Abstract: Composite metal–polymer materials, in particular titanium alloy (Ti-6Al-4V) to polyamide (PA6.6), fabricated by laser joining, have gained cogent interest among industries and researchers concerned with aerospace and biomedical applications. This work adopts infrared (IR) thermography technique to investigate effects of laser parameters used in the welding process on the three-dimensional temperature profile at the rear-side of titanium, at the region to be welded with polyamide. Cross sectional analysis of welded joints showed correlations between the morphology of titanium and polyamide at the weld zone with the corresponding temperature profile. In particular, spatial temperature profile was found to be correlated with the laser beam energy density, titanium molten pool width and depth, and polyamide heat affected zone depth.
Abstract: Diabetes is a medical condition that can lead to various diseases such as stroke, heart disease, blindness and obesity. In clinical practice, the concern of the diabetic patients towards the blood glucose examination is rather alarming as some of the individual describing it as something painful with pinprick and pinch. As for some patient with high level of glucose level, pricking the fingers multiple times a day with the conventional glucose meter for close monitoring can be tiresome, time consuming and painful. With these concerns, several non-invasive techniques were used by researchers in measuring the glucose level in blood, including ultrasonic sensor implementation, multisensory systems, absorbance of transmittance, bio-impedance, voltage intensity, and thermography. This paper is discussing the application of the near-infrared (NIR) spectroscopy as a non-invasive method in measuring the glucose level and the implementation of the linear system identification model in predicting the output data for the NIR measurement. In this study, the wavelengths considered are at the 1450 nm and 1950 nm. Both of these wavelengths showed the most reliable information on the glucose presence in blood. Then, the linear Autoregressive Moving Average Exogenous model (ARMAX) model with both un-regularized and regularized methods was implemented in predicting the output result for the NIR measurement in order to investigate the practicality of the linear system in this study. However, the result showed only 50.11% accuracy obtained from the system which is far from the satisfying results that should be obtained.
Abstract: Diagnosis of breast cancer at early stages has seen better clinical and survival outcomes. Survival rates in developing countries like India are very low due to accessibility and affordability issues of screening tests such as Mammography. In addition, Mammography is not much effective in younger women with dense breasts. This leaves a gap in current screening methods. Thermalytix is a new technique for detecting breast abnormality in a non-contact, non-invasive way. It is an AI-enabled computer-aided diagnosis solution that automates interpretation of high resolution thermal images and identifies potential malignant lesions. The solution is low cost, easy to use, portable and is effective in all age groups. This paper presents the results of a retrospective comparative analysis of Thermalytix over Mammography and Clinical Breast Examination for breast cancer screening. Thermalytix was found to have better sensitivity than both the tests, with good specificity as well. In addition, Thermalytix identified all malignant patients without palpable lumps.
Abstract: In the paper introduced the diagnostic technique making possible the research of internal structures in composite materials reinforced fibres using in different applications. The main reason of damages in structures of these materials is the changing distribution of load in constructions in the lifetime. Appearing defect is largely complicated because of the appearance of disturbing of continuity of reinforced fibres, binder cracks and loss of fibres adhesiveness from binders. Defect in composite materials is usually more complicated than in metals. At present, infrared thermography is the most effective method in non-destructive testing composite. One of IR thermography methods used in non-destructive evaluation is vibrothermography. The vibrothermography is not a new non-destructive method, but the new solution in this test is use ultrasonic waves to thermal stimulation of materials. In this paper, both modelling and experimental results which illustrate the advantages and limitations of ultrasonic IR thermography in inspecting composite materials will be presented. The ThermoSon computer program for computing 3D dynamic temperature distribuions in anisotropic layered solids with subsurface defects subject to ulrasonic stimulation was used to optimise heating parameters in the detection of subsurface defects in composite materials. The program allows for the analysis of transient heat conduction and ultrasonic wave propagation phenomena in solids. The experiments at MIAT were fulfilled by means of FLIR SC 7600 IR camera. Ultrasonic stimulation was performed with the frequency from 15 kHz to 30 kHz with maximum power up to 2 kW.
Abstract: In this work, different non-destructive testing methods for the characterization of defects and interfaces are presented. It is shown that, by means of active thermography, defects in the interface and in the carbon fiber reinforced polymer (CFRP) itself can be detected and determined. The bonding of metal and thermoplastic can be characterized very well by ultrasonic testing with electromagnetic acoustic transducers (EMAT). Mechanical testing is combined with passive thermography to correlate mechanical values with the defect-size. There is also a comparison between active and passive thermography. Mechanical testing shows the influence of different defects. Furthermore, a correlation of defect-size and loading to rupture was performed.
Abstract: Composite materials are one answer to the growing demand for materials with better parameters of construction and exploitation. Composite materials also permit conscious shaping of desirable properties to increase the extent of reach in the case of metals, ceramics or polymers. In recent years, composite materials have been used widely in aerospace, energy, transportation, medicine, etc. Fiber-reinforced composites including carbon fiber, glass fiber and aramid fiber have become a major structural material. The typical defect during manufacture and operation is delamination damage of layered composites. When delamination damage of the composites spreads, it may lead to a composite fracture. One of the many methods used in non-destructive testing of composites is active infrared thermography. In active thermography, it is necessary to deliver energy to the examined sample in order to obtain significant temperature differences indicating the presence of subsurface anomalies. To detect possible defects in composite materials, different methods of thermal stimulation can be applied to the tested material, these include heating lamps, lasers, eddy currents, microwaves or ultrasounds. The use of a suitable source of thermal stimulation on the test material can have a decisive influence on the detection or failure to detect defects. Samples of multilayer structure carbon composites were prepared with deliberately introduced defects for comparative purposes. Very thin defects of different sizes and shapes made of Teflon or copper having a thickness of 0.1 mm were screened. Non-destructive testing was carried out using the following sources of thermal stimulation, heating lamp, flash lamp, ultrasound and eddy currents. The results are reported in the paper.
Abstract: In orthopedic surgery there are various situations in
which the surgeon needs to implement methods of cutting and
drilling the bone. With this type of procedure the generated friction
leads to a localized increase in temperature, which may lead to the
bone necrosis. Recognizing the importance of studying this
phenomenon, an experimental evaluation of the temperatures
developed during the procedure of drilling bone has been done.
Additionally the influence of the use of the procedure with / without
additional lubrication during drilling of bone has also been done. The
obtained results are presented and discussed and suggests an
advantage in using additional lubrication as a way to minimize the
appearance of bone tissue necrosis during bone drilling procedures.
Abstract: The goal of this paper is to examine the effects of laser
radiation on the skin wound healing using infrared thermography as
non-invasive method for the monitoring of the skin temperature
changes during laser treatment. Thirty Wistar rats were used in this
study. A skin lesion was performed at the leg on all rats. The animals
were exposed to laser radiation (λ = 670 nm, P = 15 mW, DP = 16.31
mW/cm2) for 600 s. Thermal images of wound were acquired before
and after laser irradiation. The results have demonstrated that the
tissue temperature decreases from 35.5±0.50°C in the first treatment
day to 31.3±0.42°C after the third treatment day. This value is close
to the normal value of the skin temperature and indicates the end of
the skin repair process. In conclusion, the improvements in the
wound healing following exposure to laser radiation have been
revealed by infrared thermography.
Abstract: Constant amplitude fatigue crack growth (FCG) tests
were performed on dissimilar metal welded plates of Type 316L
Stainless Steel (SS) and IS 2062 Grade A Carbon steel (CS). The
plates were welded by TIG welding using SS E309 as electrode. FCG
tests were carried on the Side Edge Notch Tension (SENT)
specimens of 5 mm thickness, with crack initiator (notch) at base
metal region (BM), weld metal region (WM) and heat affected zones
(HAZ). The tests were performed at a test frequency of 10 Hz and at
load ratios (R) of 0.1 & 0.6. FCG rate was found to increase with
stress ratio for weld metals and base metals, where as in case of
HAZ, FCG rates were almost equal at high ΔK. FCG rate of HAZ of
stainless steel was found to be lowest at low and high ΔK. At
intermediate ΔK, WM showed the lowest FCG rate. CS showed
higher crack growth rate at all ΔK. However, the scatter band of data
was found to be narrow. Fracture toughness (Kc) was found to vary
in different locations of weldments. Kc was found lowest for the
weldment and highest for HAZ of stainless steel. A novel method of
characterizing the FCG behavior using an Infrared thermography
(IRT) camera was attempted. By monitoring the temperature rise at
the fast moving crack tip region, the amount of plastic deformation
was estimated.