Abstract: Fabric form-work is a technique to cast concrete structures with a great advantage of saving concrete material of up to 40%. This technique is particularly associated with the optimized concrete structures that usually have smaller cross-section dimensions than equivalent prismatic members. However, this can make the structural system produced from these members prone to smaller serviceability safety margins. Therefore, it is very important to understand the serviceability issue of non-prismatic concrete structures. In this paper, an analytical computer-based model to optimize concrete beams and to predict load-deflection behaviour of both prismatic and non-prismatic concrete beams is presented. The model was developed based on the method of sectional analysis and integration of curvatures. Results from the analytical model were compared to load-deflection behaviour of a number of beams with different geometric and material properties from other researchers. The results of the comparison show that the analytical program can accurately predict the load-deflection response of concrete beams with medium reinforcement ratios. However, it over-estimates deflection values for lightly reinforced specimens. Finally, the analytical program acceptably predicted load-deflection behaviour of on-prismatic concrete beams.
Abstract: This study is to evaluate the behavior of integral and
segmental specimens through static and cyclic tests. Integral
specimens were made with the same size to be compared with
segmental specimens that were made by connected precast members.
To evaluate its bending performance and serviceability, 1 integral and
3 segmental specimens were tested under static load. And 1 integral
and 2 segmental specimens were tested under cyclic load, respectively.
Different load ranges were considered in the cyclic tests to evaluate the
safety and serviceability. The test results showed that under static
loading, segmental specimens had about 94% of the integral
specimen's maximum moment, averagely. Under cyclic loading, the
segmental specimens showed that had enough safety in the range of
higher than service load and enough serviceability. In conclusion, the
maximum crack width (0.16mm) satisfied the allowable crack width
(0.30mm) in the range of service load.