Abstract: The physical effects of upstream flow obstructions such
as vegetation on cross-ventilation phenomena of a building are
important for issues such as indoor thermal comfort. Modelling such
effects in Computational Fluid Dynamics simulations may also be
challenging. The aim of this work is to establish the cross-ventilation
jet behaviour in such complex terrain conditions as well as to provide
guidelines on the implementation of CFD numerical simulations in
order to model complex terrain features such as vegetation in an
efficient manner. The methodology consists of onsite measurements
on a test cell coupled with numerical simulations. It was found
that the cross-ventilation flow is highly turbulent despite the very
low velocities encountered internally within the test cells. While no
direct measurement of the jet direction was made, the measurements
indicate that flow tends to be reversed from the leeward to the
windward side. Modelling such a phenomenon proves challenging
and is strongly influenced by how vegetation is modelled. A solid
vegetation tends to predict better the direction and magnitude of the
flow than a porous vegetation approach. A simplified terrain model
was also shown to provide good comparisons with observation. The
findings have important implications on the study of cross-ventilation
in complex terrain conditions since the flow direction does not remain
trivial, as with the traditional isolated building case.
Abstract: The rapid growth of renewable energy sources and their integration into the grid have been motivated by the depletion of fossil fuels and environmental issues. Unfortunately, the grid is unable to cope with the predicted growth of renewable energy which would lead to its instability. To solve this problem, energy storage devices could be used. Electrolytic hydrogen production from an electrolyser is considered a promising option since it is a clean energy source (zero emissions). Choosing flexible operation of an electrolyser (producing hydrogen during the off-peak electricity period and stopping at other times) could bring about many benefits like reducing the cost of hydrogen and helping to balance the electric systems. This paper investigates the price of hydrogen during flexible operation compared with continuous operation, while serving the customer (hydrogen filling station) without interruption. The optimization algorithm is applied to investigate the hydrogen station in both cases (flexible and continuous operation). Three different scenarios are tested to see whether the off-peak electricity price could enhance the reduction of the hydrogen cost. These scenarios are: Standard tariff (1 tier system) during the day (assumed 12 p/kWh) while still satisfying the demand for hydrogen; using off-peak electricity at a lower price (assumed 5 p/kWh) and shutting down the electrolyser at other times; using lower price electricity at off-peak times and high price electricity at other times. This study looks at Derna city, which is located on the coast of the Mediterranean Sea (32° 46′ 0 N, 22° 38′ 0 E) with a high potential for wind resource. Hourly wind speed data which were collected over 24½ years from 1990 to 2014 were in addition to data on hourly radiation and hourly electricity demand collected over a one-year period, together with the petrol station data.