Abstract: This study aims at improving the urban hydrological
cycle of the Orléans agglomeration (France) and understanding the
relationship between physical and chemical parameters of urban
surface runoff and the hydrological conditions. In particular water
quality parameters such as pH, conductivity, total dissolved solids,
major dissolved cations and anions, and chemical and biological
oxygen demands were monitored for three types of urban water
discharges (wastewater treatment plant output (WWTP), storm
overflow and stormwater outfall) under two hydrologic scenarios (dry
and wet weather). The first results were obtained over a period of five
months. Each investigated (Ormes, l’Egoutier and La Corne) outfall
represents an urban runoff source that receives water from runoff
roads, gutters, the irrigation of gardens and other sources of flow over
the Earth’s surface that drains in its catchments and carries it to the
Loire River. In wet weather conditions there is rain water runoff and
an additional input from the roof gutters that have entered the
stormwater system during rainfall. For the comparison the results La
Chilesse is a storm overflow that was selected in our study as a
potential source of waste water which is located before the (WWTP). The comparison of the physical-chemical parameters (total
dissolved solids, turbidity, pH, conductivity, dissolved organic
carbon (DOC), concentration of major cations and anions) together
with the chemical oxygen demand (COD) and biological oxygen
demand (BOD) helped to characterize sources of runoff waters in the
different watersheds. It also helped to highlight the infiltration of
wastewater in some stormwater systems that reject directly in the
Loire River. The values of the conductivity measured in the outflow
of Ormes were always higher than those measured in the other two
outlets. The results showed a temporal variation for the Ormes outfall
of conductivity from 1465 μS cm-1 in the dry weather flow to 650 μS
cm-1 in the wet weather flow and also a spatial variation in the wet
weather flow from 650 μS cm-1 in the Ormes outfall to 281 μS cm-1
in L’Egouttier outfall. The ultimate BOD (BOD28) showed a
significant decrease in La Corne outfall from 181 mg L-1 in the wet
weather flow to 95 mg L-1 in the dry weather flow because of the
nutrient load that was transported by the runoff.
Abstract: Urban runoff quality for a mixed residential-commercial land use catchment in Miri, Sarawak was investigated for three storm events in 2011. Samples from the three storm events were tested for five water quality parameters, namely, TSS, COD, BOD5, TP, and Pb. Concentration of the pollutants were found to vary significantly between storms, but were generally influenced by the length of antecedent dry period and the strength of rainfall intensities. Runoff from the study site showed a significant level of pollution for all the parameters investigated. Based on the National Water Quality Standards for Malaysia (NWQS), stormwater quality from the study site was polluted and exceeded class III water for TSS and BOD5, with maximum EMCs of 177 and 24 mg/L, respectively. Design pollutant load based on a design storm of 3-month average recurrence interval (ARI) for TSS, COD, BOD5, TP, and Pb were estimated to be 40, 9.4, 5.4, 1.7, and 0.06 kg/ha, respectively. The design pollutant load for the pollutants can be used to estimate loadings from similar catchments within Miri City.
Abstract: Urbanization has been found to impact stormwater
runoff quantity and quality. A study catchment with mixed land use,
residential and industrial were investigated and the water quality
discharged from the catchment were sampled and tested for four
basic water quality parameters; BOD5, NH3-N, NO3-N and P. One
dry weather flow and several stormwater runoff were sampled.
Results were compared to the USEPA stormwater quality benchmark
values and the Interim National Water Quality Standards for
Malaysia (INWQS). The concentration of the parameters was found
to vary significantly between storms and the pollutant of concern was
found to be NO3-N.
Abstract: Urban non-point source (NPS) pollution for a
residential catchment in Miri, Sarawak was investigated for two storm events in 2011. Runoff from two storm events were sampled and tested for water quality parameters including TSS, BOD5, COD,
NH3-N, NO3-N, NO2-N, P and Pb. Concentration of the water quality
parameters was found to vary significantly between storms and the pollutant of concern was found to be NO3-N, TSS, COD and Pb. Results were compared to the Interim National Water Quality
Standards for Malaysia (INWQS),and the stormwater runoff from the
study can be classified as polluted, exceeding class III water quality,
especially in terms of TSS, COD, and NH3-N with maximum EMCs
of 158, 135, and 2.17 mg/L, respectively.