Abstract: In this paper, a novel method using Bees Algorithm is proposed to determine the optimal allocation of FACTS devices for maximizing the Available Transfer Capability (ATC) of power transactions between source and sink areas in the deregulated power system. The algorithm simultaneously searches the FACTS location, FACTS parameters and FACTS types. Two types of FACTS are simulated in this study namely Thyristor Controlled Series Compensator (TCSC) and Static Var Compensator (SVC). A Repeated Power Flow with FACTS devices including ATC is used to evaluate the feasible ATC value within real and reactive power generation limits, line thermal limits, voltage limits and FACTS operation limits. An IEEE30 bus system is used to demonstrate the effectiveness of the algorithm as an optimization tool to enhance ATC. A Genetic Algorithm technique is used for validation purposes. The results clearly indicate that the introduction of FACTS devices in a right combination of location and parameters could enhance ATC and Bees Algorithm can be efficiently used for this kind of nonlinear integer optimization.
Abstract: Routing in MANET is extremely challenging because
of MANETs dynamic features, its limited bandwidth, frequent
topology changes caused by node mobility and power energy
consumption. In order to efficiently transmit data to destinations, the
applicable routing algorithms must be implemented in mobile ad-hoc
networks. Thus we can increase the efficiency of the routing by
satisfying the Quality of Service (QoS) parameters by developing
routing algorithms for MANETs. The algorithms that are inspired by
the principles of natural biological evolution and distributed
collective behavior of social colonies have shown excellence in
dealing with complex optimization problems and are becoming more
popular. This paper presents a survey on few meta-heuristic
algorithms and naturally-inspired algorithms.
Abstract: This paper presents the comparison study of current control techniques for shunt active power filter. The hysteresis current control, the delta modulation control and the carrier-based PWM control are considered in the paper. The synchronous detection method is used to calculate the reference currents for shunt active power filter. The simulation results show that the carrier-based PWM control technique provides the minimum %THD value of the source currents compared with other comparable techniques after compensation. However, the %THD values of all three techniques can follow the IEEE std.519-1992.
Abstract: The paper presents new results of a recent industry
supported research and development study in which an efficient
framework for evaluating practical and meaningful power system
reliability and quality indices was applied. The system-wide
integrated performance indices are capable of addressing and
revealing areas of deficiencies and bottlenecks as well as
redundancies in the composite generation-transmission-demand
structure of large-scale power grids. The technique utilizes a linear
programming formulation, which simulates practical operating
actions and offers a general and comprehensive framework to assess
the harmony and compatibility of generation, transmission and
demand in a power system. Practical applications to a reduced
system model as well as a portion of the Saudi power grid are also
presented in the paper for demonstration purposes.
Abstract: This paper presents a new method which applies an
artificial bee colony algorithm (ABC) for capacitor placement in
distribution systems with an objective of improving the voltage profile
and reduction of power loss. The ABC algorithm is a new population
based meta heuristic approach inspired by intelligent foraging behavior
of honeybee swarm. The advantage of ABC algorithm is that
it does not require external parameters such as cross over rate and
mutation rate as in case of genetic algorithm and differential evolution
and it is hard to determine these parameters in prior. The other
advantage is that the global search ability in the algorithm is implemented
by introducing neighborhood source production mechanism
which is a similar to mutation process. To demonstrate the validity
of the proposed algorithm, computer simulations are carried out on
69-bus system and compared the results with the other approach
available in the literature. The proposed method has outperformed the
other methods in terms of the quality of solution and computational
efficiency.
Abstract: The equivalence class subset algorithm is a powerful
tool for solving a wide variety of constraint satisfaction problems and
is based on the use of a decision function which has a very high but
not perfect accuracy. Perfect accuracy is not required in the decision
function as even a suboptimal solution contains valuable information
that can be used to help find an optimal solution. In the hardest
problems, the decision function can break down leading to a
suboptimal solution where there are more equivalence classes than
are necessary and which can be viewed as a mixture of good decision
and bad decisions. By choosing a subset of the decisions made in
reaching a suboptimal solution an iterative technique can lead to an
optimal solution, using series of steadily improved suboptimal
solutions. The goal is to reach an optimal solution as quickly as
possible. Various techniques for choosing the decision subset are
evaluated.
Abstract: Economic Load Dispatch (ELD) is a method of determining
the most efficient, low-cost and reliable operation of a power
system by dispatching available electricity generation resources to
supply load on the system. The primary objective of economic
dispatch is to minimize total cost of generation while honoring
operational constraints of available generation resources. In this paper
an intelligent water drop (IWD) algorithm has been proposed to
solve ELD problem with an objective of minimizing the total cost of
generation. Intelligent water drop algorithm is a swarm-based natureinspired
optimization algorithm, which has been inspired from natural
rivers. A natural river often finds good paths among lots of possible
paths in its ways from source to destination and finally find almost
optimal path to their destination. These ideas are embedded into
the proposed algorithm for solving economic load dispatch problem.
The main advantage of the proposed technique is easy is implement
and capable of finding feasible near global optimal solution with
less computational effort. In order to illustrate the effectiveness of
the proposed method, it has been tested on 6-unit and 20-unit test
systems with incremental fuel cost functions taking into account the
valve point-point loading effects. Numerical results shows that the
proposed method has good convergence property and better in quality
of solution than other algorithms reported in recent literature.
Abstract: Reliability Centered Maintenance(RCM) is one of
most widely used methods in the modern power system to schedule a
maintenance cycle and determine the priority of inspection. In order
to apply the RCM method to the Smart Grid, a precedence study for
the new structure of rearranged system should be performed due to
introduction of additional installation such as renewable and
sustainable energy resources, energy storage devices and advanced
metering infrastructure. This paper proposes a new method to
evaluate the priority of maintenance and inspection of the power
system facilities in the Smart Grid using the Risk Priority Number. In
order to calculate that risk index, it is required that the reliability
block diagram should be analyzed for the Smart Grid system. Finally,
the feasible technical method is discussed to estimate the risk
potential as part of the RCM procedure.
Abstract: Although White LED lighting systems powered by solar cells have presented for many years, they are not widely used in today application because of their cost and low energy conversion efficiency. The proposed system use the dc power generated by fixed solar cells module to energize White LED light sources that are operated by directly connected White LED with current limitation resistors, resulting in much more power consumption. This paper presents the use of white LED as a general lighting application powered by tracking solar cells module and using pulse to apply the electrical power to the White LED. These systems resulted in high efficiency power conversion, low power consumption, and long light of the white LED.
Abstract: The world of wireless telecommunications is rapidly evolving. Technologies under research and development promise to deliver more services to more users in less time. This paper presents the emerging technologies helping wireless systems grow from where we are today into our visions of the future. This paper will cover the applications and characteristics of emerging wireless technologies: Wireless Local Area Networks (WiFi-802.11n), Wireless Personal Area Networks (ZigBee) and Wireless Metropolitan Area Networks (WiMAX). The purpose of this paper is to explain the impending 802.11n standard and how it will enable WLANs to support emerging media-rich applications. The paper will also detail how 802.11n compares with existing WLAN standards and offer strategies for users considering higher-bandwidth alternatives. The emerging IEEE 802.15.4 (ZigBee) standard aims to provide low data rate wireless communications with high-precision ranging and localization, by employing UWB technologies for a low-power and low cost solution. WiMAX (Worldwide Interoperability for Microwave Access) is a standard for wireless data transmission covering a range similar to cellular phone towers. With high performance in both distance and throughput, WiMAX technology could be a boon to current Internet providers seeking to become the leader of next generation wireless Internet access. This paper also explores how these emerging technologies differ from one another.
Abstract: This paper presents a systematic approach for designing Unified Power Flow Controller (UPFC) based supplementary damping controllers for damping low frequency oscillations in a single-machine infinite-bus power system. Detailed investigations have been carried out considering the four alternatives UPFC based damping controller namely modulating index of series inverter (mB), modulating index of shunt inverter (mE), phase angle of series inverter (δB ) and phase angle of the shunt inverter (δE ). The design problem of the proposed controllers is formulated as an optimization problem and Real- Coded Genetic Algorithm (RCGA) is employed to optimize damping controller parameters. Simulation results are presented and compared with a conventional method of tuning the damping controller parameters to show the effectiveness and robustness of the proposed design approach.
Abstract: In this paper an algorithm for fast wavelength calibration of Optical Spectrum Analyzers (OSAs) using low power reference gas spectra is proposed. In existing OSAs a reference spectrum with low noise for precise detection of the reference extreme values is needed. To generate this spectrum costly hardware with high optical power is necessary. With this new wavelength calibration algorithm it is possible to use a noisy reference spectrum and therefore hardware costs can be cut. With this algorithm the reference spectrum is filtered and the key information is extracted by segmenting and finding the local minima and maxima. Afterwards slope and offset of a linear correction function for best matching the measured and theoretical spectra are found by correlating the measured with the stored minima. With this algorithm a reliable wavelength referencing of an OSA can be implemented on a microcontroller with a calculation time of less than one second.
Abstract: This paper presents an approach for the design of
fuzzy logic power system stabilizers using genetic algorithms. In the
proposed fuzzy expert system, speed deviation and its derivative
have been selected as fuzzy inputs. In this approach the parameters of
the fuzzy logic controllers have been tuned using genetic algorithm.
Incorporation of GA in the design of fuzzy logic power system
stabilizer will add an intelligent dimension to the stabilizer and
significantly reduces computational time in the design process. It is
shown in this paper that the system dynamic performance can be
improved significantly by incorporating a genetic-based searching
mechanism. To demonstrate the robustness of the genetic based
fuzzy logic power system stabilizer (GFLPSS), simulation studies on
multimachine system subjected to small perturbation and three-phase
fault have been carried out. Simulation results show the superiority
and robustness of GA based power system stabilizer as compare to
conventionally tuned controller to enhance system dynamic
performance over a wide range of operating conditions.
Abstract: This paper presents a procedure for modeling and tuning the parameters of Thyristor Controlled Series Compensation (TCSC) controller in a multi-machine power system to improve transient stability. First a simple transfer function model of TCSC controller for stability improvement is developed and the parameters of the proposed controller are optimally tuned. Genetic algorithm (GA) is employed for the optimization of the parameter-constrained nonlinear optimization problem implemented in a simulation environment. By minimizing an objective function in which the oscillatory rotor angle deviations of the generators are involved, transient stability performance of the system is improved. The proposed TCSC controller is tested on a multi-machine system and the simulation results are presented. The nonlinear simulation results validate the effectiveness of proposed approach for transient stability improvement in a multimachine power system installed with a TCSC. The simulation results also show that the proposed TCSC controller is also effective in damping low frequency oscillations.
Abstract: The common practice of operating S-rotor is in an
open environment; however there are times when the rotor is
installed in a bounded environment and there might be changes in the
performance of the rotor. This paper presents the changes in the
performance of S-rotor when operated in bounded flows. The
investigation was conducted experimentally to compare the
performance of the rotors in bounded environment against open
environment. Three different rotors models were designed, fabricated
and subjected to experimental measurements. All of the three models
were having 600 mm height and 300 mm Diameter. They were tested
in three different flow environments; namely: partially bounded
environment, fully bounded environment and open environment.
Rotors were found to have better starting up capabilities when
operated in bounded environment. Apart from that, all rotors manage
to achieve higher Power and Torque Coefficients at a higher Tip
Speed Ratio as compared to the open environment.
Abstract: Number Link is a Japanese logic puzzle where pairs of same numbers are connected using lines. Number Link can be regarded as a dynamic multiple travelers, multiple entries and exits maze, where the walls and passages are dynamically changing as the travelers move. In this paper, we apply the Tremaux’s algorithm to solve Number Link puzzles of size 8x8, 10x10 and 15x20. The algorithm works well and produces a solution for puzzles of size 8x8 and 10x10. However, solving a puzzle of size 15x20 requires high computer processing power and is time consuming.
Abstract: This paper presents a method for the detection of OD in the retina which takes advantage of the powerful preprocessing techniques such as the contrast enhancement, Gabor wavelet transform for vessel segmentation, mathematical morphology and Earth Mover-s distance (EMD) as the matching process. The OD detection algorithm is based on matching the expected directional pattern of the retinal blood vessels. Vessel segmentation method produces segmentations by classifying each image pixel as vessel or nonvessel, based on the pixel-s feature vector. Feature vectors are composed of the pixel-s intensity and 2D Gabor wavelet transform responses taken at multiple scales. A simple matched filter is proposed to roughly match the direction of the vessels at the OD vicinity using the EMD. The minimum distance provides an estimate of the OD center coordinates. The method-s performance is evaluated on publicly available DRIVE and STARE databases. On the DRIVE database the OD center was detected correctly in all of the 40 images (100%) and on the STARE database the OD was detected correctly in 76 out of the 81 images, even in rather difficult pathological situations.
Abstract: Selected Mapping (SLM) is a PAPR reduction technique, which converts the OFDM signal into several independent signals by multiplication with the phase sequence set and transmits one of the signals with lowest PAPR. But it requires the index of the selected signal i.e. side information (SI) to be transmitted with each OFDM symbol. The PAPR reduction capability of the SLM scheme depends on the selection of phase sequence set. In this paper, we have proposed a new phase sequence set generation scheme based on M-ary chaotic sequence and a mapping scheme to map quaternary data to concentric circle constellation (CCC) is used. It is shown that this method does not require SI and provides better SER performance with good PAPR reduction capability as compared to existing SLMOFDM methods.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: This study examines the design and construction of AC Electronics load surge protection in order to carry electric surge load arisen from faults in low voltage electricity system (single phase/220V) by using the principle of electronics load clamping voltage during induction period so that electric voltage could go through to safe load and continue to work. The qualification of the designed device could prevent both transient over voltage and voltage swell. Both will work in cooperation, resulting in the ability to improve and modify the quality of electrical power in Thailand electricity distribution system more effective than the past and help increase the lifetime of electric appliances, electric devices, and electricity protection equipments.