Abstract: This paper explores steady-state characteristics of
grid-connected doubly fed induction motor (DFIM) in case of unity
power factor operation. Based on the synchronized mathematical
model, analytic determination of the control laws is presented and
illustrated by various figures to understand the effect of the applied
rotor voltage on the speed and the active power. On other hand,
unlike previous works where the stator resistance was neglected, in
this work, stator resistance is included such that the equations can be
applied to small wind turbine generators which are becoming more
popular. Finally the work is crowned by integration of the studied
induction generator in a wind system where an open loop control is
proposed confers a remarkable simplicity of implementation
compared to the known methods.
Abstract: The temperature distribution and the heat transfer
rates through a multi-layer door of a furnace were investigated. The
inside of the door was in contact with hot air and the other side of the
door was in contact with room air. Radiation heat transfer from the
walls of the furnace to the door and the door to the surrounding area
was included in the problem. This work is a two dimensional steady
state problem. The Churchill and Chu correlation was used to find
local convection heat transfer coefficients at the surfaces of the
furnace door. The thermophysical properties of air were the functions
of the temperatures. Polynomial curve fitting for the fluid properties
were carried out. Finite difference method was used to discretize for
conduction heat transfer within the furnace door. The Gauss-Seidel
Iteration was employed to compute the temperature distribution in
the door.
The temperature distribution in the horizontal mid plane of the
furnace door in a two dimensional problem agrees with the one
dimensional problem. The local convection heat transfer coefficients
at the inside and outside surfaces of the furnace door are exhibited.
Abstract: Petroleum refineries discharged large amount of
wastewater -during the refining process- that contains hazardous
constituents that is hard to degrade. Anaerobic treatment process is
well known as an efficient method to degrade high strength
wastewaters. Up-flow Anaerobic Sludge Blanker (UASB) is a
common process used for various wastewater treatments. Two UASB
reactors were set up and operated in parallel to evaluate the treatment
efficiency of petroleum refinery wastewater. In this study four
organic volumetric loading rates were applied (i.e. 0.58, 0.89, 1.21
and 2.34 kg/m3·d), two loads to each reactor. Each load was applied
for a period of 60 days for the reactor to acclimatize and reach steady
state, and then the second load applied. The chemical oxygen demand
(COD) removals were satisfactory with the removal efficiencies at the
loadings applied were 78, 82, 83 and 81 % respectively.
Abstract: In this work, the natural convection in a concentric
annulus between a cold outer inclined square enclosure and heated
inner circular cylinder is simulated for two-dimensional steady
state. The Boussinesq approximation was applied to model the
buoyancy-driven effect and the governing equations were solved
using the time marching approach staggered by body fitted
coordinates. The coordinate transformation from the physical
domain to the computational domain is set up by an analytical
expression. Numerical results for Rayleigh numbers 103 , 104 , 105
and 106, aspect ratios 1.5 , 3.0 and 4.5 for seven different
inclination angles for the outer square enclosure 0o , -30o
, -45o
,
-60o , -90o , -135o , -180o are presented as well. The computed flow
and temperature fields were demonstrated in the form of
streamlines, isotherms and Nusselt numbers variation. It is found
that both the aspect ratio and the Rayleigh number are critical to the
patterns of flow and thermal fields. At all Rayleigh numbers angle
of inclination has nominal effect on heat transfer.