Abstract: This article is trying to determine the status of flue gas
that is entering the KWH heat exchanger from combustion chamber
in order to calculate the heat transfer ratio of the heat exchanger.
Combination of measurement, calculation and computer simulation
was used to create a useful way to approximate the heat transfer rate.
The measurements were taken by a number of sensors that are
mounted on the experimental device and by a thermal imaging
camera. The results of the numerical calculation are in a good
correspondence with the real power output of the experimental
device. That result shows that the research has a good direction and
can be used to propose changes in the construction of the heat
exchanger, but still needs enhancements.
Abstract: The integral form of equations of motion of composite
beams subjected to varying time loads are discretized using a
developed finite element model. The model consists of a straight five
node twenty-two degrees of freedom beam element. The stability
analysis of the beams is studied by solving the matrix form
characteristic equations of the system. The principle of virtual work
and the first order shear deformation theory are employed to analyze
the beams with large deformation and small strains. The regions of
dynamic instability of the beam are determined by solving the
obtained Mathieu form of differential equations. The effects of nonconservative
loads, shear stiffness, and damping parameters on
stability and response of the beams are examined. Several numerical
calculations are presented to compare the results with data reported
by other researchers.
Abstract: A power cable is widely used for power supply in
power distributing networks and power transmission lines. Due to
limitations in the production, delivery and setting up power cables,
they are produced and delivered in several separate lengths. Cable
itself, consists of two cable terminations and arbitrary number of
cable joints, depending on the cable route length. Electrical stress
control is needed to prevent a dielectric breakdown at the end of the
insulation shield in both the air and cable insulation. Reliability of
cable joint depends on its materials, design, installation and operating
environment. The paper describes design and performance results for
new modeled cable joints. Design concepts, based on numerical
calculations, must be correct. An Equivalent Electrodes
Method/Boundary Elements Method-hybrid approach that allows
electromagnetic field calculations in multilayer dielectric media,
including inhomogeneous regions, is presented.