Abstract: In this paper, all-optical signal processors that perform
both microwave mixing and bandpass filtering in a radio-over-fiber
(RoF) link are presented. The key device is a Mach-Zehnder
modulator (MZM) which performs all-optical microwave mixing. An
up-converted microwave signal is obtained and other unwanted
frequency components are suppressed at the end of the fiber span.
Abstract: This article presents the results using a parametric approach and a Wavelet Transform in analysing signals emitting from the sperm whale. The extraction of intrinsic characteristics of these unique signals emitted by marine mammals is still at present a difficult exercise for various reasons: firstly, it concerns non-stationary signals, and secondly, these signals are obstructed by interfering background noise. In this article, we compare the advantages and disadvantages of both methods: Auto Regressive models and Wavelet Transform. These approaches serve as an alternative to the commonly used estimators which are based on the Fourier Transform for which the hypotheses necessary for its application are in certain cases, not sufficiently proven. These modern approaches provide effective results particularly for the periodic tracking of the signal's characteristics and notably when the signal-to-noise ratio negatively effects signal tracking. Our objectives are twofold. Our first goal is to identify the animal through its acoustic signature. This includes recognition of the marine mammal species and ultimately of the individual animal (within the species). The second is much more ambitious and directly involves the intervention of cetologists to study the sounds emitted by marine mammals in an effort to characterize their behaviour. We are working on an approach based on the recordings of marine mammal signals and the findings from this data result from the Wavelet Transform. This article will explore the reasons for using this approach. In addition, thanks to the use of new processors, these algorithms once heavy in calculation time can be integrated in a real-time system.
Abstract: This paper describes a complex energy signal model
that is isomorphic with digital human fingerprint images. By using
signal models, the problem of fingerprint matching is transformed
into the signal processing problem of finding a correlation between
two complex signals that differ by phase-rotation and time-scaling. A
technique for minutiae matching that is independent of image
translation, rotation and linear-scaling, and is resistant to missing
minutiae is proposed. The method was tested using random data
points. The results show that for matching prints the scaling and
rotation angles are closely estimated and a stronger match will have a
higher correlation.
Abstract: Heart failure is the most common reason of death
nowadays, but if the medical help is given directly, the patient-s life
may be saved in many cases. Numerous heart diseases can be
detected by means of analyzing electrocardiograms (ECG). Artificial
Neural Networks (ANN) are computer-based expert systems that
have proved to be useful in pattern recognition tasks. ANN can be
used in different phases of the decision-making process, from
classification to diagnostic procedures. This work concentrates on a
review followed by a novel method.
The purpose of the review is to assess the evidence of healthcare
benefits involving the application of artificial neural networks to the
clinical functions of diagnosis, prognosis and survival analysis, in
ECG signals. The developed method is based on a compound neural
network (CNN), to classify ECGs as normal or carrying an
AtrioVentricular heart Block (AVB). This method uses three
different feed forward multilayer neural networks. A single output
unit encodes the probability of AVB occurrences. A value between 0
and 0.1 is the desired output for a normal ECG; a value between 0.1
and 1 would infer an occurrence of an AVB. The results show that
this compound network has a good performance in detecting AVBs,
with a sensitivity of 90.7% and a specificity of 86.05%. The accuracy
value is 87.9%.
Abstract: This work consists of three parts. First, the alias-free
condition for the conventional two-channel quadrature mirror filter
bank is analyzed using complex arithmetic. Second, the approach
developed in the first part is applied to the complex quadrature mirror
filter bank. Accordingly, the structure is simplified and the theory is
easier to follow. Finally, a new class of complex quadrature mirror
filter banks is proposed. Interesting properties of this new structure
are also discussed.
Abstract: This paper presents the design related to the
electronic system design of the respiratory signal, including phases
for processing, followed by the transmission and reception of this
signal and finally display. The processing of this signal is added to
the ECG and temperature sign, put up last year. Under this scheme is
proposed that in future also be conditioned blood pressure signal
under the same final printed circuit and worked.