Abstract: Flexible AC transmission system controllers play an important role in controlling the line power flow and in improving voltage profiles of the power system network. They can be used to increase the reliability and efficiency of transmission and distribution system. The modeling of these FACTS controllers in power flow calculations have become a challenging research problem. This paper presents a simple and systematic approach for a steady state power flow calculations of power system with STATCOM (Static Synchronous Compensator). It shows how systematically STATCOM can be implemented in conventional power flow calculations. The main contribution of this paper is to investigate this approach for two special conditions i.e. consideration of load increase pattern incorporating load change (active, reactive and both active and reactive) at all load buses simultaneously and the line contingencies under such load change. Such investigation proves to be relevant for determination of strategy for the optimal placement of STATCOM to enhance the voltage stability. The performance has been evaluated on many standard IEEE test systems. The results for standard IEEE-30 bus test system are presented here.
Abstract: A microgrid (MG) is a small power grid composed of localized medium or low level power generation, storage systems, and loads. In this paper, the effects of a MG on power systems voltage stability are shown. The MG model, designed to demonstrate the effects of the MG, was applied to the IEEE 14 bus power system which is widely used in power system stability studies. Eigenvalue and modal analysis methods were used in simulation studies. In the study results, it is seen that MGs affect system voltage stability positively by increasing system voltage instability limit value for buses of a power system in which MG are placed.
Abstract: The installation of photovoltaic based distributed generation (PVDG) in active distribution system can lead to voltage fluctuation due to the intermittent and unpredictable PVDG output power. This paper presented a method in mitigating the voltage rise by optimally locating and sizing the battery energy storage system (BESS) in PVDG integrated distribution network. The improved firefly algorithm is used to perform optimal placement and sizing. Three objective functions are presented considering the voltage deviation and BESS off-time with state of charge as the constraint. The performance of the proposed method is compared with another optimization method such as the original firefly algorithm and gravitational search algorithm. Simulation results show that the proposed optimum BESS location and size improve the voltage stability.
Abstract: Many optimization techniques available in the literature have been developed in order to solve the problem of voltage stability enhancement in power systems. However, there are a number of drawbacks in the use of previous techniques aimed at determining the optimal location and size of reactive compensators in a network. In this paper, an Improved Cuckoo Search algorithm is applied as an appropriate optimization algorithm to determine the optimum location and size of a Static Var Compensator (SVC) in a transmission network. The main objectives are voltage stability improvement and total cost minimization. The results of the presented technique are then compared with other available optimization techniques.
Abstract: The alternating current is the main power in all industries and other aspects especially for the short and mid distances, but as far as long a distance which exceeds 500 KMs, using the alternating current technically will face many difficulties and more costs because it's difficult to control the current and also other restrictions. Therefore, recently those reasons led to building transmission lines HVDC to transmit power for long distances. This document presents technical comparison and assessments for power transmission system among distances either ways and studying the stability of the system regarding the proportion of losses in the actual power sent and received between both sides in different systems and also categorizing filters used in the HVDC system and its impact and effect on reducing Harmonic in the power transmission. MATLAB /Simulink simulation software is used to simulate both HVAC & HVDC power transmission system topologies.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: Due to the continuous increment of the load demand,
identification of weaker buses, improvement of voltage profile and
power losses in the context of the voltage stability problems has
become one of the major concerns for the larger, complex,
interconnected power systems. The objective of this paper is to
review the impact of Flexible AC Transmission System (FACTS)
controller in Wind generators connected electrical network for
maintaining voltage stability. Wind energy could be the growing
renewable energy due to several advantages. The influence of wind
generators on power quality is a significant issue; non uniform power
production causes variations in system voltage and frequency.
Therefore, wind farm requires high reactive power compensation; the
advances in high power semiconducting devices have led to the
development of FACTS. The FACTS devices such as for example
SVC inject reactive power into the system which helps in maintaining
a better voltage profile. The performance is evaluated on an IEEE 14
bus system, two wind generators are connected at low voltage buses
to meet the increased load demand and SVC devices are integrated at
the buses with wind generators to keep voltage stability. Power
flows, nodal voltage magnitudes and angles of the power network are
obtained by iterative solutions using MIPOWER.
Abstract: Based on the component approach, three kinds of
dynamic load models, including a single –motor model, a two-motor
model and composite load model have been developed for the
stability studies of Khuzestan power system. The study results are
presented in this paper. Voltage instability is a dynamic phenomenon
and therefore requires dynamic representation of the power system
components. Industrial loads contain a large fraction of induction
machines. Several models of different complexity are available for
the description investigations. This study evaluates the dynamic
performances of several dynamic load models in combination with
the dynamics of a load changing transformer. Case study is steel
industrial substation in Khuzestan power systems.
Abstract: The steady-state operation of maintaining voltage
stability is done by switching various controllers scattered all over
the power network. When a contingency occurs, whether forced or
unforced, the dispatcher is to alleviate the problem in a minimum
time, cost, and effort. Persistent problem may lead to blackout. The
dispatcher is to have the appropriate switching of controllers in terms
of type, location, and size to remove the contingency and maintain
voltage stability. Wrong switching may worsen the problem and that
may lead to blackout. This work proposed and used a Fuzzy CMeans
Clustering (FCMC) to assist the dispatcher in the decision
making. The FCMC is used in the static voltage stability to map
instantaneously a contingency to a set of controllers where the types,
locations, and amount of switching are induced.
Abstract: Analytical expression for maximum power transfer
through a transmission line limited by voltage stability has been
formulated using exact representation of transmission line with
ABCD parameters. The expression has been used for plotting PV
curve at different power factors of a radial transmission line.
Limiting values of reactive power have been obtained.
Abstract: Estimation of voltage stability based on optimal
filtering method is presented. PV curve is used as a tool for voltage stability analysis. Dynamic voltage stability estimation is done by
using particle filter method. Optimum value (nose point) of PV curve can be estimated by estimating parameter of PV curve equation
optimal value represents critical voltage and
condition at specified point of measurement. Voltage stability is then estimated by analyzing loading margin condition c stimating equation. This
maximum loading