Abstract: This paper presents the test results on 5 slab-column connection specimens with Ultra High Performance Fiber-Reinforced Concrete (UHPFRC) overlay including 1 control specimen to investigate retrofitting effect of UHPFRC overlay on the punching shear capacity. The test parameters were the thickness of the UHPFRC overlay and the amount of steel re-bars in it. All specimens failed in punching shear mode with abrupt failure aspect. The test results showed that by adding a thin layer of UHPFRC over the Reinforced Concrete (RC) substrates, considerable increases in global punching shear resistance up to 82% and structural rigidity were achieved. Furthermore, based on the cracking patterns the composite systems appeared to be governed by two failure modes: 1) diagonal shear failure in RC section and 2) debonding failure at the interface.
Abstract: Construction industry is making progress at a high pace. The trend of the world is getting more biased towards the high rise buildings. Deep beams are one of the most common elements in modern construction having small span to depth ratio. Deep beams are mostly used as transfer girders. This experimental study consists of 16 reinforced concrete (RC) deep beams. These beams were divided into two groups; A and B. Groups A and B consist of eight beams each, having 381 mm (15 in) and 457 mm (18 in) depth respectively. Each group was further subdivided into four sub groups each consisting of two identical beams. Each subgroup was comprised of solid/control beam (without opening), opening above neutral axis (NA), at NA and below NA. Except for control beams, all beams with openings were strengthened with carbon fibre reinforced polymer (CFRP) vertical strips. These eight groups differ from each other based on depth and location of openings. For testing sake, all beams have been loaded with two symmetrical point loads. All beams have been designed based on strut and tie model concept. The outcome of experimental investigation elaborates the difference in the shear behaviour of deep beams based on depth and location of circular openings variation. 457 mm (18 in) deep beam with openings above NA show the highest strength and 381 mm (15 in) deep beam with openings below NA show the least strength. CFRP sheets played a vital role in increasing the shear capacity of beams.
Abstract: This paper presents a proposed analytical model for predicting the shear strength of reinforced concrete beams strengthened with CFRP composites as external reinforcement. The proposed analytical model can predict the shear contribution of CFRP composites of RC beams with an acceptable coefficient of correlation with the tested results. Based on the comparison of the proposed model with the published well-known models (ACI model, Triantafillou model, and Colotti model), the ACI model had a wider range of 0.16 to 10.08 for the ratio between tested and predicted ultimate shears at failure. Also, an acceptable range of 0.27 to 2.78 for the ratio between tested and predicted ultimate shears by the Triantafillou model. Finally, the best prediction (the ratio between the tested and predicted ones) of the ultimate shear capacity is observed by using Colotti model with a range of 0.20 to 1.78. Thus, the contribution of the CFRP composites as external reinforcement can be predicted with high accuracy by using the proposed analytical model.
Abstract: Built-up columns have been widely employed by practice engineers in the design and construction of buildings and bridges. However, failures have been observed in this type of columns in previous seismic events. This study analyses the performance of built-up columns with different configurations of battens when it is subjected to seismic loads. Four columns with different size of battens were simulated and subjected to three different intensities of axial load along with a lateral cyclic load. Results indicate that the size of battens influences significantly the seismic behavior of columns. Lower shear capacity of battens results in higher ultimate strength and ductility for built-up columns. It is observed that intensity of axial load has a significant effect on the ultimate strength of columns, but it is less influential on the yield strength. For a given drift value, the stress level in the centroid of smaller size battens is significantly more than that of larger size battens signifying damage concentration in battens rather than chords. It is concluded that design of battens for shear demand lower than code specified values only slightly reduces initial stiffness of columns; however, it improves seismic performance of battened columns.
Abstract: So far, the conventional experimental and theoretical analysis in fracture mechanics have been applied to study concrete flexural- cracked beams, which are strengthened using fiber reinforced polymer (FRP) composite sheets. However, there is still little knowledge about the shear capacity of a side face FRP- strengthened shear-cracked beam. A numerical analysis is herein presented to model the fracture mechanics of a four-point RC beam, with two inclined initial notch on the supports, which is strengthened with side face FRP sheets. In the present study, the shear crack is forced to conduct by using an initial notch in supports. The ABAQUS software is used to model crack propagation by conventional cohesive elements. It is observed that the FRP sheets play important roles in preventing the propagation of shear cracks.
Abstract: The end panels of a large rectangular industrial duct,
which experience significant internal pressures, also experience
considerable transverse shear due to transfer of gravity loads to the
supports. The current design practice of such thin plate panels for
shear load is based on methods used for the design of plate girder
webs. The structural arrangements, the loadings and the resulting
behavior associated with the industrial duct end panels are, however,
significantly different from those of the web of a plate girder. The
large aspect ratio of the end panels gives rise to multiple bands of
tension fields, whereas the plate girder web design is based on one
tension field. In addition to shear, the industrial end panels are
subjected to internal pressure which in turn produces significant
membrane action. This paper reports a study which was undertaken
to review the current industrial analysis and design methods and to
propose a comprehensive method of designing industrial duct end
panels for shear resistance. In this investigation, a nonlinear finite element model was
developed to simulate the behavior of industrial duct end panel, along
with the associated edge stiffeners, subjected to transverse shear and
internal pressures. The model considered the geometric imperfections
and constitutive relations for steels. Six scale independent
dimensionless parameters that govern the behavior of such end panel
were identified and were then used in a parametric study. It was
concluded that the plate slenderness dominates the shear strength of
stockier end panels, and whereas, both the plate slenderness and the
aspect ratio influence the shear strength of slender end panels. Based
on these studies, this paper proposes design aids for estimating the
shear strength of rectangular duct end panels.
Abstract: Twin steel plates-concrete composite shear walls are
composed of a pair of steel plate layers and a concrete layer
sandwiched between them, which have the characteristics of both
reinforced concrete shear walls and steel plate shear walls. Twin steel
plates-composite shear walls contain very high ultimsate bearing
capacity and ductility, which have great potential to be applied in the
super high-rise buildings and special structures. In this paper, we
analyzed the basic characteristics and stress mechanism of the twin
steel plates-composite shear walls. Specifically, we analyzed the
effects of the steel plate thickness, wall thickness and concrete
strength on the bearing capacity of the twin steel plates-composite
shear walls. The analysis results indicate that: (1) the initial shear
stiffness and ultimate shear-carrying capacity is not significantly
affected by the thickness of concrete wall but by the class of concrete,
(2) both factors significantly impact the shear distribution of the
shear walls in ultimate shear-carrying capacity. The technique of twin
steel plates-composite shear walls has been successfully applied in
the construction of an 88-meter Huge Statue of Buddha located in
Hunan Province, China. The analysis results and engineering
experiences showed that the twin steel plates-composite shear walls
have great potential for future research and applications.
Abstract: Sandwich panels are widely used in the construction
industry for their ease of assembly, light weight and efficient thermal
performance. They are composed of two RC thin outer layers
separated by an insulating inner layer. In this research the inner
insulating layer is made of lightweight Autoclaved Aerated Concrete
(AAC) blocks which has good thermal insulation properties and yet
possess reasonable mechanical strength. The shear strength of the
AAC infill is relied upon to replace the traditionally used insulating
foam and to provide the shear capacity of the panel. A
comprehensive experimental program was conducted on full scale
sandwich panels subjected to bending. In this paper, detailed
numerical modeling of the tested sandwich panels is reported. Nonlinear
3-D finite element modeling of the composite action of the
sandwich panel is developed using ANSYS. Solid elements with
different crashing and cracking capabilities and different constitutive
laws were selected for the concrete and the AAC. Contact interface
elements are used in this research to adequately model the shear
transfer at the interface between the different layers. The numerical
results showed good correlation with the experimental ones
indicating the adequacy of the model in estimating the loading
capacity of panels.