Abstract: This paper examines the forced convection flow of
incompressible, electrically conducting viscous fluid past a sharp
wedge in the presence of heat generation or absorption with an
applied magnetic field. The system of partial differential equations
governing Falkner - Skan wedge flow and heat transfer is first
transformed into a system of ordinary differential equations using
similarity transformations which is later solved using an implicit
finite - difference scheme, along with quasilinearization technique.
Numerical computations are performed for air (Pr = 0.7) and
displayed graphically to illustrate the influence of pertinent physical
parameters on local skin friction and heat transfer coefficients and,
also on, velocity and temperature fields. It is observed that the
magnetic field increases both the coefficients of skin friction and heat
transfer. The effect of heat generation or absorption is found to be
very significant on heat transfer, but its effect on the skin friction is
negligible. Indeed, the occurrence of overshoot is noticed in the
temperature profiles during heat generation process, causing the
reversal in the direction of heat transfer.
Abstract: Heat transfer from two cam shape cylinder in side-byside
arrangement had been studied numerically.
The transverse gap between the centers of cylinders (T) is allowed
to vary to change the pitch ratio (T/Deq). The equivalent diameter of
the cylinder (Deq) is 27.6 mm and pitch ratio varies in range of
1≤T/Deq≤3. The Reynolds numbers based on equivalent circular
cylinder are within 50≤ Reeq≤150. Results show that Nusselt number
of cylinders increases about 1 to 36 percent when pitch ratio
increases from 1 to 3.
Abstract: In nature, electromagnetic fields always appear like
atmosphere static electric field, the earth's static magnetic field and
the wide-rang frequency electromagnetic field caused by lightening.
However, besides natural electromagnetic fields (EMF), today human
beings are mostly exposed to artificial electromagnetic fields due to
technology progress and outspread use of electrical devices. To
evaluate nuisance of EMF, it is necessary to know field intensity for
every frequency which appears and compare it with allowed values.
Low frequency EMF-s around transmission and distribution lines are
time-varying quasi-static electromagnetic fields which have
conservative component of low frequency electrical field caused by
charges and eddy component of low frequency magnetic field caused
by currents. Displacement current or field delay are negligible, so
energy flow in quasi-static EMF involves diffusion, analog like heat
transfer. Electrical and magnetic field can be analyzed separately.
This paper analysis the numerical calculations in ELF-400 software
of EMF in distribution substation in shopping center. Analyzing the
results it is possible to specify locations exposed to the fields and
give useful suggestion to eliminate electromagnetic effect or reduce it
on acceptable level within the non-ionizing radiation norms and
norms of protection from EMF.