Abstract: The purpose of this paper is to improve electromagnetic characteristics on grounding grid by applying the conductive concrete. The conductive concrete in this study is under an extra high voltage (EHV, 345kV) system located in a high-tech industrial park or science park. Instead of surrounding soil of grounding grid, the application of conductive concrete can reduce equipment damage and body damage caused by switching surges. The focus of the two cases on the EHV distribution system in a high-tech industrial park is presented to analyze four soil material styles. By comparing several soil material styles, the study results have shown that the conductive concrete can effectively reduce the negative damages caused by electromagnetic transient. The adoption of the style of grounding grid located 1.0 (m) underground and conductive concrete located from the ground surface to 1.25 (m) underground can obviously improve the electromagnetic characteristics so as to advance protective efficiency.
Abstract: The paper presents a one-dimensional transient
mathematical model of compressible thermal multi-component gas
mixture flows in pipes. The set of the mass, momentum and enthalpy
conservation equations for gas phase is solved. Thermo-physical
properties of multi-component gas mixture are calculated by solving
the Equation of State (EOS) model. The Soave-Redlich-Kwong
(SRK-EOS) model is chosen. Gas mixture viscosity is calculated on
the basis of the Lee-Gonzales-Eakin (LGE) correlation. Numerical
analysis on rapid decompression in conventional dry gases is
performed by using the proposed mathematical model. The model is
validated on measured values of the decompression wave speed in
dry natural gas mixtures. All predictions show excellent agreement
with the experimental data at high and low pressure. The presented
model predicts the decompression in dry natural gas mixtures much
better than GASDECOM and OLGA codes, which are the most
frequently-used codes in oil and gas pipeline transport service.
Abstract: Natural frequencies and dynamic response of a spur
gear sector are investigated using a two dimensional finite element
model that offers significant advantages for dynamic gear analyses.
The gear teeth are analyzed for different operating speeds. A primary
feature of this modeling is determination of mesh forces using a
detailed contact analysis for each time step as the gears roll through
the mesh. ANSYS software has been used on the proposed model to
find the natural frequencies by Block Lanczos technique and
displacements and dynamic stresses by transient mode super position
method. The effect of rotational speed of the gear on the dynamic
response of gear tooth has been studied and design limits have been
discussed.
Abstract: The new idea of analyze of power system failure with
use of artificial neural network is proposed. An analysis of the
possibility of simulating phenomena accompanying system faults and
restitution is described. It was indicated that the universal model for
the simulation of phenomena in whole analyzed range does not exist.
The main classic method of search of optimal structure and
parameter identification are described shortly. The example with
results of calculation is shown.
Abstract: The aim of this paper is to determine the stress levels
at the end of a long slender shaft such as a drilling assembly used in
the oil or gas industry using a mathematical model in real-time. The
torsional deflection experienced by this type of drilling shaft (about 4
KM length and 20 cm diameter hollow shaft with a thickness of 1
cm) can only be determined using a distributed modeling technique.
The main objective of this project is to calculate angular velocity and
torque at the end of the shaft by TLM method and also analyzing of
the behavior of the system by transient response. The obtained result
is compared with lumped modeling technique the importance of these
results will be evident only after the mentioned comparison. Two
systems have different transient responses and in this project because
of the length of the shaft transient response is very important.
Abstract: ELS is an important ground based hardware in the
loop simulator used for aerodynamics torque loading experiments
of the actuators under test. This work focuses on improvement of the
transient response of torque controller with parameters uncertainty
of Electrical Load Simulator (ELS).The parameters of load simulator
are estimated online and the model is updated, eliminating the model
error and improving the steady state torque tracking response of
torque controller. To improve the Transient control performance the
gain of robust term of SMC is updated online using fuzzy logic
system based on the amount of uncertainty in parameters of load
simulator. The states of load simulator which cannot be measured
directly are estimated using luenberger observer with update of new
estimated parameters. The stability of the control scheme is verified
using Lyapunov theorem. The validity of proposed control scheme is
verified using simulations.
Abstract: The mechanism of microwave heating is essentially
that of dielectric heating. After exposing the emulsion to the
microwave Electromagnetic (EM) field, molecular rotation and ionic
conduction due to the penetration of (EM) into the emulsion are
responsible for the internal heating. To determine the capability of
microwave technology in demulsification of crude oil emulsions,
microwave demulsification method was applied in a 50-50 % and 20-
80 % water-in-oil emulsions with microwave exposure time varied
from 20-180 sec. Transient temperature profiles of water-in-oil
emulsions inside a cylindrical container were measured. The
temperature rise at a given location was almost horizontal (linear).
The average rates of temperature increase of 50-50 % and 20-80 %
water-in-oil emulsions are 0.351 and 0.437 oC/sec, respectively. The
rate of temperature increase of emulsions decreased at higher
temperature due to decreasing dielectric loss of water. These results
indicate that microwave demulsification of water-in-oil emulsions
does not require chemical additions. Microwave has the potential to
be used as an alternative way in the demulsification process.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.
Abstract: This paper describes the development of a control
system model using a graphical software tool. This control system is
part of an operator training simulator developed for the National
Training Center for Operators of Ixtapantongo (CNCAOI, acronym
according to its name in Spanish language) of the Mexico-s Federal
Commission of Electricity, CFE). The Department of Simulation of
the Electrical Research Institute (IIE) developed this simulator using
as reference the Unit I of the Combined Cycle Power Plant El Sauz,
located at the centre of Mexico. The first step in the project was the
developing of the Gas Turbine System and its control system
simulator. The Turbo Gas simulator was finished and delivered to
CNCAOI in March 2007 for commercial operation. This simulator is
a high-fidelity real time dynamic simulator built and tested for
accurate operation over the entire load range. The simulator was used
primarily for operator training although it has been used for
procedure development and evaluation of plant transients.
Abstract: The paper shows that in the analysis of a queuing system with fixed-size batch arrivals, there emerges a set of polynomials which are a generalization of Chebyshev polynomials of the second kind. The paper uses these polynomials in assessing the transient behaviour of the overflow (equivalently call blocking) probability in the system. A key figure to note is the proportion of the overflow (or blocking) probability resident in the transient component, which is shown in the results to be more significant at the beginning of the transient and naturally decays to zero in the limit of large t. The results also show that the significance of transients is more pronounced in cases of lighter loads, but lasts longer for heavier loads.
Abstract: The application of a Static Synchronous Series Compensator (SSSC) controller to improve the transient stability performance of a power system is thoroughly investigated in this paper. The design problem of SSSC controller is formulated as an optimization problem and Particle Swarm Optimization (PSO) Technique is employed to search for optimal controller parameters. By minimizing the time-domain based objective function, in which the deviation in the oscillatory rotor angle of the generator is involved; transient stability performance of the system is improved. The proposed controller is tested on a weakly connected power system subjected to different severe disturbances. The non-linear simulation results are presented to show the effectiveness of the proposed controller and its ability to provide efficient damping of low frequency oscillations. It is also observed that the proposed SSSC controller improves greatly the voltage profile of the system under severe disturbances.
Abstract: The stability of Newtonian and Non-Newtonian extending films under local or global heating or cooling conditions are considered. The thickness-averaged mass, momentum and energy equations with convective and radiative heat transfer are derived, both for Newtonian and non-Newtonian fluids (Maxwell, PTT and Giesekus models considered). The stability of the system is explored using either eigenvalue analysis or transient simulations. The results showed that the influence of heating and cooling on stability strongly depends on the magnitude of the Peclet number. Examples of stabilization or destabilization of heating or cooling are shown for Pe
Abstract: Happening of Ferroresonance phenomenon is one of the reasons of consuming and ruining transformers, so recognition of Ferroresonance phenomenon has a special importance. A novel method for classification of Ferroresonance presented in this paper. Using this method Ferroresonance can be discriminate from other transients such as capacitor switching, load switching, transformer switching. Wavelet transform is used for decomposition of signals and Competitive Neural Network used for classification. Ferroresonance data and other transients was obtained by simulation using EMTP program. Using Daubechies wavelet transform signals has been decomposed till six levels. The energy of six detailed signals that obtained by wavelet transform are used for training and trailing Competitive Neural Network. Results show that the proposed procedure is efficient in identifying Ferroresonance from other events.
Abstract: Natural frequencies and dynamic response of a spur
gear sector are investigated using a two dimensional finite element
model that offers significant advantages for dynamic gear analyses.
The gear teeth are analyzed for different operating speeds. A primary
feature of this modeling is determination of mesh forces using a
detailed contact analysis for each time step as the gears roll through
the mesh. Transient mode super position method has been used to
find horizontal and vertical components of displacement and
dynamic stress. The finite element analysis software ANSYS has
been used on the proposed model to find the natural frequencies by
Block Lanczos technique and displacements and dynamic stresses by
transient mode super position method. A comparison of theoretical
(natural frequency and static stress) results with the finite element
analysis results has also been done. The effect of rotational speed of
the gears on the dynamic response of gear tooth has been studied and
design limits have been discussed.
Abstract: The transient hydrodynamics and thermal behaviors of
fluid flow in open-ended vertical parallel-plate porous microchannel are investigated semi-analytically under the effect of the hyperbolic
heat conduction model. The model that combines both the continuum approach and the possibility of slip at the boundary is adopted in the
study. The Effects of Knudsen number , Darcy number , and thermal relaxation time on the microchannel hydrodynamics and thermal behaviors are investigated using the hyperbolic heat
conduction models. It is found that as increases the slip in the hydrodynamic and thermal boundary condition increases. This slip in
the hydrodynamic boundary condition increases as increases. Also, the slip in the thermal boundary condition increases as
decreases especially the early stage of time.
Abstract: TiO2/MgO composite films were prepared by coating
the magnesium acetate solution in the pores of mesoporous TiO2
films using a dip coating method. Concentrations of magnesium
acetate solution were varied in a range of 1x10-4 – 1x10-1 M. The
TiO2/MgO composite films were characterized by scanning electron
microscopy (SEM), transmission electron microscropy (TEM),
electrochemical impedance spectroscopy(EIS) , transient voltage
decay and I-V test. The TiO2 films and TiO2/MgO composite films
were immersed in a 0.3 mM N719 dye solution. The Dye-sensitized
solar cells with the TiO2/MgO/N719 structure showed an optimal
concentration of magnesium acetate solution of 1x10-3 M resulting in
the MgO film estimated thickness of 0.0963 nm and giving the
maximum efficiency of 4.85%. The improved efficiency of dyesensitized
solar cell was due to the magnesium oxide film as the wide
band gap coating decays the electron back transfer to the triiodide
electrolyte and reduce charge recombination.
Abstract: The impact of fixed speed squirrel cage type as well as
variable speed doubly fed induction generators (DFIG) on dynamic
performance of a multimachine power system has been investigated.
Detailed models of the various components have been presented and
the integration of asynchronous and synchronous generators has been
carried out through a rotor angle based transform. Simulation studies
carried out considering the conventional dynamic model of squirrel
cage asynchronous generators show that integration, as such, could
degrade to the AC system performance transiently. This article
proposes a frequency or power controller which can effectively
control the transients and restore normal operation of fixed speed
induction generator quickly. Comparison of simulation results
between classical cage and doubly-fed induction generators indicate
that the doubly fed induction machine is more adaptable to
multimachine AC system. Frequency controller installed in the DFIG
system can also improve its transient profile.
Abstract: In this paper the authors propose and verify an approach to control heat flow in machine tool components. Thermal deformations are a main aspect that affects the accuracy of machining. Due to goals of energy efficiency, thermal basic loads should be reduced. This leads to inhomogeneous and time variant temperature profiles. To counteract these negative consequences, material with high melting enthalpy is used as a method for thermal stabilization. The increased thermal capacity slows down the transient thermal behavior. To account for the delayed thermal equilibrium, a control mechanism for thermal flow is introduced. By varying a gap in a heat flow path the thermal resistance of an assembly can be controlled. This mechanism is evaluated in two experimental setups. First to validate the ability to control the thermal resistance and second to prove the possibility of a self-sufficient option based on the selfsensing abilities of thermal shape memory alloys.
Abstract: Analysis for the generalized thermoelastic Lamb
waves, which propagates in anisotropic thin plates in generalized
thermoelasticity, is presented employing normal mode expansion
method. The displacement and temperature fields are expressed by a
summation of the symmetric and antisymmetric thermoelastic modes
in the surface thermal stresses and thermal gradient free orthotropic
plate, therefore the theory is particularly appropriate for waveform
analyses of Lamb waves in thin anisotropic plates. The transient
waveforms excited by the thermoelastic expansion are analyzed for
an orthotropic thin plate. The obtained results show that the theory
provides a quantitative analysis to characterize anisotropic
thermoelastic stiffness properties of plates by wave detection. Finally
numerical calculations have been presented for a NaF crystal, and the
dispersion curves for the lowest modes of the symmetric and
antisymmetric vibrations are represented graphically at different
values of thermal relaxation time. However, the methods can be used
for other materials as well
Abstract: A fully on-chip low drop-out (LDO) voltage regulator with 100pF output load capacitor is presented. A novel frequency compensation scheme using current buffer is adopted to realize single dominant pole within the unit gain frequency of the regulation loop, the phase margin (PM) is at least 50 degree under the full range of the load current, and the power supply rejection (PSR) character is improved compared with conventional Miller compensation. Besides, the differentiator provides a high speed path during the load current transient. Implemented in 0.18μm CMOS technology, the LDO voltage regulator provides 100mA load current with a stable 1.8V output voltage consuming 80μA quiescent current.