Abstract: The steel-concrete hybrid structure has been extensively employed in high-rise buildings and super high-rise buildings. The light gauge steel-concrete hybrid structure, including light gauge steel structure and concrete hybrid structure, is a type of steel-concrete hybrid structure, which possesses some advantages of light gauge steel structure and concrete hybrid structure. The seismic behavior and loss assessment of three high-rise buildings with three different concrete hybrid structures were investigated through finite element software. The three concrete hybrid structures are reinforced concrete column-steel beam (RC-S) hybrid structure, concrete-filled steel tube column-steel beam (CFST-S) hybrid structure, and tubed concrete column-steel beam (TC-S) hybrid structure. The nonlinear time-history analysis of three high-rise buildings under 80 earthquakes was carried out. After simulation, it indicated that the seismic performances of three high-rise buildings were superior. Under extremely rare earthquakes, the maximum inter-story drifts of three high-rise buildings are significantly lower than 1/50. The inter-story drift and floor acceleration of high-rise building with CFST-S hybrid structure were bigger than those of high-rise buildings with RC-S hybrid structure, and smaller than those of high-rise building with TC-S hybrid structure. Then, based on the time-history analysis results, the post-earthquake repair cost ratio and repair time of three high-rise buildings were predicted through an economic performance analysis method proposed in FEMA-P58 report. Under frequent earthquakes, basic earthquakes and rare earthquakes, the repair cost ratio and repair time of three high-rise buildings were less than 5% and 15 days, respectively. Under extremely rare earthquakes, the repair cost ratio and repair time of high-rise buildings with TC-S hybrid structure were the most among three high rise buildings. Due to the advantages of CFST-S hybrid structure, it could be extensively employed in high-rise buildings subjected to earthquake excitations.
Abstract: One of the main drawbacks of the Modal Pushover Analysis (MPA) is the need to perform nonlinear time-history analysis, which complicates the analysis method and time. A simplified version of the MPA has been proposed based on the concept of the inelastic deformation ratio. Furthermore, the effect of the higher modes of vibration is considered by assuming linearly-elastic responses, which enables the use of standard elastic response spectrum analysis. In this thesis, the simplified MPA (SMPA) method is applied to determine the target global drift and the inter-story drifts of steel frame building. The effect of the higher vibration modes is considered within the framework of the SMPA. A comprehensive survey about the inelastic deformation ratio is presented. After that, a suitable expression from literature is selected for the inelastic deformation ratio and then implemented in the SMPA. The estimated seismic demands using the SMPA, such as target drift, base shear, and the inter-story drifts, are compared with the seismic responses determined by applying the standard MPA. The accuracy of the estimated seismic demands is validated by comparing with the results obtained by the nonlinear time-history analysis using real earthquake records.
Abstract: This paper presents an analysis of the “Performance-Based” seismic design method, in order to overcome the perceived disadvantages and limitations of the existing seismic design approach based on force, in engineering practice. Bearing in mind, the specificity of the earthquake as a load and the fact that the seismic resistance of the structures solely depends on its behaviour in the nonlinear field, traditional seismic design approach based on force and linear analysis is not adequate. “Performance-Based” seismic design method is based on nonlinear analysis and can be used in everyday engineering practice. This paper presents the application of this method to eight-story high reinforced concrete building with combined structural system (reinforced concrete frame structural system in one direction and reinforced concrete ductile wall system in other direction). The nonlinear time-history analysis is performed on the spatial model of the structure using program Perform 3D, where the structure is exposed to forty real earthquake records. For considered building, large number of results were obtained. It was concluded that using this method we could, with a high degree of reliability, evaluate structural behavior under earthquake. It is obtained significant differences in the response of structures to various earthquake records. Also analysis showed that frame structural system had not performed well at the effect of earthquake records on soil like sand and gravel, while a ductile wall system had a satisfactory behavior on different types of soils.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: The seismic responses of steel buildings with semirigid
post-tensioned connections (PC) are estimated and compared
with those of steel buildings with typical rigid (welded) connections
(RC). The comparison is made in terms of global and local response
parameters. The results indicate that the seismic responses in terms of
interstory shears, roof displacements, axial load and bending
moments are smaller for the buildings with PC connection. The
difference is larger for global than for local parameters, which in turn
varies from one column location to another. The reason for this
improved behavior is that the buildings with PC dissipate more
hysteretic energy than those with RC. In addition, unlike the case of
buildings with WC, for the PC structures the hysteretic energy is
mostly dissipated at the connections, which implies that structural
damage in beams and columns is not significant. According to these
results, steel buildings with PC are a viable option in high seismicity
areas because of their smaller response and self-centering connection
capacity as well as the fact that brittle failure is avoided.
Abstract: The dome with ribs and rings, which covers the
ROMEXPO pavilion from Bucharest, was designed after the collapse
of the single layer reticulated dome. In this paper, it was made the
checking of the structure, under the dynamic loads with three
recorded accelerograms calibrated according to Romanian seismic
design code P100-1/2006. Under the action the dynamic loadings, it
was made a time-history analysis to determine the zones where the
plastic hinges appear, at what accelerations and their position on the
structure. The studied dome is formed by 32 spatial semi arches and
three rings: one circular ring located at the top of the dome and
another two rings, design as trusses, the first near the supports and the
second as an intermediate rings above the skylights. Above the
skylights up to the top, the dome is tight together with purlins and
bracings.
Abstract: This paper presents nonlinear elastic dynamic analysis
of 3-D semi-rigid steel frames including geometric and connection
nonlinearities. The geometric nonlinearity is considered by using
stability functions and updating geometric stiffness matrix. The
nonlinear behavior of the steel beam-to-column connection is
considered by using a zero-length independent connection element
comprising of six translational and rotational springs. The nonlinear
dynamic equilibrium equations are solved by the Newmark numerical
integration method. The nonlinear time-history analysis results are
compared with those of previous studies and commercial SAP2000
software to verify the accuracy and efficiency of the proposed
procedure.