Abstract: The development of the agricultural sector in Ghana
has been reliant on the use of irrigation systems to ensure food
security. However, the manual operation of these systems has not
facilitated their maximum efficiency due to human limitations.
This paper seeks to address this problem by designing and
implementing an efficient, cost effective automated system which
monitors and controls the water flow of irrigation through
communication with an authorized operator via text messages. The
automatic control component of the system is timer based with an
Atmega32 microcontroller and a real time clock from the SM5100B
cellular module. For monitoring purposes, the system sends periodic
notification of the system on the performance of duty via SMS to the
authorized person(s). Moreover, the GSM based Irrigation
Monitoring and Control System saves time and labour and reduces
cost of operating irrigation systems by saving electricity usage and
conserving water.
Field tests conducted have proven its operational efficiency and
ease of assessment of farm irrigation equipment due to its costeffectiveness
and data logging capabilities.
Abstract: Renewable energy is derived from natural processes
that are replenished constantly. Included in the definition is
electricity and heat generated from solar, wind, ocean, hydropower,
biomass, geothermal resources, and bio-fuels and hydrogen derived
from renewable resources. Each of these sources has unique
characteristics which influence how and where they are used. This
paper presents the modeling the simulation of solar and hydro hybrid
energy sources in MATLAB/SIMULINK environment. It simulates
all quantities of Hybrid Electrical Power system (HEPS) such as AC
output current of the inverter that injected to the load/grid, load
current, grid current. It also simulates power output from PV and
Hydraulic Turbine Generator (HTG), power delivered to or from grid
and finally power factor of the inverter for PV, HTG and grid. The
proposed circuit uses instantaneous p-q (real-imaginary) power
theory.
Abstract: Ancillary services are support services which are
essential for humanizing and enhancing the reliability and security of
the electric power system. Reactive power ancillary service is one of
the important ancillary services in a restructured electricity market
which determines the cost of supplying ancillary services and finding
of how this cost would change with respect to operating decisions.
This paper presents a new formation that can be used to minimize the
Independent System Operator (ISO)’s total payment for reactive
power ancillary service. The modified power flow tracing algorithm
estimates the availability of reserve reactive power for ancillary
service. In order to find optimum reactive power dispatch,
Biogeography based optimization method (BPO) is proposed. Market
Reactive Clearing Price (MRCP) is then estimated and it encourages
generator companies (GENCOs) to participate in an ancillary service.
Finally, optimal weighting factor and real time utilization factor of
reactive power give the minimum ISO’s total payment. The
effectiveness of proposed design is verified using IEEE 30 bus
system.
Abstract: Load Forecasting plays a key role in making today's
and future's Smart Energy Grids sustainable and reliable. Accurate
power consumption prediction allows utilities to organize in advance
their resources or to execute Demand Response strategies more
effectively, which enables several features such as higher
sustainability, better quality of service, and affordable electricity
tariffs. It is easy yet effective to apply Load Forecasting at larger
geographic scale, i.e. Smart Micro Grids, wherein the lower available
grid flexibility makes accurate prediction more critical in Demand
Response applications. This paper analyses the application of
short-term load forecasting in a concrete scenario, proposed within the
EU-funded GreenCom project, which collect load data from single
loads and households belonging to a Smart Micro Grid. Three
short-term load forecasting techniques, i.e. linear regression, artificial
neural networks, and radial basis function network, are considered,
compared, and evaluated through absolute forecast errors and training
time. The influence of weather conditions in Load Forecasting is also
evaluated. A new definition of Gain is introduced in this paper, which
innovatively serves as an indicator of short-term prediction
capabilities of time spam consistency. Two models, 24- and
1-hour-ahead forecasting, are built to comprehensively compare these
three techniques.
Abstract: The Indian subcontinent is facing a massive challenge with regards to energy security in its member countries; to provide reliable electricity to facilitate development across various sectors of the economy and consequently achieve the developmental targets. The instability of the current precarious situation is observable in the frequent system failures and blackouts.
The deployment of interconnected electricity ‘Supergrid’ designed to carry huge quanta of power across the Indian sub-continent is proposed in this paper. Not only enabling energy security in the subcontinent it will also provide a platform for Renewable Energy Sources (RES) integration. This paper assesses the need and conditions for a Supergrid deployment and consequently proposes a meshed topology based on Voltage Source High Voltage Direct Current (VSC- HVDC) converters for the Supergrid modeling. Various control schemes for the control of voltage and power are utilized for the regulation of the network parameters. A 3 terminal Multi Terminal Direct Current (MTDC) network is used for the simulations.
Abstract: Surplus electricity can be converted into potential energy via pumped hydroelectric storage for future usage. Similarly, thermo-electric energy storage (TEES) uses heat pumps equipped with thermal storage to convert electrical energy into thermal energy; the stored energy is then converted back into electrical energy when necessary using a heat engine. The greatest advantage of this method is that, unlike pumped hydroelectric storage and compressed air energy storage, TEES is not restricted by geographical constraints. In this study, performance variation of the TEES according to the changes in cold-side storage temperature was investigated by simulation method.
Abstract: Accurate Short Term Load Forecasting (STLF) is essential for a variety of decision making processes. However, forecasting accuracy can drop due to the presence of uncertainty in the operation of energy systems or unexpected behavior of exogenous variables. Interval Type 2 Fuzzy Logic System (IT2 FLS), with additional degrees of freedom, gives an excellent tool for handling uncertainties and it improved the prediction accuracy. The training data used in this study covers the period from January 1, 2012 to February 1, 2012 for winter season and the period from July 1, 2012 to August 1, 2012 for summer season. The actual load forecasting period starts from January 22, till 28, 2012 for winter model and from July 22 till 28, 2012 for summer model. The real data for Iraqi power system which belongs to the Ministry of Electricity.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: The scope of this paper is to evaluate and compare the potential of LS-PV(Large Scale Photovoltaic Power Plant) power generation systems in the southern region of Libya at Al-Kufra for both stationary and tracking systems. A Microsoft Excel-VBA program has been developed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency of the system for stationary system and for tracking system. The results for energy production show that the total energy output is 114GWh/year for stationary system and 148GWh/year for tracking system. The average module efficiency for the stationary system is 16.6% and 16.2% for the tracking system.
The values of electricity generation capacity factor (CF) and solar capacity factor (SCF) for stationary system were found to be 26% and 62.5% respectively and 34% and 82% for tracking system. The GCR (Ground Cover Ratio) for a stationary system is 0.7, which corresponds to a tilt angle of 24°. The GCR for tracking system was found to be 0.12. The estimated ground area needed to build a 50MW PV plant amounts to approx. 0.55km2 for a stationary PV field constituted by HIT PV arrays and approx. 91MW/ km2. In case of a tracker PV field, the required ground area amounts approx.2.4km2 and approx. 20.5MW/ km2.
Abstract: Power quality has become a very important issue recently due to the impact on electricity suppliers, equipment manufacturers and customers. Power quality is described as the variation of voltage, current and frequency in a power system. Voltage magnitude is one of the major factors that determine the quality of power. Indeed, custom power technology, the low-voltage counterpart of the more widely known flexible ac transmission system (FACTS) technology, aimed at high-voltage power transmission applications, has emerged as a credible solution to solve many problems relating to power quality problems. There are various power quality problems such as voltage sags, swells, flickers, interruptions and harmonics etc. Active Power Filter (APF) is one of the custom power devices and can mitigate harmonics, reactive power and unbalanced load currents originating from load side. In this study, an extensive review of APF studies, the advantages and disadvantages of each introduced methods are presented. The study also helps the researchers to choose the optimum control techniques and power circuit configuration for APF applications.
Abstract: This paper presents an Artificial Neural Network based approach for short-term load forecasting and exactly for two days ahead. Two seasons have been discussed for Iraqi power system, namely summer and winter; the hourly load demand is the most important input variables for ANN based load forecasting. The recorded daily load profile with a lead time of 1-48 hours for July and December of the year 2012 was obtained from the operation and control center that belongs to the Ministry of Iraqi electricity.
The results of the comparison show that the neural network gives a good prediction for the load forecasting and for two days ahead.
Abstract: To avoid battery assisted tags with limited lifetime batteries, it is proposed here to replace them by energy harvesting
systems, able to feed from local environment. This would allow total
independence to RFID systems, very interesting for applications
where tag removal from its location is not possible. Example is here
described for luggage safety in airports, and is easily extendable to similar situation in terms of operation constraints. The idea is to fix
RFID tag with energy harvesting system not only to identify luggage
but also to supply an embedded microcontroller with a sensor
delivering luggage weight making it impossible to add or to remove
anything from the luggage during transit phases. The aim is to
optimize the harvested energy for such RFID applications, and to
study in which limits these applications are theoretically possible.
Proposed energy harvester is based on two energy sources:
piezoelectricity and electromagnetic waves, so that when the luggage
is moving on ground transportation to airline counters, the piezo
module supplies the tag and its microcontroller, while the RF module
operates during luggage transit thanks to readers located along the
way. Tag location on the luggage is analyzed to get best vibrations, as
well as harvester better choice for optimizing the energy supply
depending on applications and the amount of energy harvested during
a period of time. Effects of system parameters (RFID UHF
frequencies, limit distance between the tag and the antenna necessary
to harvest energy, produced voltage and voltage threshold) are
discussed and working conditions for such system are delimited.
Abstract: Utilizing solar energy in producing electricity can minimize environmental pollution generated by fossil fuel in producing electricity. Our research was base on the extraction of dye from Roystonea regia fruit by using methanol as solvent. The dye extracts were used as sensitizers in Dye-sensitized solar cell (DSSCs). Study was done on the electrical properties from the extracts of Roystonea regia fruit as Dye-sensitized solar cell (DSSCs). The absorptions of the extracts and extracts with dye were determined at different wavelengths (350-1000nm). Absorption peak was observed at 1.339 at wavelength 400nm. The obtained values for methanol extract Roystonea regia extract are, Imp = 0.015mA, Vmp = 12.0mV, fill factor = 0.763, Isc= 0.018 mA and Voc = 13.1 mV and efficiency of 0.32%. .The phytochemical screening was taken and it was observed that Roystonea regia extract contained less of anthocyanin compared to flavonoids. The nanostructured dye sensitized solar cell (DSSC) will provide economically credible alternative to present day silicon p–n junction photovoltaic.
Abstract: In this work, an experimental technique is applied
for the measurements of the vibrations and deformation of a test
transformer core. Since the grid voltage contains some higher
harmonics, in addition to a purely sinusoidal magnetisation of the
core the presence of third harmonic is also studied. The vibrations of
the transformer core for points as well as the surface scan of the leg
show more deformation in the corners of the leg than the middle of
the leg. The influence of the higher harmonic of the magnetisation
on the core deformation is also more significant in the corners of the
leg. The core deformation shape under a sinusoidal magnetisation
with a higher harmonic is more wavy and fluctuating than that under
a purely sinusoidal magnetisation.
Abstract: This paper presents the optimal design and simulation of a grid-connected Photovoltaic (PV) system to supply electric power to meet the energy demand by Electrical Department in University of Tripoli Libya. Solar radiation is the key factor determining electricity produced by photovoltaic (PV) systems. This paper is designed to develop a novel method to calculate the solar photovoltaic generation capacity on the basis of Mean Global Solar Radiation data available for Tripoli Libya and finally develop a system design of possible plant capacity for the available roof area. MatLab/Simulink Programming tools and monthly average solar radiation data are used for this design and simulation. The specifications of equipments are provided based on the availability of the components in the market. Simulation results and analyses are presented to validate the proposed system configuration.
Abstract: This paper presents the performance of electricity
generation and consumption from solar generator installed at
Rajabhat Suan Sunandha’s learning center in Samutsongkram.
The result from the experiment showed that solar cell began to
work and distribute the current into the system when the solar energy
intensity was 340 w/m2, starting from 8:00 am to 4:00 pm (duration
of 8 hours). The highest intensity read during the experiment was
1,051.64w/m2. The solar power was 38.74kWh/day. The
electromotive force from solar cell averagely was 93.6V. However,
when connecting solar cell with the battery charge controller system,
the voltage was dropped to 69.07V. After evaluating the power
distribution ability and electricity load of tested solar cell, the result
showed that it could generate power to 11 units of 36-watt
fluorescent lamp bulbs, which was altogether 396W. In the
meantime, the AC to DC power converter generated 3.55A to the
load, and gave 781VA.
Abstract: This paper presents a detailed description of evaporative cooling systems used for space cooling in Mina Valley, Saudi Arabia. The thermal performance and environmental impact of the evaporative coolers were evaluated. It was found that the evaporative cooling systems used for space cooling in pilgrims’ accommodations and in the train stations could reduce energy consumption by as much as 75% and cut carbon dioxide emission by 78% compared to traditional vapour compression systems.
Abstract: The Smart Grid Simulator is a computer software based on advance algorithms which has as the main purpose to lower the energy bill in the most optimized price efficient way as possible for private households, companies or energy providers. It combines the energy provided by a number of solar modules and wind turbines with the consumption of one household or a cluster of nearby households and information regarding weather conditions and energy prices in order to predict the amount of energy that can be produced by renewable energy sources and the amount of energy that will be bought from the distributor for the following day. The user of the system will not only be able to minimize his expenditures on energy factures, but also he will be informed about his hourly consumption, electricity prices fluctuation and money spent for energy bought as well as how much money he saved each day and since he installed the system. The paper outlines the algorithm that supports the Smart Grid Simulator idea and presents preliminary test results that supports the discussion and implementation of the system.
Abstract: Energy is required in almost every aspect of human activities and development of any nation in the world. Increasing fossil fuel price, energy security and climate change have important bearings on sustainable development of any nation. The renewable energy technology is considered one of the drastic approaches which taken over the world to reduce the energy problem. The preservation of vegetables by freezing is one of the most important methods of retaining quality in agricultural products over long-term storage periods. Freezing factories show high demand of energy for both heat and electricity; the hybrid Photovoltaic/Thermal (PV/T) systems could be used in order to meet this requirement. This paper presents PV/T system design for freezing factory. Also, the complete mathematical modeling and MATLAB SIMULINK of PV/T collector is introduced. The sensitivity analysis for the manufacturing parameters of PV/T collector is carried out to study their effect on both thermal and electrical efficiency.
Abstract: With the objective of characterizing the profile and performance of energy use by slaughterhouses, surveys and audits were performed in two different facilities located in the northeastern region of Portugal. Energy consumption from multiple energy sources was assessed monthly, along with production and costs, for the same reference year. Gathered data was analyzed to identify and quantify the main consuming processes and to estimate energy efficiency indicators for benchmarking purposes. Main results show differences between the two slaughterhouses concerning energy sources, consumption by source and sector, and global energy efficiency. Electricity is the most used source in both slaughterhouses with a contribution of around 50%, being essentially used for meat processing and refrigeration. Natural gas, in slaughterhouse A, and pellets, in slaughterhouse B, used for heating water take the second place, with a mean contribution of about 45%. On average, a 62 kgoe/t specific energy consumption (SEC) was found, although with differences between slaughterhouses. A prominent negative correlation between SEC and carcass production was found specially in slaughterhouse A. Estimated Specific Energy Cost and Greenhouse Gases Intensity (GHGI) show mean values of about 50 €/t and 1.8 tCO2e/toe, respectively. Main results show that there is a significant margin for improving energy efficiency and therefore lowering costs in this type of non-energy intensive industries.