Abstract: In this paper an analysis of blackouts in electric power
transmission systems is implemented using a model and studied in
simple networks with a regular topology. The proposed model
describes load demand and network improvements evolving on a
slow timescale as well as the fast dynamics of cascading overloads
and outages.
Abstract: Photovoltaic (PV) systems provides a viable means of
power generation for applications like powering residential
appliances, electrification of villages in rural areas, refrigeration and
water pumping. Photovoltaic-power generation is reliable. The
operation and maintenance costs are very low. Since Myanmar is a
land of plentiful sunshine, especially in central and southern regions
of the country, the solar energy could hopefully become the final
solution to its energy supply problem in rural area.
Abstract: A mobile ad hoc network is a network of mobile nodes
without any notion of centralized administration. In such a network,
each mobile node behaves not only as a host which runs applications
but also as a router to forward packets on behalf of others. Clustering
has been applied to routing protocols to achieve efficient
communications. A CH network expresses the connected relationship
among cluster-heads. This paper discusses the methods for
constructing a CH network, and produces the following results: (1)
The required running costs of 3 traditional methods for constructing a
CH network are not so different from each other in the static
circumstance, or in the dynamic circumstance. Their running costs in
the static circumstance do not differ from their costs in the dynamic
circumstance. Meanwhile, although the routing costs required for the
above 3 methods are not so different in the static circumstance, the
costs are considerably different from each other in the dynamic
circumstance. Their routing costs in the static circumstance are also
very different from their costs in the dynamic circumstance, and the
former is one tenths of the latter. The routing cost in the dynamic
circumstance is mostly the cost for re-routing. (2) On the strength of
the above results, we discuss new 2 methods regarding whether they
are tolerable or not in the dynamic circumstance, that is, whether the
times of re-routing are small or not. These new methods are revised
methods that are based on the traditional methods. We recommended
the method which produces the smallest routing cost in the dynamic
circumstance, therefore producing the smallest total cost.
Abstract: Movable power sources of proton exchange
membrane fuel cells (PEMFC) are the important research done in the
current fuel cells (FC) field. The PEMFC system control influences
the cell performance greatly and it is a control system for industrial
complex problems, due to the imprecision, uncertainty and partial
truth and intrinsic nonlinear characteristics of PEMFCs. In this paper
an adaptive PI control strategy using neural network adaptive Morlet
wavelet for control is proposed. It is based on a single layer feed
forward neural networks with hidden nodes of adaptive morlet
wavelet functions controller and an infinite impulse response (IIR)
recurrent structure. The IIR is combined by cascading to the network
to provide double local structure resulting in improving speed of
learning. The proposed method is applied to a typical 1 KW PEMFC
system and the results show the proposed method has more accuracy
against to MLP (Multi Layer Perceptron) method.
Abstract: Li1.5Al0.5Ti1.5 (PO4)3(LATP) has received much
attention as a solid electrolyte for lithium batteries. In this study, the
LATP solid electrolyte is prepared by the co-precipitation method
using Li3PO4 as a Li source. The LATP is successfully prepared and
the Li ion conductivities of bulk (inner crystal) and total (inner crystal
and grain boundary) are 1.1 × 10-3 and 1.1 × 10-4 S cm-1, respectively.
These values are comparable to the reported values, in which Li2C2O4
is used as the Li source. It is conclude that the LATP solid electrolyte
can be prepared by the co-precipitation method using Li3PO4 as the Li
source and this procedure has an advantage in mass production over
previous procedure using Li2C2O4 because Li3PO4 is lower price
reagent compared with Li2C2O4.
Abstract: In this paper the Analytic Network Process (ANP) is
applied to the selection of photovoltaic (PV) solar power projects.
These projects follow a long management and execution process
from plant site selection to plant start-up. As a consequence, there are
many risks of time delays and even of project stoppage.
In the case study presented in this paper a top manager of an
important Spanish company that operates in the power market has to
decide on the best PV project (from four alternative projects) to
invest based on risk minimization. The manager identified 50 project
execution delay and/or stoppage risks.
The influences among elements of the network (groups of risks
and alternatives) were identified and analyzed using the ANP
multicriteria decision analysis method. After analyzing the results the
main conclusion is that the network model can manage all the
information of the real-world problem and thus it is a decision
analysis model recommended by the authors. The strengths and
weaknesses ANP as a multicriteria decision analysis tool are also
described in the paper.
Abstract: Two-interconnected fluidized bed systems are widely used in various processes such as Fisher-Tropsch, hot gas desulfurization, CO2 capture-regeneration with dry sorbent, chemical-looping combustion, sorption enhanced steam methane reforming, chemical-looping hydrogen generation system, and so on. However, most of two-interconnected fluidized beds systems require riser and/or pneumatic transport line for solid conveying and loopseals or seal-pots for gas sealing, recirculation of solids to the riser, and maintaining of pressure balance. The riser (transport bed) is operated at the high velocity fluidization condition and residence times of gas and solid in the riser are very short. If the reaction rate of catalyst or sorbent is slow, the riser can not ensure sufficient contact time between gas and solid and we have to use two bubbling beds for each reaction to ensure sufficient contact time. In this case, additional riser must be installed for solid circulation. Consequently, conventional two-interconnected fluidized bed systems are very complex, large, and difficult to operate. To solve these problems, a novel two-interconnected fluidized bed system has been developed. This system has two bubbling beds, solid injection nozzles, solid conveying lines, and downcomers. In this study, effects of operating variables on solid circulation rate, gas leakage between two beds have been investigated in a cold mode two-interconnected fluidized bed system. Moreover, long-term operation of continuous solid circulation up to 60 hours has been performed to check feasibility of stable operation.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. These methods can be
used to assess the transmission prices, but also to recover the
transmission fixed cost. In this paper is presented the influence of the
modification of commons structure has on the specific price of transfer
and on active power losses. The authors propose a power losses
allocation method, based on Kirschen-s method. The system operator
must make use of a few basic principles about allocation. The only
necessary information is the power flows on system branches and the
modifications applied to power system buses. In order to illustrate this
method, the 25-bus test system is used, elaborated within the Electrical
Power Engineering Department, from Timisoara, Romania.
Abstract: This paper presents an efficient emission constrained
hydrothermal scheduling algorithm that deals with nonlinear
functions such as the water discharge characteristics, thermal cost,
and transmission loss. It is then incorporated into the hydrothermal
coordination program. The program has been tested on a practical
utility system having 32 thermal and 12 hydro generating units. Test
results show that a slight increase in production cost causes a
substantial reduction in emission.
Abstract: As known that efficiency of photovoltaic cells is not
high as desired level. Efficiency of PVs could be improved by
selecting convenient locations that have high solar irradiation,
sunshine duration, mild temperature, low level air pollution and dust
concentration. Additionally, some environmental parameters called
derating factors effect to decrease PV efficiencies such as cloud, high
temperature, aerosol optical depth, high dust concentration, shadow,
snow, humidity etc. In this paper, all parameters that effect PV
efficiency are considered in detail under climatic conditions of
Istanbul. A 750 Wp PV system with measurement devices is
constructed in Maslak campus of Istanbul Technical University.
Abstract: This paper is proposed the dynamic simulation of
small power induction motor based on Mathematical modeling. The
dynamic simulation is one of the key steps in the validation of the
design process of the motor drive systems and it is needed for
eliminating inadvertent design mistakes and the resulting error in the
prototype construction and testing. This paper demonstrates the
simulation of steady-state performance of induction motor by
MATLAB Program Three phase 3 hp induction motor is modeled
and simulated with SIMULINK model.
Abstract: An effort to develop a unit commitment approach
capable of handling large power systems consisting of both thermal
and hydro generating units offers a large profitable return. In order to
be feasible, the method to be developed must be flexible, efficient
and reliable. In this paper, various proposed methods have been
described along with their strengths and weaknesses. As all of these
methods have some sort of weaknesses, a comprehensive algorithm
that combines the strengths of different methods and overcomes each
other-s weaknesses would be a suitable approach for solving
industry-grade unit commitment problem.
Abstract: Economic Load Dispatch (ELD) is a method of determining
the most efficient, low-cost and reliable operation of a power
system by dispatching available electricity generation resources to
supply load on the system. The primary objective of economic
dispatch is to minimize total cost of generation while honoring
operational constraints of available generation resources. In this paper
an intelligent water drop (IWD) algorithm has been proposed to
solve ELD problem with an objective of minimizing the total cost of
generation. Intelligent water drop algorithm is a swarm-based natureinspired
optimization algorithm, which has been inspired from natural
rivers. A natural river often finds good paths among lots of possible
paths in its ways from source to destination and finally find almost
optimal path to their destination. These ideas are embedded into
the proposed algorithm for solving economic load dispatch problem.
The main advantage of the proposed technique is easy is implement
and capable of finding feasible near global optimal solution with
less computational effort. In order to illustrate the effectiveness of
the proposed method, it has been tested on 6-unit and 20-unit test
systems with incremental fuel cost functions taking into account the
valve point-point loading effects. Numerical results shows that the
proposed method has good convergence property and better in quality
of solution than other algorithms reported in recent literature.
Abstract: Technology transfer of renewable energy technologies is very often unsuccessful in the developing world. Aside from challenges that have social, economic, financial, institutional and environmental dimensions, technology transfer has generally been misunderstood, and largely seen as mere delivery of high tech equipment from developed to developing countries or within the developing world from R&D institutions to society. Technology transfer entails much more, including, but not limited to: entire systems and their component parts, know-how, goods and services, equipment, and organisational and managerial procedures. Means to facilitate the successful transfer of energy technologies, including the sharing of lessons are subsequently extremely important for developing countries as they grapple with increasing energy needs to sustain adequate economic growth and development. Improving the success of technology transfer is an ongoing process as more projects are implemented, new problems are encountered and new lessons are learnt. Renewable energy is also critical to improve the quality of lives of the majority of people in developing countries. In rural areas energy is primarily traditional biomass. The consumption activities typically occur in an inefficient manner, thus working against the notion of sustainable development. This paper explores the implementation of technology transfer in the developing world (sub-Saharan Africa). The focus is necessarily on RETs since most rural energy initiatives are RETs-based. Additionally, it aims to highlight some lessons drawn from the cited RE projects and identifies notable differences where energy technology transfer was judged to be successful. This is done through a literature review based on a selection of documented case studies which are judged against the definition provided for technology transfer. This paper also puts forth research recommendations that might contribute to improved technology transfer in the developing world. Key findings of this paper include: Technology transfer cannot be complete without satisfying pre-conditions such as: affordability, maintenance (and associated plans), knowledge and skills transfer, appropriate know how, ownership and commitment, ability to adapt technology, sound business principles such as financial viability and sustainability, project management, relevance and many others. It is also shown that lessons are learnt in both successful and unsuccessful projects.
Abstract: Energy generated by the force of water in hydropower
can provide a more sustainable, non-polluting alternative to fossil
fuels, along with other renewable sources of energy, such as wind,
solar and tidal power, bio energy and geothermal energy. Small scale
hydroelectricity in Iran is well suited for “off-grid" rural electricity
applications, while other renewable energy sources, such as wind,
solar and biomass, can be beneficially used as fuel for pumping
groundwater for drinking and small scale irrigation in remote rural
areas or small villages. Small Hydro Power plants in Iran have very
low operating and maintenance costs because they consume no fossil
or nuclear fuel and do not involve high temperature processes. The
equipment is relatively simple to operate and maintain. Hydropower
equipment can adjust rapidly to load changes. The extended
equipment life provides significant economic advantages. Some
hydroelectric plants installed 100 years ago still operate reliably. The
Polkolo river is located on Karun basin at southwest of Iran. Situation
and conditions of Polkolo river are evaluated for construction of
small hydropower in this article. The topographical conditions and
the existence of permanent water from springs provide the suitability
to install hydroelectric power plants on the river Polkolo. The
cascade plant consists of 9 power plants connected with each other
and is having the total head as 1100m and discharge about 2.5cubic
meter per second. The annual production of energy is 105.5 million
kwh.
Abstract: This paper presents dynamic voltage collapse prediction on an actual power system using support vector machines.
Dynamic voltage collapse prediction is first determined based on the PTSI calculated from information in dynamic simulation output. Simulations were carried out on a practical 87 bus test system by considering load increase as the contingency. The data collected from the time domain simulation is then used as input to the SVM in which support vector regression is used as a predictor to determine the
dynamic voltage collapse indices of the power system. To reduce training time and improve accuracy of the SVM, the Kernel function type and Kernel parameter are considered. To verify the
effectiveness of the proposed SVM method, its performance is compared with the multi layer perceptron neural network (MLPNN). Studies show that the SVM gives faster and more accurate results for dynamic voltage collapse prediction compared with the MLPNN.
Abstract: The source voltage of high-power fuel cell shows strong load dependence at comparatively low voltage levels. In order to provide the voltage of 750V on the DC-link for feeding electrical energy into the mains via a three phase inverter a step-up converter with a large step-up ratio is required. The output voltage of this DC/DC-converter must be stabile during variations of the load current and the voltage of the fuel cell. This paper presents the methods and results of the calculation of the efficiency and the expense for the realization for the circuits of the DC/DC-converter that meet these requirements.
Abstract: At present, the severe oil crisis and greenhouse effect are booming, which is a growing worry for China. Over a long period of study, choosing the development of biological diesel is a feasible way in the desertification region in China. With considering the adaptability of Micro-algae in desertification region and analyzing energy consumption and carbon calculations of Micro-algae biodiesel produced by JJ company , this paper, make the microalgae our optimal choice to develop biological diesel in china's desertification region.
Abstract: Most of the losses in a power system relate to
the distribution sector which always has been considered.
From the important factors which contribute to increase losses
in the distribution system is the existence of radioactive flows.
The most common way to compensate the radioactive power
in the system is the power to use parallel capacitors. In
addition to reducing the losses, the advantages of capacitor
placement are the reduction of the losses in the release peak of
network capacity and improving the voltage profile. The point
which should be considered in capacitor placement is the
optimal placement and specification of the amount of the
capacitor in order to maximize the advantages of capacitor
placement.
In this paper, a new technique has been offered for the
placement and the specification of the amount of the constant
capacitors in the radius distribution network on the basis of
Genetic Algorithm (GA). The existing optimal methods for
capacitor placement are mostly including those which reduce
the losses and voltage profile simultaneously. But the
retaliation cost and load changes have not been considered as
influential UN the target function .In this article, a holistic
approach has been considered for the optimal response to this
problem which includes all the parameters in the distribution
network: The price of the phase voltage and load changes. So,
a vast inquiry is required for all the possible responses. So, in
this article, we use Genetic Algorithm (GA) as the most
powerful method for optimal inquiry.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. The methods can be used
to assess the transmission prices, but also to recover the transmission
fixed cost. In this paper is presented the influence of the modification of
commons structure has on the specific price of transfer. The operator
must make use of a few basic principles about allocation. Most
tracing methods are based on the proportional sharing principle. In this
paper Kirschen method is used. In order to illustrate this method, the 25-
bus test system is used, elaborated within the Electrical Power
Engineering Department, from Timisoara, Romania.