Abstract: Being made with the lightest commercially available industrial metal, Magnesium (Mg) alloys are of interest for light-weighting. Expanding their application to different material processing methods requires Mg properties at large strains. Several room-temperature processes such as shot and laser peening and hole cold expansion need compressive large strain data. Two methods have been proposed in the literature to obtain the stress-strain curve at high strains: 1) anti-buckling guides and 2) small cubic samples. In this paper, an anti-buckling fixture is used with the help of digital image correlation (DIC) to obtain the compression-tension (C-T) of AZ31B-H24 rolled sheet at large strain values of up to 10.5%. The effect of the anti-bucking fixture on stress-strain curves is evaluated experimentally by comparing the results with those of the compression tests of cubic samples. For testing cubic samples, a new fixture has been designed to increase the accuracy of testing cubic samples with DIC strain measurements. Results show a negligible effect of anti-buckling on stress-strain curves, specifically at high strain values.
Abstract: The purposes of hydraulic gate are to maintain the
functions of storing and draining water. It bears long-term hydraulic
pressure and earthquake force and is very important for reservoir and
waterpower plant. The high tensile strength of steel plate is used as
constructional material of hydraulic gate. The cracks and rusts,
induced by the defects of material, bad construction and seismic
excitation and under water respectively, thus, the mechanics
phenomena of gate with crack are probing into the cause of stress
concentration, induced high crack increase rate, affect the safety and
usage of hydroelectric power plant. Stress distribution analysis is a
very important and essential surveying technique to analyze
bi-material and singular point problems. The finite difference
infinitely small element method has been demonstrated, suitable for
analyzing the buckling phenomena of welding seam and steel plate
with crack. Especially, this method can easily analyze the singularity
of kink crack. Nevertheless, the construction form and deformation
shape of some gates are three-dimensional system. Therefore, the
three-dimensional Digital Image Correlation (DIC) has been
developed and applied to analyze the strain variation of steel plate with
crack at weld joint. The proposed Digital image correlation (DIC)
technique is an only non-contact method for measuring the variation of
test object. According to rapid development of digital camera, the cost
of this digital image correlation technique has been reduced.
Otherwise, this DIC method provides with the advantages of widely
practical application of indoor test and field test without the restriction
on the size of test object. Thus, the research purpose of this research is
to develop and apply this technique to monitor mechanics crack
variations of weld steel hydraulic gate and its conformation under
action of loading. The imagines can be picked from real time
monitoring process to analyze the strain change of each loading stage.
The proposed 3-Dimensional digital image correlation method,
developed in the study, is applied to analyze the post-buckling
phenomenon and buckling tendency of welded steel plate with crack.
Then, the stress intensity of 3-dimensional analysis of different
materials and enhanced materials in steel plate has been analyzed in
this paper. The test results show that this proposed three-dimensional
DIC method can precisely detect the crack variation of welded steel
plate under different loading stages. Especially, this proposed DIC
method can detect and identify the crack position and the other flaws
of the welded steel plate that the traditional test methods hardly detect
these kind phenomena. Therefore, this proposed three-dimensional
DIC method can apply to observe the mechanics phenomena of
composite materials subjected to loading and operating.
Abstract: In the past decade, the use of digital image correlation
(DIC) techniques has increased significantly in the area of
experimental mechanics, especially for materials behavior
characterization. This non-contact tool enables full field displacement
and strain measurements over a complete region of interest. The DIC
algorithm requires a random contrast pattern on the surface of the
specimen in order to perform properly. To create this pattern, the
specimen is usually first coated using a white matt paint. Next, a
black random speckle pattern is applied using any suitable method. If
the applied paint coating is too thick, its top surface may not be able
to exactly follow the deformation of the specimen, and consequently,
the strain measurement might be underestimated. In the present
article, a study of the influence of the paint thickness on the strain
underestimation is performed for different strain levels. The results
are then compared to typical paint coating thicknesses applied by
experienced DIC users. A slight strain underestimation was observed
for paint coatings thicker than about 30μm. On the other hand, this
value was found to be uncommonly high compared to coating
thicknesses applied by DIC users.
Abstract: All current experimental methods for determination of
stress intensity factors are based on the assumption that the state of
stress near the crack tip is plane stress. Therefore, these methods rely
on strain and displacement measurements made outside the near
crack tip region affected by the three-dimensional effects or by
process zone. In this paper, we develop and validate an experimental
procedure for the evaluation of stress intensity factors from the
measurements of the out-of-plane displacements in the surface area
controlled by 3D effects. The evaluation of stress intensity factors is
possible when the process zone is sufficiently small, and the
displacement field generated by the 3D effects is fully encapsulated
by K-dominance region.
Abstract: Over the past four decades, the fatigue behavior of
nickel-based alloys has been widely studied. However, in recent
years, significant advances in the fabrication process leading to grain
size reduction have been made in order to improve fatigue properties
of aircraft turbine discs. Indeed, a change in particle size affects the
initiation mode of fatigue cracks as well as the fatigue life of the
material. The present study aims to investigate the fatigue behavior of
a newly developed nickel-based superalloy under biaxial-planar
loading. Low Cycle Fatigue (LCF) tests are performed at different
stress ratios so as to study the influence of the multiaxial stress state
on the fatigue life of the material. Full-field displacement and strain
measurements as well as crack initiation detection are obtained using
Digital Image Correlation (DIC) techniques. The aim of this
presentation is first to provide an in-depth description of both the
experimental set-up and protocol: the multiaxial testing machine, the
specific design of the cruciform specimen and performances of the
DIC code are introduced. Second, results for sixteen specimens
related to different load ratios are presented. Crack detection, strain
amplitude and number of cycles to crack initiation vs. triaxial stress
ratio for each loading case are given. Third, from fractographic
investigations by scanning electron microscopy it is found that the
mechanism of fatigue crack initiation does not depend on the triaxial
stress ratio and that most fatigue cracks initiate from subsurface
carbides.
Abstract: Digital image correlation (DIC) is a contactless fullfield
displacement and strain reconstruction technique commonly
used in the field of experimental mechanics. Comparing with
physical measuring devices, such as strain gauges, which only
provide very restricted coverage and are expensive to deploy widely,
the DIC technique provides the result with full-field coverage and
relative high accuracy using an inexpensive and simple experimental
setup. It is very important to study the natural patterns effect on the
DIC technique because the preparation of the artificial patterns is
time consuming and hectic process. The objective of this research is
to study the effect of using images having natural pattern on the
performance of DIC. A systematical simulation method is used to
build simulated deformed images used in DIC. A parameter (subset
size) used in DIC can have an effect on the processing and accuracy
of DIC and even cause DIC to failure. Regarding to the picture
parameters (correlation coefficient), the higher similarity of two
subset can lead the DIC process to fail and make the result more
inaccurate. The pictures with good and bad quality for DIC methods
have been presented and more importantly, it is a systematic way to
evaluate the quality of the picture with natural patterns before they
install the measurement devices.
Abstract: Vacuum assisted resin transfer moulding (VARTM) is a promising manufacture process for making large and complex fiber reinforced composite structures. However, the complexity of the flow of the resin in the infusion stage usually leads to nonuniform property distribution of the produced composite part. In order to control the flow of the resin, the situation of flow should be mastered. For the safety of the usage of the produced composite in practice, the understanding of the property distribution is essential. In this paper, we did some trials on monitoring the resin infusion stage and evaluation for the fiber volume fraction distribution of the VARTM produced composite using the digital image correlation methods. The results showthat3D-DIC is valid on monitoring the resin infusion stage and it is possible to use 2D-DIC to estimate the distribution of the fiber volume fraction on a FRP plate.
Abstract: Displacement measurement was conducted on compact normal and shear specimens made of acrylic homogeneous material subjected to mixed-mode loading by digital image correlation. The intelligent hybrid method proposed by Nishioka et al. was applied to the stress-strain analysis near the crack tip. The accuracy of stress-intensity factor at the free surface was discussed from the viewpoint of both the experiment and 3-D finite element analysis. The surface images before and after deformation were taken by a CMOS camera, and we developed the system which enabled the real time stress analysis based on digital image correlation and inverse problem analysis. The great portion of processing time of this system was spent on displacement analysis. Then, we tried improvement in speed of this portion. In the case of cracked body, it is also possible to evaluate fracture mechanics parameters such as the J integral, the strain energy release rate, and the stress-intensity factor of mixed-mode. The 9-points elliptic paraboloid approximation could not analyze the displacement of submicron order with high accuracy. The analysis accuracy of displacement was improved considerably by introducing the Newton-Raphson method in consideration of deformation of a subset. The stress-intensity factor was evaluated with high accuracy of less than 1% of the error.
Abstract: Mechanical interaction between endothelial cells (ECs) and the extracellular matrix (or collagen gel) is known to influence the sprouting response of endothelial cells during angiogenesis. This influence is believed to impact on the capability of endothelial cells to sense soluble chemical cues. Quantitative analysis of endothelial-cell-mediated displacement of the collagen gel provides a means to explore this mechanical interaction. Existing analysis in this context is generally limited to 2D settings. In this paper, we investigate the mechanical interaction between endothelial cells and the extracellular matrix in terms of the endothelial-cellmediated displacement of the collagen gel in both 2D and 3D. Digital image correlation and Digital volume correlation are applied on confocal reflectance image stacks to analyze cell-mediated displacement of the gel. The skeleton of the sprout is extracted from phase contrast images and superimposed on the displacement field to further investigate the link between the development of the sprout and the displacement of the gel.
Abstract: Coronary artery bypass grafts (CABG) are widely
studied with respect to hemodynamic conditions which play
important role in presence of a restenosis. However, papers which
concern with constitutive modeling of CABG are lacking in the
literature. The purpose of this study is to find a constitutive model for
CABG tissue. A sample of the CABG obtained within an autopsy
underwent an inflation–extension test. Displacements were
recoredered by CCD cameras and subsequently evaluated by digital
image correlation. Pressure – radius and axial force – elongation
data were used to fit material model. The tissue was modeled as onelayered
composite reinforced by two families of helical fibers. The
material is assumed to be locally orthotropic, nonlinear,
incompressible and hyperelastic. Material parameters are estimated
for two strain energy functions (SEF). The first is classical
exponential. The second SEF is logarithmic which allows
interpretation by means of limiting (finite) strain extensibility.
Presented material parameters are estimated by optimization based
on radial and axial equilibrium equation in a thick-walled tube. Both
material models fit experimental data successfully. The exponential
model fits significantly better relationship between axial force and
axial strain than logarithmic one.