Abstract: Perth will run out of available sustainable natural
water resources by 2015 if nothing is done to slow usage rates,
according to a Western Australian study [1]. Alternative water
technology options need to be considered for the long-term
guaranteed supply of water for agricultural, commercial, domestic
and industrial purposes. Seawater is an alternative source of water for
human consumption, because seawater can be desalinated and
supplied in large quantities to a very high quality.
While seawater desalination is a promising option, the technology
requires a large amount of energy which is typically generated from
fossil fuels. The combustion of fossil fuels emits greenhouse gases
(GHG) and, is implicated in climate change. In addition to
environmental emissions from electricity generation for desalination,
greenhouse gases are emitted in the production of chemicals and
membranes for water treatment. Since Australia is a signatory to the
Kyoto Protocol, it is important to quantify greenhouse gas emissions
from desalinated water production.
A life cycle assessment (LCA) has been carried out to determine
the greenhouse gas emissions from the production of 1 gigalitre (GL)
of water from the new plant. In this LCA analysis, a new desalination
plant that will be installed in Bunbury, Western Australia, and known
as Southern Seawater Desalinization Plant (SSDP), was taken as a
case study. The system boundary of the LCA mainly consists of three
stages: seawater extraction, treatment and delivery. The analysis
found that the equivalent of 3,890 tonnes of CO2 could be emitted
from the production of 1 GL of desalinated water. This LCA analysis
has also identified that the reverse osmosis process would cause the
most significant greenhouse emissions as a result of the electricity
used if this is generated from fossil fuels
Abstract: Wastages such as grated coconut meat, spent tea and used sugarcane had contributed negative impacts to the environment. Vermicomposting method is fully utilized to manage the wastes towards a more sustainable approach. The worms that are used in the vermicomposting are Eisenia foetida and Eudrillus euginae. This research shows that the vermicompost of wastages has voltage of electrical energy and is able to light up the Light-Emitting Diode (LED) device. Based on the experiment, the use of replicated and double compartments of the component will produce double of voltage. Hence, for conclusion, this harmless and low cost technology of vermicompost can act as a dry cell in order to reduce the usage of hazardous chemicals that can contaminate the environment.
Abstract: A hybrid Photovoltaic/Thermal (PV/T) solar system integrates photovoltaic and solar thermal technologies into one single solar energy device, with dual generation of electricity and heat energy. The aim of the present study is to evaluate the potential for introduction of the PV/T technology into Northern China. For this purpose, outdoor experiments were conducted on a prototype of a PV/T water-heating system. The annual thermal and electrical performances were investigated under the climatic conditions of Beijing. An economic analysis of the system was then carried out, followed by a sensitivity study. The analysis revealed that the hybrid system is not economically attractive with the current market and energy prices. However, considering the continuous commitment of the Chinese government towards policy development in the renewable energy sector, and technological improvements like the increasing cost-effectiveness of PV cells, PV/Thermal technology may become economically viable in the near future.
Abstract: This paper presents the development of an electricity simulation model taking into account electrical network constraints, applied on the Belgian power system. The base of the model is optimizing an extensive Unit Commitment (UC) problem through the use of Mixed Integer Linear Programming (MILP). Electrical constraints are incorporated through the implementation of a DC load flow. The model encloses the Belgian power system in a 220 – 380 kV high voltage network (i.e., 93 power plants and 106 nodes). The model features the use of pumping storage facilities as well as the inclusion of spinning reserves in a single optimization process. Solution times of the model stay below reasonable values.
Abstract: In this paper variation of spot price and total profits of
the generating companies- through wholesale electricity trading are
discussed with and without Central Generating Stations (CGS) share
and seasonal variations are also considered. It demonstrates how
proper analysis of generators- efficiencies and capabilities, types of
generators owned, fuel costs, transmission losses and settling price
variation using the solutions of Optimal Power Flow (OPF), can
allow companies to maximize overall revenue. It illustrates how
solutions of OPF can be used to maximize companies- revenue under
different scenarios. And is also extended to computation of Available
Transfer Capability (ATC) is very important to the transmission
system security and market forecasting. From these results it is
observed that how crucial it is for companies to plan their daily
operations and is certainly useful in an online environment of
deregulated power system. In this paper above tasks are demonstrated
on 124 bus real-life Indian utility power system of Andhra Pradesh
State Grid and results have been presented and analyzed.
Abstract: In this paper, in order to investigate the effects of
photovoltaic system introduction to detached houses in Japan, two
kinds of works were done. Firstly, the hourly generation amount of a
4.2kW photovoltaic system were simulated in 46 cities to investigate
the potential of the system in different regions in Japan using a
simulation model of photovoltaic system. Secondly, based on the
simulated electricity generation amount, the energy saving, the
environmental and the economic effect of the photovoltaic system
were examined from hourly to annual timescales, based upon
calculations of typical electricity, heating, cooling and hot water
supply load profiles for Japanese dwellings. The above analysis was
carried out using a standard year-s hourly weather data for the
different city provided by the Expanded AMeDAS Weather Data
issued by AIJ (Architectural Institute of Japan).
Abstract: The use of wind energy for electricity generation is
growing rapidly across the world and in Portugal. However, the
geographical characteristics of the country along with the average
wind regime and with the environmental restrictions imposed to these
projects create limitations to the exploit of the onshore wind
resource. The best onshore wind spots are already committed and the
possibility of offshore wind farms in the Portuguese cost is now
being considered. This paper aims to make a contribution to the
evaluation of offshore wind power projects in Portugal. The technical
restrictions are addressed and the strategic, environmental and
financial interest of the project is analysed from the private company
and public points of view. The results suggest that additional support
schemes are required to ensure private investors interest for these
projects. Assuming an approach of direct substitution of energy
sources for electricity generation, the avoided CO2 equivalent
emissions for an offshore wind power project were quantified. Based
on the conclusions, future research is proposed to address the
environmental and social impacts of these projects.
Abstract: This paper presents a methodology to harvest the kinetic energy of the raindrops using piezoelectric devices. In the study 1m×1m PVDF (Polyvinylidene fluoride) piezoelectric membrane, which is fixed by the four edges, is considered for the numerical simulation on deformation of the membrane due to the impact of the raindrops. Then according to the drop size of the rain, the simulation is performed classifying the rainfall types into three categories as light stratiform rain, moderate stratiform rain and heavy thundershower. The impact force of the raindrop is dependent on the terminal velocity of the raindrop, which is a function of raindrop diameter. The results were then analyzed to calculate the harvestable energy from the deformation of the piezoelectric membrane.
Abstract: The Long-range Energy and Alternatives Planning (LEAP) energy planning system has been developed for South Africa, for the 2005 base year and a limited number of plausible future scenarios that may have significant implications (negative or positive) in terms of environmental impacts. The system quantifies the national energy demand for the domestic, commercial, transport, industry and agriculture sectors, the supply of electricity and liquid fuels, and the resulting emissions. The South African National Energy Research Institute (SANERI) identified the need to develop an environmental assessment tool, based on the LEAP energy planning system, to provide decision-makers and stakeholders with the necessary understanding of the environmental impacts associated with different energy scenarios. A comprehensive analysis of indicators that are used internationally and in South Africa was done and the available data was accessed to select a reasonable number of indicators that could be utilized in energy planning. A consultative process was followed to determine the needs of different stakeholders on the required indicators and also the most suitable form of reporting. This paper demonstrates the application of Energy Environmental Sustainability Indicators (EESIs) as part of the developed tool, which assists with the identification of the environmental consequences of energy generation and use scenarios and thereby promotes sustainability, since environmental considerations can then be integrated into the preparation and adoption of policies, plans, programs and projects. Recommendations are made to refine the tool further for South Africa.
Abstract: Petrol Fuel Station (PFS) has potential hazards to the
people, asset, environment and reputation of an operating company.
Fire hazards, static electricity air pollution evoked by aliphatic and
aromatic organic compounds are major causes of accident/incident
occurrence at fuel station. Activities such as carelessness,
maintenance, housekeeping, slips trips and falls, transportation
hazard, major and minor injuries, robbery and snake bites has a
potential to create unsafe conditions. The level of risk of these
hazards varies according to location and country. The emphasis on
safety considerations by the government is variable all around the
world. Developed countries safety records are much better as
compared to developing countries safety statistics. There is no
significant approach available to highlight the unsafe acts and unsafe
conditions during operation and maintenance of fuel station. Fuel
station is the most commonly available facilities that contain
flammable and hazardous materials. Due to continuous operation of
fuel station they pose various hazards to people, environment and
assets of an organization. To control these hazards, there is a need for
specific approach. PFS operation is unique as compared to other
businesses. For smooth operations it demands an involvement of
operating company, contractor and operator group. This study will
focus to address hazard contributing factors that have a potential to
make PFS operation risky. One year data collected, 902 activities
analyzed, comparisons were made to highlight significant
contributing factors. The study will provide help and assistance to
PFS outlet marketing companies to make their fuel station operation
safer. It will help health safety and environment (HSE) professionals
to arrest the gap available related to safety matters at PFS.
Abstract: The deficit of power for electricity demand reaches
almost 30% for consumers in the last few years. This reflects with
continually increasing the price of electricity, and today the price for
small industry is almost 110Euro/MWh. The high price is additional
problem for the owners in the economy crisis which is reflected with
higher price of the goods.
The paper gives analyses of the energy needs for real agro
complex in Macedonia, private vinery with capacity of over 2 million
liters in a year and with self grapes and fruits fields. The existing
power supply is from grid with 10/04 kV transformer. The
geographical and meteorological condition of the vinery location
gives opportunity for including renewable as a power supply option
for the vinery complex.
After observation of the monthly energy needs for the vinery, the
base scenario is the existing power supply from the distribution grid.
The electricity bill in small industry has three factors: electricity in
high and low tariffs in kWh and the power engaged for the
technological process of production in kW. These three factors make
the total electricity bill and it is over 110 Euro/MWh which is the
price near competitive for renewable option. On the other side
investments in renewable (especially photovoltaic (PV)) has tendency
of decreasing with price of near 1,5 Euro/W. This means that
renewable with PV can be real option for power supply for small
industry capacities (under 500kW installed power).
Therefore, the other scenarios give the option with PV and the last
one includes wind option. The paper presents some scenarios for
power supply of the vinery as the followings:
• Base scenario of existing conventional power supply from the
grid
• Scenario with implementation of renewable of Photovoltaic
• Scenario with implementation of renewable of Photovoltaic and
Wind power
The total power installed in a vinery is near 570 kW, but the
maximum needs are around 250kW. At the end of the full paper some
of the results from scenarios will be presented. The paper also
includes the environmental impacts of the renewable scenarios, as
well as financial needs for investments and revenues from renewable.
Abstract: This paper describes the design and development of pico-hydro generation system using consuming water distributed to houses. Water flow in the domestic pipes has kinetic energy that potential to generate electricity for energy storage purposes in addition to the routine activities such as laundry, cook and bathe. The inherent water pressure and flow inside the pipe from utility-s main tank that used for those usual activities is also used to rotate small scale hydro turbine to drive a generator for electrical power generation. Hence, this project is conducted to develop a small scale hydro generation system using consuming water distributed to houses as an alternative electrical energy source for residential use.
Abstract: This study deals with the phenomena of reflection and transmission (refraction) of qSV-waves, for an incident of quasi transverse vertically waves, at a plane interface of two semi-infinite piezoelectric elastic media under the influence of the initial stresses. The relations governing the reflection and transmission coefficients of these reflected waves for various suitable boundary conditions are derived. We have shown analytically that reflection and transmission coefficients of (qP) and (qSV) waves depend upon the angle of incidence, the parameters of electric potential, the material constants of the medium as will as the initial stresses presented in the media. The numerical calculations of the reflection and transmission amplitude ratios for different values of initial stresses have been carried out by computer for different materials as examples and the results are given in the form of graphs. Finally, some of particular cases are considered.
Abstract: In designing river intakes and diversion structures, it is paramount that the sediments entering the intake are minimized or, if possible, completely separated. Due to high water velocity, sediments can significantly damage hydraulic structures especially when mechanical equipment like pumps and turbines are used. This subsequently results in wasting water, electricity and further costs. Therefore, it is prudent to investigate and analyze the performance of lateral intakes affected by sediment control structures. Laboratory experiments, despite their vast potential and benefits, can face certain limitations and challenges. Some of these include: limitations in equipment and facilities, space constraints, equipment errors including lack of adequate precision or mal-operation, and finally, human error. Research has shown that in order to achieve the ultimate goal of intake structure design – which is to design longlasting and proficient structures – the best combination of sediment control structures (such as sill and submerged vanes) along with parameters that increase their performance (such as diversion angle and location) should be determined. Cost, difficulty of execution and environmental impacts should also be included in evaluating the optimal design. This solution can then be applied to similar problems in the future. Subsequently, the model used to arrive at the optimal design requires high level of accuracy and precision in order to avoid improper design and execution of projects. Process of creating and executing the design should be as comprehensive and applicable as possible. Therefore, it is important that influential parameters and vital criteria is fully understood and applied at all stages of choosing the optimal design. In this article, influential parameters on optimal performance of the intake, advantages and disadvantages, and efficiency of a given design are studied. Then, a multi-criterion decision matrix is utilized to choose the optimal model that can be used to determine the proper parameters in constructing the intake.
Abstract: Response to the public health-related emergencies is analysed here for a rural university in South Africa. The structure of the designated emergency plan covers all the phases of the disaster management cycle. The plan contains elements of the vulnerability model and the technocratic model of emergency management. The response structures are vertically and horizontally integrated, while the planning contains elements of scenario-based and functional planning. The available number of medical professionals at the Rhodes University, along with the medical insurance rates, makes the staff and students potentially more medically vulnerable than the South African population. The main improvements of the emergency management are required in the tornado response and the information dissemination during health emergencies. The latter should involve the increased use of social media and e-mails, following the Taylor model of communication. Infrastructure must be improved in the telecommunication sector in the face of unpredictable electricity outages.
Abstract: Lean, which was initially developed by Toyota, is
widely implemented in other companies to improve competitiveness.
This research is an attempt to identify the adoption of lean in the
production system of Malaysian car manufacturer, Proton using case
study approach. To gain the in-depth information regarding lean
implementation, an activity on the assembly line called Set Parts
Supply (SPS) was studied. The result indicates that by using lean
principles, tools and techniques in the implementation of SPS enabled
to achieve the goals on safety, quality, cost, delivery and morale. The
implementation increased the size of the workspace, improved the
quality of assembly and the delivery of parts supply, reduced the
manpower, achieved cost savings on electricity and also increased the
motivation of manpower in respect of attendance at work. A
framework of SPS implementation is suggested as a contribution for
lean practices in production system.
Abstract: Over half of the total electricity consumption is used in buildings. Air-conditioning and electric lighting are the two main resources of electricity consumption in high rise buildings. One way to reduce electricity consumption would be to limit heat gain into buildings, therefore reduce the demand for air-conditioning during hot summer months especially in hot regions. On the other hand natural daylight can be used to reduce the use of electricity for artificial lighting. In this paper effective factors on minimizing heat gain and achieving required day light were reviewed .As daylight always accompanied by solar heat gain. Also interactions between heat gain and daylight were discussed through previous studies and equations which are related to heat gain and day lighting especially in high rise buildings. As a result importance of building-s form and its component on energy consumption in buildings were clarified.
Abstract: Off-grid Photovoltaic (PV) systems are empowering
technology in underdeveloped countries like Ethiopia where many
people live far away from the modern world. Where there is
relatively low energy consumption, providing energy from grid
systems is not commercially cost-effective. As a result, significant
people groups worldwide stay without access to electricity. One
remote village in northern Ethiopia was selected by the United
Nations for a pilot project to improve its living conditions. As part of
this comprehensive project, an intelligent charge controller circuit for
Off-grid PV systems was designed for the clinic in that village. In
this paper, design aspects of an intelligent charge controller unit and
its load driver circuits are discussed for an efficient utilization of PVbased
supply systems.
Abstract: Rapid economic development and population growth
in Malaysia had accelerated the generation of solid waste. This issue
gives pressure for effective management of municipal solid waste
(MSW) to take place in Malaysia due to the increased cost of landfill.
This paper discusses optimal planning of waste-to-energy (WTE)
using a combinatorial simulation and optimization model through
mixed integer linear programming (MILP) approach. The proposed
multi-period model is tested in Iskandar Malaysia (IM) as case study
for a period of 12 years (2011 -2025) to illustrate the economic
potential and tradeoffs involved in this study. In this paper, 3
scenarios have been used to demonstrate the applicability of the
model: (1) Incineration scenario (2) Landfill scenario (3) Optimal
scenario. The model revealed that the minimum cost of electricity
generation from 9,995,855 tonnes of MSW is estimated as USD
387million with a total electricity generation of 50MW /yr in the
optimal scenario.
Abstract: The main aim of this work is to establish the
capabilities of new green buildings to ascertain off-grid electricity
generation based on the integration of wind turbines in the
conceptual model of a rotating tower [2] in Dubai. An in depth
performance analysis of the WinWind 3.0MW [3] wind turbine is
performed. Data based on the Dubai Meteorological Services is
collected and analyzed in conjunction with the performance analysis
of this wind turbine. The mathematical model is compared with
Computational Fluid Dynamics (CFD) results based on a conceptual
rotating tower design model. The comparison results are further
validated and verified for accuracy by conducting experiments on a
scaled prototype of the tower design. The study concluded that
integrating wind turbines inside a rotating tower can generate enough
electricity to meet the required power consumption of the building,
which equates to a wind farm containing 9 horizontal axis wind
turbines located at an approximate area of 3,237,485 m2 [14].