Abstract: Heat pipe is considered to be applied as a passive system to remove residual heat that generated from reactor core when incident occur or from spent fuel storage pool. The objectives are to characterized the heat transfer phenomena, performance of heat pipe, and as a model for large heat pipe will be applied as passive cooling system on nuclear spent fuel pool storage. In this experimental wickless heat pipe or two-phase closed thermosyphon (TPCT) is used. Variation of heat flux are 611.24 Watt/m2 - 3291.29 Watt/m2. Variation of filling ratio are 45 - 70%. Variation of initial pressure are -62 to -74 cm Hg. Demineralized water is used as working fluid in the TPCT. The results showed that increasing of heat load leads to an increase of evaporation of the working fluid. The optimum filling ratio obtained for 60% of TPCT evaporator volume, and initial pressure variation gave different TPCT wall temperature characteristic. TPCT showed best performance with 60% filling ratio and can be consider to be applied as passive residual heat removal system or passive cooling system on spent fuel storage pool.
Abstract: The aim of this research is to design a LHP with low thermal resistance and low condenser temperature. A Self-designed cascade LHP was tested by using biomaterial, sintered copper powder, and aluminum screen mesh as the wick. Using pure water as the working fluid for the first level of the LHP and 96% alcohol as the working fluid for the second level of LHP, the experiments were run with 10W, 20W, and 30W heat input. Experimental result shows that the usage of biomaterial as wick could reduce more temperature at evaporator than by using sintered copper powder and screen mesh up to 22.63% and 37.41% respectively. The lowest thermal resistance occurred during the usage of biomaterial as wick of heat pipe, which is 2.06 oC/W. The usage of cascade system could be applied to LHP to reduce the temperature at condenser and reduced thermal resistance up to 17.6%.
Abstract: The development of electric vehicle batteries have
resulted in very high energy density lithium-ion batteries. However,
this progress is accompanied by the risk of thermal runaway, which
can result in serious accidents. Heat pipes are heat exchangers that
are suitable to be applied in electric vehicle battery thermal
management for their lightweight, compact size and do not require
external power supply. This paper aims to examine experimentally a
Flat Plate Loop Heat Pipe (FPLHP) performance as a heat exchanger
in thermal management system of lithium-ion battery for electric
vehicle application. The heat generation of the battery was simulated
using a cartridge heater. Stainless steel screen mesh was used as the
capillary wick. Distilled water, alcohol and acetone were used as
working fluids with a filling ratio of 60%. It was found that acetone
gives the best performance that produces thermal resistance of 0.22
W/°C with 50°C evaporator temperature at heat flux load of 1.61
W/cm2.