Abstract: Magnetic Resonance Imaging Contrast Agents
(MRI-CM) are significant in the clinical and biological imaging as
they have the ability to alter the normal tissue contrast, thereby
affecting the signal intensity to enhance the visibility and detectability
of images. Superparamagnetic Iron Oxide (SPIO) nanoparticles,
coated with dextran or carboxydextran are currently available for
clinical MR imaging of the liver. Most SPIO contrast agents are
T2 shortening agents and Resovist (Ferucarbotran) is one of a
clinically tested, organ-specific, SPIO agent which has a low
molecular carboxydextran coating. The enhancement effect of
Resovist depends on its relaxivity which in turn depends on factors
like magnetic field strength, concentrations, nanoparticle properties,
pH and temperature. Therefore, this study was conducted to
investigate the impact of field strength and different contrast
concentrations on enhancement effects of Resovist. The study
explored the MRI signal intensity of Resovist in the physiological
range of plasma from T2-weighted spin echo sequence at three
magnetic field strengths: 0.47 T (r1=15, r2=101), 1.5 T (r1=7.4,
r2=95), and 3 T (r1=3.3, r2=160) and the range of contrast
concentrations by a mathematical simulation. Relaxivities of r1 and r2
(L mmol-1 Sec-1) were obtained from a previous study and the selected
concentrations were 0.05, 0.06, 0.07, 0.08, 0.09, 0.1, 0.2, 0.3, 0.4, 0.5,
0.6, 0.7, 0.8, 0.9, 1.0, 2.0, and 3.0 mmol/L. T2-weighted images were
simulated using TR/TE ratio as 2000 ms /100 ms. According to the
reference literature, with increasing magnetic field strengths, the
r1 relaxivity tends to decrease while the r2 did not show any
systematic relationship with the selected field strengths. In parallel,
this study results revealed that the signal intensity of Resovist at lower
concentrations tends to increase than the higher concentrations. The
highest reported signal intensity was observed in the low field strength
of 0.47 T. The maximum signal intensities for 0.47 T, 1.5 T and 3 T
were found at the concentration levels of 0.05, 0.06 and 0.05 mmol/L,
respectively. Furthermore, it was revealed that, the concentrations
higher than the above, the signal intensity was decreased
exponentially. An inverse relationship can be found between the field
strength and T2 relaxation time, whereas, the field strength was
increased, T2 relaxation time was decreased accordingly. However,
resulted T2 relaxation time was not significantly different between
0.47 T and 1.5 T in this study. Moreover, a linear correlation of
transverse relaxation rates (1/T2, s–1) with the concentrations of
Resovist can be observed. According to these results, it can conclude
that the concentration of SPIO nanoparticle contrast agents and the
field strengths of MRI are two important parameters which can affect the signal intensity of T2-weighted SE sequence. Therefore, when MR
imaging those two parameters should be considered prudently.
Abstract: Microcantilevers are the basic MEMS devices, which
can be used as sensors, actuators and electronics can be easily built
into them. The detection principle of microcantilever sensors is based
on the measurement of change in cantilever deflection or change in its
resonance frequency. The objective of this work is to explore the
analogies between mechanical and electrical equivalent of
microcantilever beams. Normally scientists and engineers working in
MEMS use expensive software like CoventorWare, IntelliSuite,
ANSYS/Multiphysics etc. This paper indicates the need of developing
electrical equivalent of the MEMS structure and with that, one can
have a better insight on important parameters, and their interrelation of
the MEMS structure. In this work, considering the mechanical model
of microcantilever, equivalent electrical circuit is drawn and using
force-voltage analogy, it is analyzed with circuit simulation software.
By doing so, one can gain access to powerful set of intellectual tools
that have been developed for understanding electrical circuits Later
the analysis is performed using ANSYS/Multiphysics - software based
on finite element method (FEM). It is observed that both mechanical
and electrical domain results for a rectangular microcantlevers are in
agreement with each other.
Abstract: In this paper, we calculate the two-photon ionization
(TPI) cross-section for pump-probe scheme in Ag neutral cluster. The
pump photon energy is assumed to be close to the surface plasmon
(SP) energy of cluster in dielectric media. Due to this choice, the
pump wave excites collective oscillations of electrons-SP and the
probe wave causes ionization of the cluster. Since the interband
transition energy in Ag exceeds the SP resonance energy, the main
contribution into the TPI comes from the latter. The advantage of Ag
clusters as compared to the other noble metals is that the SP
resonance in silver cluster is much sharper because of peculiarities of
its dielectric function. The calculations are performed by separating
the coordinates of electrons corresponding to the collective
oscillations and the individual motion that allows taking into account
the resonance contribution of excited SP oscillations. It is shown that
the ionization cross section increases by two orders of magnitude if
the energy of the pump photon matches the surface plasmon energy
in the cluster.
Abstract: This study was aimed to measure effective transverse
relaxation rates (R2*) in the liver and muscle of normal New Zealand
White (NZW) rabbits. R2* relaxation rate has been widely used in
various hepatic diseases for iron overload by quantifying iron contents
in liver. R2* relaxation rate is defined as the reciprocal of T2*
relaxation time and mainly depends on the constituents of tissue.
Different tissues would have different R2* relaxation rates. The signal
intensity decay in Magnetic resonance imaging (MRI) may be
characterized by R2* relaxation rates. In this study, a 1.5T GE Signa
HDxt whole body MR scanner equipped with an 8-channel high
resolution knee coil was used to observe R2* values in NZW rabbit’s
liver and muscle. Eight healthy NZW rabbits weighted 2 ~ 2.5 kg were
recruited. After anesthesia using Zoletil 50 and Rompun 2% mixture,
the abdomen of rabbit was landmarked at the center of knee coil to
perform 3-plane localizer scan using fast spoiled gradient echo
(FSPGR) pulse sequence. Afterwards, multi-planar fast gradient echo
(MFGR) scans were performed with 8 various echo times (TEs) to
acquire images for R2* measurements. Regions of interest (ROIs) at
liver and muscle were measured using Advantage workstation.
Finally, the R2* was obtained by a linear regression of ln(sı) on TE.
The results showed that the longer the echo time, the smaller the signal
intensity. The R2* values of liver and muscle were 44.8 ± 10.9 s-1 and
37.4 ± 9.5 s-1, respectively. It implies that the iron concentration of
liver is higher than that of muscle. In conclusion, the more the iron
contents in tissue, the higher the R2*. The correlations between R2*
and iron content in NZW rabbits might be valuable for further
exploration.
Abstract: Magnetic Resonance Imaging (MRI) is one of the
most important medical imaging modality. Subjective assessment of
the image quality is regarded as the gold standard to evaluate MR
images. In this study, a database of 210 MR images which contains
ten reference images and 200 distorted images is presented. The
reference images were distorted with four types of distortions: Rician
Noise, Gaussian White Noise, Gaussian Blur and DCT compression.
The 210 images were assessed by ten subjects. The subjective scores
were presented in Difference Mean Opinion Score (DMOS). The
DMOS values were compared with four FR-IQA metrics. We have
used Pearson Linear Coefficient (PLCC) and Spearman Rank Order
Correlation Coefficient (SROCC) to validate the DMOS values. The
high correlation values of PLCC and SROCC shows that the DMOS
values are close to the objective FR-IQA metrics.
Abstract: Cancer is still one of the serious diseases threatening
the lives of human beings. How to have an early diagnosis and
effective treatment for tumors is a very important issue. The animal
carcinoma model can provide a simulation tool for the studies of
pathogenesis, biological characteristics, and therapeutic effects.
Recently, drug delivery systems have been rapidly developed to
effectively improve the therapeutic effects. Liposome plays an
increasingly important role in clinical diagnosis and therapy for
delivering a pharmaceutic or contrast agent to the targeted sites.
Liposome can be absorbed and excreted by the human body, and is
well known that no harm to the human body. This study aimed to
compare the therapeutic effects between encapsulated (doxorubicin
liposomal, Lipodox) and un-encapsulated (doxorubicin, Dox)
anti-tumor drugs using magnetic resonance imaging (MRI).
Twenty-four New Zealand rabbits implanted with VX2 carcinoma at
left thighs were classified into three groups: control group (untreated),
Dox-treated group, and LipoDox-treated group, 8 rabbits for each
group. MRI scans were performed three days after tumor implantation.
A 1.5T GE Signa HDxt whole body MRI scanner with a high
resolution knee coil was used in this study. After a 3-plane localizer
scan was performed, three-dimensional (3D) fast spin echo (FSE)
T2-weighted Images (T2WI) was used for tumor volumetric
quantification. Afterwards, two-dimensional (2D) spoiled gradient
recalled echo (SPGR) dynamic contrast-enhanced (DCE) MRI was
used for tumor perfusion evaluation. DCE-MRI was designed to
acquire four baseline images, followed by contrast agent Gd-DOTA
injection through the ear vein of rabbit. A series of 32 images were
acquired to observe the signals change over time in the tumor and
muscle. The MRI scanning was scheduled on a weekly basis for a
period of four weeks to observe the tumor progression longitudinally.
The Dox and LipoDox treatments were prescribed 3 times in the first
week immediately after the first MRI scan; i.e. 3 days after VX2 tumor
implantation. ImageJ was used to quantitate tumor volume and time
course signal enhancement on DCE images. The changes of tumor size
showed that the growth of VX2 tumors was effectively inhibited for
both LipoDox-treated and Dox-treated groups. Furthermore, the tumor
volume of LipoDox-treated group was significantly lower than that of
Dox-treated group, which implies that LipoDox has better therapeutic effect than Dox. The signal intensity of LipoDox-treated group is
significantly lower than that of the other two groups, which implies
that targeted therapeutic drug remained in the tumor tissue. This study
provides a radiation-free and non-invasive MRI method for
therapeutic monitoring of targeted liposome on an animal tumor
model.
Abstract: Graphene, a single-atom sheet, has been considered as
the most promising material for making future nanoelectromechanical
systems as well as purely electrical switching with graphene
transistors. Graphene-based devices have advantages in scaled-up
device fabrication due to the recent progress in large area graphene
growth and lithographic patterning of graphene nanostructures. Here
we investigated its mechanical responses of circular graphene
nanoflake under the nanoindentation using classical molecular
dynamics simulations. A correlation between the load and the
indentation depth was constructed. The nanoindented force in this
work was applied to the center point of the circular graphene nanoflake
and then, the resonance frequency could be tuned by a nanoindented
depth. We found the hardening or the softening of the graphene
nanoflake during its nanoindented-deflections, and such properties
were recognized by the shift of the resonance frequency. The
calculated mechanical parameters in the force-vs-deflection plot were
in good agreement with previous experimental and theoretical works.
This proposed schematics can detect the pressure via the deflection
change or/and the resonance frequency shift, and also have great
potential for versatile applications in nanoelectromechanical systems.
Abstract: In this paper, we present an application of Riemannian
geometry for processing non-Euclidean image data. We consider the
image as residing in a Riemannian manifold, for developing a new
method to brain edge detection and brain extraction. Automating this
process is a challenge due to the high diversity in appearance brain
tissue, among different patients and sequences. The main contribution, in this paper, is the use of an edge-based
anisotropic diffusion tensor for the segmentation task by integrating
both image edge geometry and Riemannian manifold (geodesic,
metric tensor) to regularize the convergence contour and extract
complex anatomical structures. We check the accuracy of the
segmentation results on simulated brain MRI scans of single
T1-weighted, T2-weighted and Proton Density sequences. We
validate our approach using two different databases: BrainWeb
database, and MRI Multiple sclerosis Database (MRI MS DB). We
have compared, qualitatively and quantitatively, our approach with
the well-known brain extraction algorithms. We show that using
a Riemannian manifolds to medical image analysis improves the
efficient results to brain extraction, in real time, outperforming the
results of the standard techniques.
Abstract: The growth in the demand of electrical energy is
leading to load on the Power system which increases the occurrence
of frequent oscillations in the system. The reason for the oscillations
is due to the lack of damping torque which is required to dominate
the disturbances of Power system. By using FACT devices, such as
Unified Power Flow Controller (UPFC) can control power flow,
reduce sub-synchronous resonances and increase transient stability.
Hence, UPFC is used to damp the oscillations occurred in Power
system. This research focuses on adapting the neuro fuzzy controller
for the UPFC design by connecting the infinite bus (SMIB - Single
machine Infinite Bus) to a linearized model of synchronous machine
(Heffron-Phillips) in the power system. This model gains the
capability to improve the transient stability and to damp the
oscillations of the system.
Abstract: This paper aims to determine Fundamental Natural
Frequency (FNF) of a structural composite floor system known as
Chromite. To achieve this purpose, FNFs of studied panels are
determined by development of Finite Element Models (FEMs) in
ABAQUS program. American Institute of Steel Construction (AISC)
code in Steel Design Guide Series 11 presents a fundamental formula
to calculate FNF of a steel framed floor system. This formula has
been used to verify results of the FEMs. The variability in the FNF of
the studied system under various parameters such as dimensions of
floor, boundary conditions, rigidity of main and secondary beams
around the floor, thickness of concrete slab, height of composite
joists, distance between composite joists, thickness of top and bottom
flanges of the open web steel joists, and adding tie beam
perpendicular on the composite joists, is determined. The results
show that changing in dimensions of the system, its boundary
conditions, rigidity of main beam, and also adding tie beam,
significant changes the FNF of the system up to 452.9%, 50.8%, -
52.2%, %52.6%, respectively. In addition, increasing thickness of
concrete slab increases the FNF of the system up to 10.8%.
Furthermore, the results demonstrate that variation in rigidity of
secondary beam, height of composite joist, and distance between
composite joists, and thickness of top and bottom flanges of open
web steel joists insignificant changes the FNF of the studied system
up to -0.02%, -3%, -6.1%, and 0.96%, respectively. Finally, the
results of this study help designer predict occurrence of resonance,
comfortableness, and design criteria of the studied system.
Abstract: The shielding ability of a shielding cavity with an
aperture will be greatly degraded at resonance frequencies, and the
resonance modes and frequencies are affected by aperture resonances
and aperture-cavity coupling, which are closely related with aperture
sizes. The equivalent circuit method and numerical method of
Transmission Line Matrix (TLM) are used to analyze the effects of
aperture resonances and aperture-cavity coupling on the
electromagnetic resonances of a cavity with an aperture in this paper.
Both analytical and numerical results show that the resonance modes
of a shielding cavity with an aperture consist of cavity resonance
modes and aperture resonance modes, and the resonance frequencies
will shift with the change of the aperture sizes because of the aperture
resonances and aperture-cavity coupling. Variation rules of
electromagnetic resonances with aperture sizes for a cavity with an
aperture are given, which will be useful for design of shielding
cavities.
Abstract: The purpose of this study is to identify human walking vertical force by using FFT power spectrum density from the experimental acceleration data of the human body. An experiment on human walking is carried out on a stationary floor especially paying attention to higher components of dynamic vertical walking force. Based on measured acceleration data of the human lumbar part, not only in-phase component with frequency of 2fw, 3fw, but also in-opposite-phase component with frequency of 0.5 fw, 1.5 fw, 2.5 fw where fw is the walking rate is observed. The vertical vibration of pedestrian bridge induced by higher components of human walking vertical force is also discussed in this paper. A full scale measurement for the existing pedestrian bridge with center span length of 33 m is carried out focusing on the resonance phenomenon due to higher components of human walking vertical force. Dynamic response characteristics excited by these vertical higher components of human walking are revealed from the dynamic design viewpoint of pedestrian bridge.
Abstract: The objective of this paper is to evaluate the effects of
soil-structure interaction (SSI) on the modal characteristics and on
the dynamic response of current structures. The objective is on the
overall behaviour of a real structure of five storeys reinforced
concrete (R/C) building typically encountered in Algeria. Sensitivity
studies are undertaken in order to study the effects of frequency
content of the input motion, frequency of the soil-structure system,
rigidity and depth of the soil layer on the dynamic response of such
structures. This investigation indicated that the rigidity of the soil
layer is the predominant factor in soil-structure interaction and its
increases would definitely reduce the deformation in the R/C
structure. On the other hand, increasing the period of the underlying
soil will cause an increase in the lateral displacements at story levels
and create irregularity in the distribution of story shears. Possible
resonance between the frequency content of the input motion and soil
could also play an important role in increasing the structural
response.
Abstract: Low Temperature Matrix Isolation - Electron
Paramagnetic Resonance (LTMI-EPR) Spectroscopy was utilized to
identify the species of iron oxide nanoparticles generated during the
oxidative pyrolysis of 1-methylnaphthalene (1-MN). The otherwise
gas-phase reactions of 1--MN were impacted by a polypropylenimine
tetra-hexacontaamine dendrimer complexed with iron (III) nitrate
nonahydrate diluted in air under atmospheric conditions. The EPR
fine structure of Fe (III)2O3 nanoparticles clusters, characterized by gfactors
of 2.00, 2.28, 3.76 and 4.37 were detected on a cold finger
maintained at 77 K after accumulation over a multitude of
experiments. Additionally, a high valence Fe (IV) paramagnetic
intermediate and superoxide anion-radicals, O2•- adsorbed on
nanoparticle surfaces in the form of Fe (IV) --- O2•- were detected
from the quenching area of Zone 1 in the gas-phase.
Abstract: The spindle system is one of the most important
components of machine tool. The dynamic properties of the spindle
affect the machining productivity and quality of the work pieces.
Thus, it is important and necessary to determine its dynamic
characteristics of spindles in the design and development in order to
avoid forced resonance. The finite element method (FEM) has been
adopted in order to obtain the dynamic behavior of spindle system.
For this reason, obtaining the Campbell diagrams and determining the
critical speeds are very useful to evaluate the spindle system
dynamics. The unbalance response of the system to the center of
mass unbalance at the cutting tool is also calculated to investigate the
dynamic behavior. In this paper, we used an ANSYS Parametric
Design Language (APDL) program which based on finite element
method has been implemented to make the full dynamic analysis and
evaluation of the results. Results show that the calculated critical
speeds are far from the operating speed range of the spindle, thus, the
spindle would not experience resonance, and the maximum
unbalance response at operating speed is still with acceptable limit.
ANSYS Parametric Design Language (APDL) can be used by spindle
designer as tools in order to increase the product quality, reducing
cost, and time consuming in the design and development stages.
Abstract: In this paper, we present a new segmentation approach
for liver lesions in regions of interest within MRI (Magnetic
Resonance Imaging). This approach, based on a two-cluster Fuzzy CMeans
methodology, considers the parameter variable compactness
to handle uncertainty. Fine boundaries are detected by a local
recursive merging of ambiguous pixels with a sequential forward
floating selection with Zernike moments. The method has been tested
on both synthetic and real images. When applied on synthetic images,
the proposed approach provides good performance, segmentations
obtained are accurate, their shape is consistent with the ground truth,
and the extracted information is reliable. The results obtained on MR
images confirm such observations. Our approach allows, even for
difficult cases of MR images, to extract a segmentation with good
performance in terms of accuracy and shape, which implies that the
geometry of the tumor is preserved for further clinical activities (such
as automatic extraction of pharmaco-kinetics properties, lesion
characterization, etc.).
Abstract: In this study, nuclear magnetic resonance
spectroscopy and nuclear quadrupole resonance spectroscopy
parameters of 14N (Nitrogen in imidazole ring) in N–H…O hydrogen
bonding for Histidine hydrochloride monohydrate were calculated via
density functional theory. We considered a five-molecule model
system of Histidine hydrochloride monohydrate. Also we examined
the trends of environmental effect on hydrogen bonds as well as
cooperativity. The functional used in this research is M06-2X which
is a good functional and the obtained results has shown good
agreement with experimental data. This functional was applied to
calculate the NMR and NQR parameters. Some correlations among
NBO parameters, NMR and NQR parameters have been studied
which have shown the existence of strong correlations among them.
Furthermore, the geometry optimization has been performed using
M062X/6-31++G(d,p) method. In addition, in order to study
cooperativity and changes in structural parameters, along with
increase in cluster size, natural bond orbitals have been employed.
Abstract: This paper investigates the parametric stability of an
axially moving web subjected to non-uniform in-plane edge
excitations on two opposite, simply-supported edges. The web is
modeled as a viscoelastic plate whose constitutive relation obeys the
Kelvin-Voigt model, and the in-plane edge excitations are expressed
as the sum of a static tension and a periodical perturbation. Due to the
in-plane edge excitations, the moving plate may bring about
parametric instability under certain situations. First, the in-plane
stresses of the plate due to the non-uniform edge excitations are
determined by solving the in-plane forced vibration problem. Then,
the dependence on the spatial coordinates in the equation of transverse
motion is eliminated by the generalized Galerkin method, which
results in a set of discretized system equations in time. Finally, the
method of multiple scales is utilized to solve the set of system
equations analytically if the periodical perturbation of the in-plane
edge excitations is much smaller as compared with the static tension of
the plate, from which the stability boundaries of the moving plate are
obtained. Numerical results reveal that only combination resonances
of the summed-type appear under the in-plane edge excitations
considered in this work.
Abstract: Acoustic properties of polymeric liquids are high
sensitive to free gas traces in the form of fine bubbles. Their presence
is typical for such liquids because of chemical reactions, small
wettability of solid boundaries, trapping of air in technological
operations, etc. Liquid temperature influences essentially its
rheological properties, which may have an impact on the bubble
pulsations and sound propagation in the system. The target of the
paper is modeling of the liquid temperature effect on single bubble
dynamics and sound dispersion and attenuation in polymeric solution
with spherical gas bubbles. The basic sources of attenuation (heat
exchange between gas in microbubbles and surrounding liquid,
rheological and acoustic losses) are taken into account. It is supposed
that in the studied temperature range the interface mass transfer has a
minor effect on bubble dynamics. The results of the study indicate
that temperature raise yields enhancement of bubble pulsations and
increase in sound attenuation in the near-resonance range and may
have a strong impact on sound dispersion in the liquid-bubble
mixture at frequencies close to the resonance frequency of bubbles.
Abstract: Neural activity in the human brain starts from the
early stages of prenatal development. This activity or signals
generated by the brain are electrical in nature and represent not only
the brain function but also the status of the whole body. At the
present moment, three methods can record functional and
physiological changes within the brain with high temporal resolution
of neuronal interactions at the network level: the
electroencephalogram (EEG), the magnet oencephalogram (MEG),
and functional magnetic resonance imaging (fMRI); each of these has
advantages and shortcomings. EEG recording with a large number of
electrodes is now feasible in clinical practice. Multichannel EEG
recorded from the scalp surface provides very valuable but indirect
information about the source distribution. However, deep electrode
measurements yield more reliable information about the source
locations intracranial recordings and scalp EEG are used with the
source imaging techniques to determine the locations and strengths of
the epileptic activity. As a source localization method, Low
Resolution Electro-Magnetic Tomography (LORETA) is solved for
the realistic geometry based on both forward methods, the Boundary
Element Method (BEM) and the Finite Difference Method (FDM). In
this paper, we review the findings EEG- LORETA about epilepsy.