Abstract: Extracting energy from biomass is an important alternative to produce different types of energy (heat, electricity, or both) assuring low pollution and better efficiency. It is a new yet reliable approach to reduce green gas emission by extracting methane from industry effluents and use it to power machinery. We focused in our project on using paper and mill effluents, treated in a UASB reactor. The methane produced is used in the factory’s power supply. The aim of this work is to develop an electronic system using Arduino platform connected to a gas sensor, to measure and display the curve of daily methane production on processing. The sensor will send the gas values in ppm to the Arduino board so that the later sends the RS232 hardware protocol. The code developed with processing will transform the values into a curve and display it on the computer screen.
Abstract: In this paper, we presented not only development technology of an explosion proof type and portable combustible gas leak detector but also algorithm to improve accuracy for measuring gas concentrations. The presented techniques are to apply the flame-proof enclosure and intrinsic safe explosion proof to an infrared gas leak detector at first in Korea and to improve accuracy using linearization recursion equation and Lagrange interpolation polynomial. Together, we tested sensor characteristics and calibrated suitable input gases and output voltages. Then, we advanced the performances of combustible gaseous detectors through reflecting demands of gas safety management fields. To check performances of two company's detectors, we achieved the measurement tests with eight standard gases made by Korea Gas Safety Corporation. We demonstrated our instruments better in detecting accuracy other than detectors through experimental results.
Abstract: This paper presents a design of a wireless read out system for tracking the frequency shift of the polymer coated piezoelectric micro electromechanical resonator due to gas absorption. The measure of this frequency shift indicates the percentage of a particular gas the sensor is exposed to. It is measured using an oscillator and an FPGA based frequency counter by employing the resonator as a frequency determining element in the oscillator. This system consists of a Gas Sensing Wireless Readout (GSWR) and an USB Wireless Transceiver (UWT). GSWR consists of an oscillator based on a trans-impedance sustaining amplifier, an FPGA based frequency readout, a sub 1GHz wireless transceiver and a micro controller. UWT can be plugged into the computer via USB port and function as a wireless module to transfer gas sensor data from GSWR to the computer through its USB port. GUI program running on the computer periodically polls for sensor data through UWT - GSWR wireless link, the response from GSWR is logged in a file for post processing as well as displayed on screen.
Abstract: The Figaro AM-1 sensor module which employs TGS
2600 model gas sensor in air quality assessment was used. The
system was coupled with a microprocessor that enables sensor
module to create warning message via telephone. This low cot sensor
system’s performance was compared with a DiagNose II commercial
electronic nose system. Both air quality sensor and electronic nose
system employ metal oxide chemical gas sensors. In the study
experimental setup, data acquisition methods for electronic nose
system, and performance of the low cost air quality system were
evaluated and explained.
Abstract: In this paper, we propose a system for preventing gas
risks through the use of wireless communication modules and
intelligent gas safety appliances. Our system configuration consists of
an automatic extinguishing system, detectors, a wall-pad, and a
microcomputer controlled micom gas meter to monitor gas flow and
pressure as well as the occurrence of earthquakes. The automatic fire
extinguishing system checks for both combustible gaseous leaks and
monitors the environmental temperature, while the detector array
measures smoke and CO gas concentrations. Depending on detected
conditions, the micom gas meter cuts off an inner valve and generates
a warning, the automatic fire-extinguishing system cuts off an external
valve and sprays extinguishing materials, or the sensors generate
signals and take further action when smoke or CO are detected.
Information on intelligent measures taken by the gas safety appliances
and sensors are transmitted to the wall-pad, which in turn relays this as
real time data to a server that can be monitored via an external network
(BcN) connection to a web or mobile application for the management
of gas safety. To validate this smart-home gas management system, we
field-tested its suitability for use in Korean apartments under several
scenarios.
Abstract: In the present work, hydrogen gas sensor of modest
sensitivity utilizing functionalized multiwalled carbon nanotubes
partially decorated with tin oxide nanoparticles (F-MWCNTs/SnO2)
has been fabricated. This sensing material was characterized by
scanning electron microscopy (SEM). In addition, a remarkable
finding was that the F-MWCNTs/SnO2 sensor shows good sensitivity
as compared to F-MWCNTs for low concentration (0.05-1% by
volume) of H2 gas. The fabricated sensors show complete resistance
recovery and good repeatability when exposed to H2 gas at the room
temperature conditions.
Abstract: This work reports on the fabrication of tin nanoclusters by sputtering and inert-gas condensation inside an ultra-high vacuum compatible system. This technique allows to fine tune the size and yield of nanoclusters by controlling the nanocluster source parameters. The produced nanoclusters are deposited on SiO2/Si substrate with pre-formed electrical electrodes to produce a nanocluster device. Those devices can be potentially used for gas sensor applications.
Abstract: We present an Electronic Nose (ENose), which is
aimed at identifying the presence of one out of two gases, possibly
detecting the presence of a mixture of the two. Estimation of the
concentrations of the components is also performed for a volatile
organic compound (VOC) constituted by methanol and acetone, for
the ranges 40-400 and 22-220 ppm (parts-per-million), respectively.
Our system contains 8 sensors, 5 of them being gas sensors (of the
class TGS from FIGARO USA, INC., whose sensing element is a tin
dioxide (SnO2) semiconductor), the remaining being a temperature
sensor (LM35 from National Semiconductor Corporation), a
humidity sensor (HIH–3610 from Honeywell), and a pressure sensor
(XFAM from Fujikura Ltd.).
Our integrated hardware–software system uses some machine
learning principles and least square regression principle to identify at
first a new gas sample, or a mixture, and then to estimate the
concentrations. In particular we adopt a training model using the
Support Vector Machine (SVM) approach with linear kernel to teach
the system how discriminate among different gases. Then we apply
another training model using the least square regression, to predict
the concentrations.
The experimental results demonstrate that the proposed
multiclassification and regression scheme is effective in the
identification of the tested VOCs of methanol and acetone with
96.61% correctness. The concentration prediction is obtained with
0.979 and 0.964 correlation coefficient for the predicted versus real
concentrations of methanol and acetone, respectively.
Abstract: In this work we report on preliminary analysis of a novel optoelectronic gas sensor based on an optical fiber integrated with a tetrakis(4-sulfonatophenyl)porphyrin (TPPS) thin film. The sensitive materials are selectively deposited on the core region of a fiber tip by UV light induced deposition technique. A simple and cheap process which can be easily extended to different porphyrin derivatives. When the TPPS film on the fiber tip is exposed to acid and/or base vapors, dramatic changes occur in the aggregation structure of the dye molecules in the film, from J- to H-type, resulting in a profound modification of their corresponding reflectance spectra. From the achieved experimental results it is evident that the presence of intense and narrow band peaks in the reflected spectra could be monitored to detect hazardous vapors.
Abstract: Nanocrystalline thin film of Na0.1V2O5.nH2O xerogel
obtained by sol gel synthesis was used as gas sensor. Gas sensing
properties of different gases such as hydrogen, petroleum and
humidity were investigated. Applying XRD and TEM the size of the
nanocrystals is found to be 7.5 nm. SEM shows a highly porous
structure with submicron meter-sized voids present throughout the
sample. FTIR measurement shows different chemical groups
identifying the obtained series of gels. The sample was n-type
semiconductor according to the thermoelectric power and electrical
conductivity. It can be seen that the sensor response curves from
130oC to 150oC show a rapid increase in sensitivity for all types of
gas injection, low response values for heating period and the rapid
high response values for cooling period. This result may suggest that
this material is able to act as gas sensor during the heating and
cooling process.
Abstract: Vertical ZnO nanowire array films were synthesized
based on aqueous method for sensing applications. ZnO nanowires
were investigated structurally using X-ray diffraction (XRD) and
scanning electron microscopy (SEM). The gas-sensing properties of
ZnO nanowires array films are studied. It is found that the ZnO
nanowires array film sensor exhibits excellent sensing properties
towards O2 and CO2 at 100 °C with the response time shorter than 5
s. High surface area / volume ratio of vertical ZnO nanowire and high
mobility accounts for the fast response and recovery. The sensor
response was measured in the range from 100 to 500 ppm O2 and CO2
in this study.
Abstract: The voltage/current characteristics and the effect of
NO2 gas on the electrical conductivity of a PbPc gas sensor array is
investigated. The gas sensor is manufactured using vacuum
deposition of gold electrodes on sapphire substrate with the leadphathalocyanine
vacuum sublimed on the top of the gold electrodes.
Two versions of the PbPc gas sensor array are investigated. The
tested types differ in the gap sizes between the deposited gold
electrodes. The sensors are tested at different temperatures to account
for conductivity changes as the molecular adsorption/desorption rate
is affected by heat. The obtained results found to be encouraging as
the sensors shoed stability and sensitivity towards low concentration
of applied NO2 gas.
Abstract: A composite made of plasma functionalized multiwall
carbon nanotubes (MWNTs) coated with SnO2 was synthesized by
sonochemical precipitation method. Thick layer of this
nanocomposite material was used as ethanol sensor at low
temperatures. The composite sensitivity for ethanol has increased by
a factor of 2 at room temperature and by a factor of 13 at 250°C in
comparison to that of pure SnO2. SEM image of nanocomposite
material showed MWNTs were embedded in SnO2 matrix and also a
higher surface area was observed in the presence of functionalized
MWNTs. Greatly improved sensitivity of the composite material to
ethanol can be attributed to new gas accessing passes through
MWNTs and higher specific surface area.
Abstract: The effect of SnO2 surface modification by Ag nanoclusters, synthesized by SILD method, on the operating characteristics of thin film gas sensors was studied and models for the promotional role of Ag additives were discussed. It was found that mentioned above approach can be used for improvement both the sensitivity and the rate of response of the SnO2-based gas sensors to CO and H2. At the same time, the presence of the Ag clusters on the surface of SnO2 depressed the sensor response to ozone.
Abstract: In this study, a low temperature sensor highly selective to CO in presence of methane is fabricated by using 4 nm SnO2 quantum dots (QDs) prepared by sonication assisted precipitation. SnCl4 aqueous solution was precipitated by ammonia under sonication, which continued for 2 h. A part of the sample was then dried and calcined at 400°C for 1.5 h and characterized by XRD and BET. The average particle size and the specific surface area of the SnO2 QDs as well as their sensing properties were compared with the SnO2 nano-particles which were prepared by conventional sol-gel method. The BET surface area of sonochemically as-prepared product and the one calcined at 400°C after 1.5 hr are 257 m2/gr and 212 m2/gr respectively while the specific surface area for SnO2 nanoparticles prepared by conventional sol-gel method is about 80m2/gr. XRD spectra revealed pure crystalline phase of SnO2 is formed for both as-prepared and calcined samples of SnO2 QDs. However, for the sample prepared by sol-gel method and calcined at 400°C SnO crystals are detected along with those of SnO2. Quantum dots of SnO2 show exceedingly high sensitivity to CO with different concentrations of 100, 300 and 1000 ppm in whole range of temperature (25- 350°C). At 50°C a sensitivity of 27 was obtained for 1000 ppm CO, which increases to a maximum of 147 when the temperature rises to 225°C and then drops off while the maximum sensitivity for the SnO2 sample prepared by the sol-gel method was obtained at 300°C with the amount of 47.2. At the same time no sensitivity to methane is observed in whole range of temperatures for SnO2 QDs. The response and recovery times of the sensor sharply decreases with temperature, while the high selectivity to CO does not deteriorate.