Abstract: It is architecturally accepted that building form and design is considered as one of the most important aspects in affecting indoor temperature. The total area of building plan might be identical, but the design will have a major influence on the total area of external walls. This will have a clear impact on the amount of heat exchange with outdoor. Moreover, it will affect the position and area of glazing system. This has not received enough consideration in research by the specialists, since most of the publications are highlighting the impact of building envelope in terms of physical heat transfer in buildings. This research will investigate the impact of orientation of various building forms in various climatic regions. It will be concluded that orientation and glazing to wall ratio were recognized to be the most effective variables despite the shape of the building. However, linear ad radial forms were found more appropriate shapes almost across the continent.
Abstract: This study addresses a concept of the Sustainable Building Environmental Model (SBEM) developed to optimize energy consumption in air conditioning and ventilation (ACV) systems without any deterioration of indoor environmental quality (IEQ). The SBEM incorporates two main components: an adaptive comfort temperature control module (ACT) and a new carbon dioxide demand control module (nDCV). These two modules take an innovative approach to maintain satisfaction of the Indoor Environmental Quality (IEQ) with optimum energy consumption; they provide a rational basis of effective control. A total of 2133 sets of measurement data of indoor air temperature (Ta), relative humidity (Rh) and carbon dioxide concentration (CO2) were conducted in some Hong Kong offices to investigate the potential of integrating the SBEM. A simulation was used to evaluate the dynamic performance of the energy and air conditioning system with the integration of the SBEM in an air-conditioned building. It allows us make a clear picture of the control strategies and performed any pre-tuned of controllers before utilized in real systems. With the integration of SBEM, it was able to save up to 12.3% in simulation of overall electricity consumption, and maintain the average carbon dioxide concentration within 1000ppm and occupant dissatisfaction in 20%.
Abstract: Energy consumption and users’ satisfaction were
compared in three LEED certified office buildings in turkey and an
office building in Egypt. The field studies were conducted in summer
2012. The measured environmental parameters in the four buildings
were indoor air temperature, relative humidity, CO2 percentage and
light intensity. The traditional building is located in Smart Village in
Abu Rawash, Cairo, Egypt. The building was studied for 7 days
resulting in 84 responds. The three rated buildings are in Istanbul;
Turkey. A Platinum LEED certified office building is owned by
BASF and gained a platinum certificate for new construction and
major renovation. The building was studied for 3 days resulting in 13
responds. A Gold LEED certified office building is owned by BASF
and gained a gold certificate for new construction and major
renovation. The building was studied for 2 days resulting in 10
responds. A silver LEED certified office building is owned by
Unilever and gained a silver certificate for commercial interiors. The
building was studied for 7 days resulting in 84 responds.
The results showed that all buildings had no significant difference
regarding occupants’ satisfaction with the amount of lighting, noise
level, odor and access to the outdoor view. There was significant
difference between occupants’ satisfaction in LEED certified
buildings and the traditional building regarding the thermal
environment and the perception of the general environment (colors,
carpet and decoration. The findings suggest that careful design could
lead to a certified building that enhances the thermal environment and
the perception of the indoor environment leading to energy
consumption without scarifying occupants’ satisfaction.
Abstract: Ventilation is a fundamental requirement for
occupant health and indoor air quality in buildings. Natural
ventilation can be used as a design strategy in free-running
buildings to:
• Renew indoor air with fresh outside air and lower room
temperatures at times when the outdoor air is cooler.
• Promote air flow to cool down the building structure
(structural cooling).
• Promote occupant physiological cooling processes
(comfort cooling).
This paper focuses on ways in which ventilation can
provide the mechanism for heat dissipation and cooling of the
building structure..It also discusses use of ventilation as a
means of increasing air movement to improve comfort when
indoor air temperatures are too high. The main influencing
factors and design considerations and quantitative guidelines
to help meet the design objectives are also discussed.
Abstract: The use of solar control film on windows as one of
solar passive strategies for building have becoming important and is
gaining recognition. Malaysia located close to equator is having
warm humid climate with long sunshine hours and abundant solar
radiation throughout the year. Hence, befitting solar control on
windows is absolutely necessary to capture the daylight whilst
moderating thermal impact and eliminating glare problems. This is
one of the energy efficient strategies to achieve thermal and visual
comfort in buildings. Therefore, this study was carried out to
investigate the effect of window solar controls on thermal and visual
performance of naturally ventilated buildings. This was conducted via
field data monitoring using a test building facility. Four types of
window glazing systems were used with three types of solar control
films. Data were analysed for thermal and visual impact with
reference to thermal and optical characteristics of the films. Results
show that for each glazing system, the surface temperature of
windows are influenced by the Solar Energy Absorption property, the
indoor air temperature are influenced by the Solar Energy
Transmittance and Solar Energy Reflectance, and the daylighting by
Visible Light Transmission and Shading Coefficient. Further
investigations are underway to determine the mathematical relation
between thermal energy and visual performance with the thermal and
optical characteristics of solar control films.
Abstract: According to the Auckland climate, building passive
design more focus on improving winter indoor thermal and health
conditions. Based on field study data of indoor air temperature and
relative humidity close to ceiling and floor of an insulated Auckland
townhouse with and without a whole home mechanical ventilation
system, this study is to analysis variation of indoor microclimate data
of an Auckland townhouse using or not using the mechanical
ventilation system to evaluate winter indoor thermal and health
conditions for the future house design with a mechanical ventilation
system.