determined
using Split Hopkinson Pressure bar apparatus. Numerical
investigation of the material behaviour in sandwich structure was
performed using implicit/explicit solver LS-Dyna. As the last step,
the developed material was used as the interlayer of blast resistant
litter bin, and it´s functionality was verified by real field blast tests.
Abstract: Solar energy is a good option among renewable
energy resources due to its easy availability and abundance. The
simplest and most efficient way to utilize solar energy is to convert it
into thermal energy and this can be done with the help of solar
collectors. The thermal performance of such collectors is poor due to
less heat transfer from the collector surface to air. In this work,
experimental investigations of single pass solar air heater having
triangular duct and provided with roughness element on the underside
of the absorber plate. V-shaped ribs are used for investigation having
three different values of relative roughness pitch (p/e) ranges from 4-
16 for a fixed value of angle of attack (α), relative roughness height
(e/Dh) and a relative gap distance (d/x) values are 60°, 0.044 and 0.60
respectively. Result shows that considerable augmentation in heat
transfer has been obtained by providing roughness.
Abstract: Solar air heater is a type of heat exchanger which
transforms solar radiation into heat energy. The thermal performance
of conventional solar air heater has been found to be poor because of
the low convective heat transfer coefficient from the absorber plate to
the air. It is attributed to the formation of a very thin boundary layer
at the absorber plate surface commonly known as viscous sub-layer.
Thermal efficiency of solar air heater can be improved by providing
the artificial roughness on absorber plate is the most efficient
technique. In this paper an attempt is made to provide artificial
roughness by incorporating inclined multiple V-ribs in the underside
of the absorber plate. 60˚V – ribs are arranged inclined to the
direction of air flow. Performance of collector estimated theoretically
and experimentally. Results of the investigation reveal that thermal
efficiency of collector with multiple V-ribs increased by 14%.
Abstract: A simple multi-wavelength passively Q-switched
Erbium-doped fiber laser (EDFL) is demonstrated using low cost
multi-walled carbon nanotubes (MWCNTs) based saturable absorber
(SA), which is prepared using polyvinyl alcohol (PVA) as a host
polymer. The multi-wavelength operation is achieved based on
nonlinear polarization rotation (NPR) effect by incorporating 50 m
long photonic crystal fiber (PCF) in the ring cavity. The EDFL
produces a stable multi-wavelength comb spectrum for more than 14
lines with a fixed spacing of 0.48 nm. The laser also demonstrates a
stable pulse train with the repetition rate increases from 14.9 kHz to
25.4 kHz as the pump power increases from the threshold power of
69.0 mW to the maximum pump power of 133.8 mW. The minimum
pulse width of 4.4 μs was obtained at the maximum pump power of
133.8 mW while the highest energy of 0.74 nJ was obtained at pump
power of 69.0 mW.
Abstract: There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of slit circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. The main parameters considered are: diameter-to-thickness (D/t) ratio and slit length-to-width ratio (l/w). Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. The susceptible location at which the possible crack is initiated is also identified for selected specimens using rupture index.
Abstract: In this study, the Mo-electrode thin films were deposited using two-stepped process and the high purity copper indium selenide-based powder (CuInSe2, CIS) was fabricated by using hydrothermal process by Nanowin Technology Co. Ltd. Because the CIS powder was aggregated into microscale particles, the CIS power was ground into nano-scale particles. 6 wt% CIS particles were mixed and dispersed into isopropyl alcohol (IPA). A new non-vacuum thin-film deposition process, spray coating method (SPM), was investigated to deposit the high-densified CIS absorber layers. 0.1 ml CIS solution was sprayed on the 20 mm×10 mm Mo/glass substrates and then the CuInSe2 thin films were annealed in a selenization furnace using N2 as atmosphere. The annealing temperature and time were set at 550oC and 5 min, and 0.0g~0.6g extra Se content was added in the furnace. The influences of extra Se content on the densification, crystallization, resistivity (ρ), hall mobility (μ), and carrier concentration of the CIS absorber layers were well investigated in this study.
Abstract: The idea of adding metallic energy dissipaters to a structure to absorb a large part of the seismic energy began four decades ago. There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of both stiffened and non stiffened circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. Diameter-to-thickness ratio is employed as main parameter to investigate the hysteresis performance of stiffened and unstiffened circular shear panel. Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. Hence, the hysteresis behavior is identified, specimens which deform without strength degradation so it will be used as passive energy dissipating device in civil engineering structures.
Abstract: Semi-active Fuzzy control of quarter car system having three degrees of freedom and assembled with magneto-rheological (MR) shock absorber is studied in present paper. First, experimental work was performed on an MR shock absorber under different excitation conditions to obtain force-displacement and force-velocity curves. Then, for the application of experimental data in semi-active quarter car system, a polynomial model was selected. Finally, Fuzzy logic controller was designed having the combination of Forward fuzzy controller and Inverse fuzzy controller for integration in secondary suspension system of concerned model. The proposed controlled quarter car model was compared with uncontrolled system using simulation work under bump type of road excitation. Results obtained by simulation work shows the effectiveness of fuzzy controlled suspension system in improving the ride comfort and safety of travelling passengers compared to uncontrolled suspension system.
Abstract: Owing to the lack of synchronization between the solar energy availability and the heat demands in a specific application, the energy storing sub-system is necessary to maintain the continuity of thermal process. The present work is dealing with an active solar heating storing system in which an air solar collector is connected to storing unit where this energy is distributed and provided to the heated space in a controlled manner. The solar collector is a box type absorber where the air flows between a number of vanes attached between the collector absorber and the bottom plate. This design can improve the efficiency due to increasing the heat transfer area exposed to the flowing air, as well as the heat conduction through the metal vanes from the top absorbing surface. The storing unit is a packed bed type where the air is coming from the air collector and circulated through the bed in order to add/remove the energy through the charging / discharging processes, respectively. The major advantage of the packed bed storage is its high degree of thermal stratification. Numerical solution of the packed bed energy storage is considered through dividing the bed into a number of equal segments for the bed particles and solved the energy equation for each segment depending on the neighbor ones. The studied design and performance parameters in the developed simulation model including, particle size, void fraction, etc. The final results showed that the collector efficiency was fluctuated between 55%-61% in winter season (January) under the climatic conditions of Misurata in Libya. Maximum temperature of 52ºC is attained at the top of the bed while the lower one is 25ºC at the end of the charging process of hot air into the bed. This distribution can satisfy the required load for the most house heating in Libya.
Abstract: Hybrid photovoltaic thermal (PVT) collectors allow simultaneous production of electrical energy thus heat energy. There are several configurations of hybrid collectors (to produce water or air). For hybrids water collectors, there are several configurations that differ by the nature of the absorber (serpentine, tubes...). In this paper, an absorber tank is studied. The circulation of the coolant is natural (we do not use the pump). We present the obtained results in our experimental study and we analyzed the data, and then we compare the results with the theory practices. The electrical performances of the hybrid collector are compared with those of conventional photovoltaic module mounted on the same structure and measured under the same conditions.
We conducted experiments with natural circulation of the coolant (Thermosyphon), for a flow rate of 0.025kg/m².
Abstract: This research investigated the properties of
Rhizophora charcoal for product design on 3 aspects: electrical
conductor, impurity absorption, and fresh fruit shelf life. After the
study, the properties of Rhizophora charcoal were applied to produce
local product model at Ban Yisarn, Ampawa District,
Samudsongkram Province which can add value to the Rhizophora
charcoal as one of the OTOP (One-Tambon-One product). The
results showed that the Rhizophora charcoal is not an electrical
conductor but good liquid impurity absorber and it can extend fresh
fruit shelf life.
Abstract: The development of vehicles having best ride comfort and safety of travelling passengers is of great interest for automotive manufacturers. The effect of transmitted vibrations from car body to passenger seat is required to be controlled for achieving the same. The application of magneto-rheological (MR) shock absorber in suspension system has been considered to achieve significant benefits in this regard. This paper introduces a secondary suspension controlled semi-active quarter car system using MR shock absorber for effective vibration control. Fuzzy logic control system is used for design of controller for actual damping force generation by MR shock absorber. Performance evaluations are done related to passenger seat acceleration and displacement in time and frequency domains, in order to see the effectiveness of the proposed semi-active suspension system. Simulation results show that the semi-active suspension system provides better results compared to passive suspension system in terms of passenger ride comfort improvement.