Abstract: Anaerobic digestion process is one of the alternative
methods to convert organic waste into methane gas which is a fuel
and energy source. Activities of various kinds of microorganisms are
the main factor for anaerobic digestion which produces methane gas.
Therefore, in this study a modified Anaerobic Baffled Reactor (ABR)
with working volume of 50 liters was designed to identify the
microorganisms through biogas production. The mixture of 75%
kitchen waste and 25% sewage sludge was used as substrate.
Observations on microorganisms in the ABR showed that there exists
a small amount of protozoa (5%) and fungi (2%) in the system, but
almost 93% of the microorganism population consists of bacteria. It
is definitely clear that bacteria are responsible for anaerobic
biodegradation of kitchen waste. Results show that in the
acidification zone of the ABR (front compartments of reactor) fast
growing bacteria capable of growth at high substrate levels and
reduced pH was dominant. A shift to slower growing scavenging
bacteria that grow better at higher pH was occurring towards the end
of the reactor. Due to the ability of activity in acetate environment the
percentages of Methanococcus, Methanosarcina and Methanotrix
were higher than other kinds of methane former in the system.
Abstract: Water hyacinth has been used in aquatic systems for
wastewater purification in many years worldwide. The role of water
hyacinth (Eichhornia crassipes) species in polishing nitrate and
phosphorus concentration from municipal wastewater treatment plant
effluent by phytoremediation method was evaluated. The objective
of this project is to determine the removal efficiency of water
hyacinth in polishing nitrate and phosphorus, as well as chemical
oxygen demand (COD) and ammonia. Water hyacinth is considered
as the most efficient aquatic plant used in removing vast range of
pollutants such as organic matters, nutrients and heavy metals. Water
hyacinth, also referred as macrophytes, were cultivated in the
treatment house in a reactor tank of approximately 90(L) x 40(W) x
25(H) in dimension and built with three compartments. Three water
hyacinths were placed in each compartments and water sample in
each compartment were collected in every two days. The plant
observation was conducted by weight measurement, plant uptake and
new young shoot development. Water hyacinth effectively removed
approximately 49% of COD, 81% of ammonia, 67% of phosphorus
and 92% of nitrate. It also showed significant growth rate at starting
from day 6 with 0.33 shoot/day and they kept developing up to 0.38
shoot/day at the end of day 24. From the studies conducted, it was
proved that water hyacinth is capable of polishing the effluent of
municipal wastewater which contains undesirable amount of nitrate
and phosphorus concentration.
Abstract: Cameron Highlands is a mountainous area subjected
to torrential tropical showers. It extracts 5.8 million liters of water
per day for drinking supply from its rivers at several intake points.
The water quality of rivers in Cameron Highlands, however, has
deteriorated significantly due to land clearing for agriculture,
excessive usage of pesticides and fertilizers as well as construction
activities in rapidly developing urban areas. On the other hand, these
pollution sources known as non-point pollution sources are diverse
and hard to identify and therefore they are difficult to estimate.
Hence, Geographical Information Systems (GIS) was used to provide
an extensive approach to evaluate landuse and other mapping
characteristics to explain the spatial distribution of non-point sources
of contamination in Cameron Highlands. The method to assess
pollution sources has been developed by using Cameron Highlands
Master Plan (2006-2010) for integrating GIS, databases, as well as
pollution loads in the area of study. The results show highest annual
runoff is created by forest, 3.56 × 108 m3/yr followed by urban
development, 1.46 × 108 m3/yr. Furthermore, urban development
causes highest BOD load (1.31 × 106 kgBOD/yr) while agricultural
activities and forest contribute the highest annual loads for
phosphorus (6.91 × 104 kgP/yr) and nitrogen (2.50 × 105 kgN/yr),
respectively. Therefore, best management practices (BMPs) are
suggested to be applied to reduce pollution level in the area.