Abstract: This study focuses on emission of black carbon (BC)
from field open burning of corn residues. Real-time BC
concentration was measured by Micro Aethalometer from field
burning and simulated open burning in a chamber (SOC)
experiments. The average concentration of BC was 1.18±0.47 mg/m3
in the field and 0.89±0.63 mg/m3 in the SOC. The deduced emission
factor from field experiments was 0.50±0.20 gBC/kgdm, and 0.56±0.33
gBC/kgdm from SOC experiment, which are in good agreement with
other studies. In 2007, the total burned area of corn crop was 8,000
ha, resulting in an emission load of BC 20 ton corresponding to 44.5
million kg CO2 equivalent. Therefore, the control of open burning in
corn field represents a significant global warming reduction option.
Abstract: In this paper, a two-dimensional (2D) numerical
model for the tidal currents simulation in Persian Gulf is presented.
The model is based on the depth averaged equations of shallow water
which consider hydrostatic pressure distribution. The continuity
equation and two momentum equations including the effects of bed
friction, the Coriolis effects and wind stress have been solved. To
integrate the 2D equations, the Alternative Direction Implicit (ADI)
technique has been used. The base of equations discritization was
finite volume method applied on rectangular mesh. To evaluate the
model validation, a dam break case study including analytical
solution is selected and the comparison is done. After that, the
capability of the model in simulation of tidal current in a real field is
represented by modeling the current behavior in Persian Gulf. The
tidal fluctuations in Hormuz Strait have caused the tidal currents in
the area of study. Therefore, the water surface oscillations data at
Hengam Island on Hormoz Strait are used as the model input data.
The check point of the model is measured water surface elevations at
Assaluye port. The comparison between the results and the
acceptable agreement of them showed the model ability for modeling
marine hydrodynamic.
Abstract: The value of emission factor was calculated in the
older type of Diesel engine operating on an engine testing bench and
then compared with the parameters monitored under similar
conditions when the EnviroxTM additive was applied. It has been
found out that the additive based on CeO2 nanoparticles reduces
emission of NOx. The dependencies of NOx emissions on reduced
torque, engine power and revolutions have been observed as well.
Abstract: Desert regions around the Nile valley in Upper Egypt
contain great extent of swelling soil. Many different comment
procedures of treatment of the swelling soils for construction such as
pre-swelling, load balance OR soil replacement. One of the measure
factors which affect the level of the aggressiveness of the swelling
soil is the direction of the infiltration water directions within the
swelling soils. In this paper a physical model was installed to
measure the effect of water on the swelling soil with replacement
using fatty acid distillation residuals (FADR) mixed with sand as
thick sand-FADR mixture to prevent the water pathway arrive to the
swelling soil. Testing program have been conducted on different
artificial samples with different sand to FADR contents ratios (4%,
6%, and 9%) to get the optimum value fulfilling the impermeable
replacement. The tests show that a FADR content of 9% is sufficient
to produce impermeable replacement.
Abstract: We measured the major and trace element contents
and Rb-Sr isotopic compositions of 12 tektites from the Maoming
area, Guandong province (south China). All the samples studied are
splash-form tektites which show pitted or grooved surfaces with
schlieren structures on some surfaces. The trace element ratios Ba/Rb
(avg. 4.33), Th/Sm (avg. 2.31), Sm/Sc (avg. 0.44), Th/Sc (avg. 1.01) ,
La/Sc (avg. 2.86), Th/U (avg. 7.47), Zr/Hf (avg. 46.01) and the rare
earth elements (REE) contents of tektites of this study are similar to the
average upper continental crust. From the chemical composition, it is
suggested that tektites in this study are derived from similar parental
terrestrial sedimentary deposit which may be related to post-Archean
upper crustal rocks. The tektites from the Maoming area have high
positive εSr(0) values-ranging from 176.9~190.5 which indicate that
the parental material for these tektites have similar Sr isotopic
compositions to old terrestrial sedimentary rocks and they were not
dominantly derived from recent young sediments (such as soil or
loess). The Sr isotopic data obtained by the present study support the
conclusion proposed by Blum et al. (1992)[1] that the depositional age
of sedimentary target materials is close to 170Ma (Jurassic). Mixing
calculations based on the model proposed by Ho and Chen (1996)[2]
for various amounts and combinations of target rocks indicate that the
best fit for tektites from the Maoming area is a mixture of 40% shale,
30% greywacke, 30% quartzite.
Abstract: Protecting is the sources of drinking water is the first
barrier of contamination of drinking water. The Feitsui Reservoir
watershed of Taiwan supplies domestic water for around 5 million
people in the Taipei metropolitan area. Understanding the spatial
patterns of water quality trends in this watershed is an important
agenda for management authorities. This study examined 7 sites in the
watershed for water quality parameters regulated in the standard for
drinking water source. The non-parametric seasonal Mann-Kendall-s
test was used to determine significant trends for each parameter.
Significant trends of increasing pH occurred at the sampling station in
the uppermost stream watershed, and in total phosphorus at 4 sampling
stations in the middle and downstream watershed. Additionally, the
multi-scale land cover assessment and average land slope were used to
explore the influence on the water quality in the watershed. Regression
models for predicting water quality were also developed.
Abstract: The performance of modified Fenton (MF) treatment
to promote PAH oxidation in artificially contaminated soil was
investigated in packed soil column with a hydrogen peroxide (H2O2)
delivery system simulating in situ injection. Soil samples were spiked
with phenanthrene (low molecular weight PAH) and fluoranthene
(high molecular weight PAH) to an initial concentration of 500
mg/kg dried soil each. The effectiveness of process parameters
H2O2/soil, iron/soil, chelating agent/soil weight ratios and reaction
time were studied using a 24 three level factorial design experiments.
Statistically significant quadratic models were developed using
Response Surface Methodology (RSM) for degrading PAHs from the
soil samples. Optimum operating condition was achieved at mild
range of H2O2/soil, iron/soil and chelating agent/soil weight ratios,
indicating cost efficient method for treating highly contaminated
lands.
Abstract: It is essential to have a uniform and calm flow field
for a settling tank to have high performance. In general, the
recirculation zones always occurred in sedimentation tanks. The
presence of these regions may have different effects. The nonuniformity
of the velocity field, the short-circuiting at the surface and
the motion of the jet at the bed of the tank that occurs because of the
recirculation in the sedimentation layer, are affected by the geometry
of the tank. There are some ways to decrease the size of these dead
zones, which would increase the performance. One of the ways is to
use a suitable baffle configuration. In this study, the presence of
baffle with different position has been investigated by a finite volume
method, with VOF (Volume of Fluid) model. Besides, the k-ε
turbulence model is used in the numerical calculations. The results
indicate that the best position of the baffle is obtained when the
volume of the recirculation region is minimized or is divided to
smaller part and the flow field trend to be uniform in the settling
zone.
Abstract: This paper aims to develop a NOx emission model of
an acid gas incinerator using Nelder-Mead least squares support
vector regression (LS-SVR). Malaysia DOE is actively imposing the
Clean Air Regulation to mandate the installation of analytical
instrumentation known as Continuous Emission Monitoring System
(CEMS) to report emission level online to DOE . As a hardware
based analyzer, CEMS is expensive, maintenance intensive and often
unreliable. Therefore, software predictive technique is often
preferred and considered as a feasible alternative to replace the
CEMS for regulatory compliance. The LS-SVR model is built based
on the emissions from an acid gas incinerator that operates in a LNG
Complex. Simulated Annealing (SA) is first used to determine the
initial hyperparameters which are then further optimized based on the
performance of the model using Nelder-Mead simplex algorithm.
The LS-SVR model is shown to outperform a benchmark model
based on backpropagation neural networks (BPNN) in both training
and testing data.
Abstract: Shortening of natural resources will impose greater
limitations of electric energy consumption in various fields including
water treatment technologies. Small water treatment installations
supplied with electric energy from solar sources are perfect example of
zero-emission technology. Possibility of solar energy application, as
one of the alternative energy resources for decontamination processes
is strongly dependent on geographical location. Various examples of
solar driven water purification systems are given and design of
solar-water treatment installation based on ozone for the geographical
conditions in Poland are presented.
Abstract: The forest fires in Thailand are annual occurrence which is the cause of air pollutions. This study intended to estimate the emission from forest fire during 2005-2009 using MODerateresolution Imaging Spectro-radiometer (MODIS) sensor aboard the Terra and Aqua satellites, experimental data, and statistical data. The forest fire emission is estimated using equation established by Seiler and Crutzen in 1982. The spatial and temporal variation of forest fire emission is analyzed and displayed in the form of grid density map. From the satellite data analysis suggested between 2005 and 2009, the number of fire hotspots occurred 86,877 fire hotspots with a significant highest (more than 80% of fire hotspots) in the deciduous forest. The peak period of the forest fire is in January to May. The estimation on the emissions from forest fires during 2005 to 2009 indicated that the amount of CO, CO2, CH4, and N2O was about 3,133,845 tons, 47,610.337 tons, 204,905 tons, and 6,027 tons, respectively, or about 6,171,264 tons of CO2eq. They also emitted 256,132 tons of PM10. The year 2007 was found to be the year when the emissions were the largest. Annually, March is the period that has the maximum amount of forest fire emissions. The areas with high density of forest fire emission were the forests situated in the northern, the western, and the upper northeastern parts of the country.
Abstract: The study site was located in Ratchaburi Province,
Thailand. Four experimental plots in dry dipterocarp forest (DDF)
and four plots in mixed deciduous forest (MDF) were set up to
estimate the above-ground biomass of tree, sapling and bamboo. The
allometry equations were used to investigate above-ground biomass
of these vegetation. Seedling and other understory were determined
using direct harvesting method. Carbon storage in above-ground
biomass was calculated based on IPCC 2006.
The results showed that the above-ground biomass of DDF at
20-40% slope,
Abstract: The design of methods of the 20 K large dimension cold shield used for infrared radiation demarcating in space environment simulation test were introduced in this paper. The cold shield were cooled by five G-M cryocoolers , and the dimension of the cold shield is the largest in our country.Cold shield installation and distribution and compensator for contraction on cooling were introduced detailedly. The temperature distribution and cool-down time of cold shield surface were also calculated and analysed in this paper. The design of cold shield resolves the difficulty of compensator for contraction on cooling successfully. Test results show that the actual technical performance indicators of cold shield met and exceeded the design requirements.
Abstract: Many studies have been conducted for derivation of
attenuation relationships worldwide, however few relationships have
been developed to use for the seismic region of Iranian plateau and
only few of these studies have been conducted for derivation of
attenuation relationships for parameters such as uniform duration.
Uniform duration is the total time during which the acceleration is
larger than a given threshold value (default is 5% of PGA). In this
study, the database was same as that used previously by Ghodrati
Amiri et al. (2007) with same correction methods for earthquake
records in Iran. However in this study, records from earthquakes with
MS< 4.0 were excluded from this database, each record has
individually filtered afterward, and therefore the dataset has been
expanded. These new set of attenuation relationships for Iran are
derived based on tectonic conditions with soil classification into rock
and soil. Earthquake parameters were chosen to be
hypocentral distance and magnitude in order to make it easier to use
the relationships for seismic hazard analysis. Tehran is the capital
city of Iran wit ha large number of important structures. In this study,
a probabilistic approach has been utilized for seismic hazard
assessment of this city. The resulting uniform duration against return
period diagrams are suggested to be used in any projects in the area.