Abstract: Multifamily residential buildings are increasingly being built with large glazed areas to provide tenants with greater daylight and outdoor views. However, traditional double-glazed window assemblies can lead to significant thermal discomfort from high radiant temperatures as well as increased cooling energy use to address solar gains. Dynamic glazing provides an effective solution by actively controlling solar transmission to maintain indoor thermal comfort, without compromising the visual connection to outdoors. This study uses thermal simulations across three Canadian cities (Toronto, Vancouver and Montreal) to verify if dynamic glazing along with operable windows and ceiling fans can maintain the indoor operative temperature of a prototype southwest facing high-rise apartment unit within the ASHRAE 55 adaptive comfort range for a majority of the year, without any mechanical cooling. Since this study proposes the use of natural ventilation for cooling and the typical building life cycle is 30-40 years, the typical weather files have been modified based on accepted global warming projections for increased air temperatures by 2050. Results for the prototype apartment confirm that thermal discomfort with dynamic glazing occurs only for less than 0.7% of the year. However, in the baseline scenario with low-E glass there are up to 7% annual hours of discomfort despite natural ventilation with operable windows and improved air movement with ceiling fans.
Abstract: This study presents the use of daylight in the case study of the Reid building at the Glasgow School of Art in the city of Glasgow, UK. In Nordic countries, daylight is one of the main considerations within building design, especially in the face of long, lightless winters. A shortage of daylight, contributing to dark and gloomy conditions, necessitates that designs incorporate strong daylight performance. As such, the building in question is designed to capture natural light for varying needs, where studios are located on the North and South façades. The study’s approach presents an analysis of different façade scenarios, where daylight from the North is observed, analyzed and compared with the daylight from the South façade for various design studios in the building. The findings then are correlated with the results of daylight levels from the daylight simulation program (Autodesk Ecotect Analysis) for the investigated studios. The study finds there to be a dramatic difference in daylight nature and levels between the North and South façades, where orientation, obstructions and designed façade fenestrations have major effects on the findings. The study concludes that some of the studios positioned on the North façade do not have a desirable quality of diffused northern light, due to the outside building’s obstructions, area and volume of the studio and the shadow effect of the designed mezzanine floor in the studios.
Abstract: As the development of information and communication technology, the convergence of machine learning of the ICT area and design is attempted. In this way, it is possible to grasp the correlation between various design elements, which was difficult to grasp, and to reflect this in the design result. In architecture, there is an attempt to predict the performance, which is difficult to grasp in the past, by finding the correlation among multiple factors mainly through machine learning. In architectural design area, some attempts to predict the performance affected by various factors have been tried. With machine learning, it is possible to quickly predict performance. The aim of this study is to propose a model that predicts performance according to the block arrangement of apartment housing through machine learning and the design alternative which satisfies the performance such as the daylight hours in the most similar form to the alternative proposed by the designer. Through this study, a designer can proceed with the design considering various design alternatives and accurate performances quickly from the early design stage.
Abstract: Daylight utilization is a key factor in achieving visual and thermal comfort, and energy savings in integrated building design. However, lack of measured data related to this topic has become a major challenge with the increasing need for integrating lighting concepts and simulations in the early stages of design procedures. The current paper deals with the values of daylight illuminance on horizontal and south facing vertical surfaces; the data are estimated using IESNA model and measured values of the horizontal and vertical illuminance, and a regression model with an acceptable linear correlation is obtained. The resultant illuminance frequency curves are useful for estimating daylight availability on south facing surfaces in Tehran. In addition, the relationship between indirect vertical illuminance and the corresponding global horizontal illuminance is analyzed. A simple parametric equation is proposed in order to predict the vertical illumination on a shaded south facing surface. The equation correlates the ratio between the vertical and horizontal illuminance to the solar altitude and is used with another relationship for prediction of the vertical illuminance. Both equations show good agreement, which allows for calculation of indirect vertical illuminance on a south facing surface at any time throughout the year.
Abstract: The greatest influence we have from the world is shaped through the visual form, thus light is an inseparable element in human life. The use of daylight in visual perception and environment readability is an important issue for users. With regard to the hazards of greenhouse gas emissions from fossil fuels, and in line with the attitudes on the reduction of energy consumption, the correct use of daylight results in lower levels of energy consumed by artificial lighting, heating and cooling systems. Windows are usually the starting points for analysis and simulations to achieve visual comfort and energy optimization; therefore, attention should be paid to the orientation of buildings to minimize electrical energy and maximize the use of daylight. In this paper, by using the Design Builder Software, the effect of the orientation of an 18m2(3m*6m) room with 3m height in city of Tehran has been investigated considering the design constraint limitations. In these simulations, the dimensions of the building have been changed with one degree and the window is located on the smaller face (3m*3m) of the building with 80% ratio. The results indicate that the orientation of building has a lot to do with energy efficiency to meet high-performance architecture and planning goals and objectives.
Abstract: Architects commonly attempt a depiction of organic forms when their works are inspired by nature, regardless of the building site. Nevertheless it is also possible to try matching structures with natural scenery, by applying a phenomenological approach in terms of spatial operations, regarding perceptions from nature through architectural aspects such as protection, views, and orientation. This method acknowledges a relationship between place and space, where intentions towards tangible facts then become design statements. Although spaces resulting from such a process may present an effective response to the environment, they can also offer further outcomes beyond the realm of form. The hypothesis is that, in addition to recognising a bond between architecture and nature, it is also plausible to associate such perceptions with the inner ambient of buildings, by analysing features such as daylight. The case study of a single-family house in a rainforest near Valdivia, Chilean Patagonia is presented, with the intention of addressing the above notions through a discussion of the actual effects of inhabiting a place by way of a series of insights, including a revision of diagrams and photographs that assist in understanding the implications of this design practice. In addition, figures based on post-occupancy behaviour and daylighting performance relate both architectural and environmental issues to a decision-making process motivated by the observation of nature.
Abstract: To provide an efficient solar generation system, the embodiment design of a two axis solar tracker for an array of photovoltaic (PV) panels destiny to supply the power demand on off-the-grid areas was developed. Photovoltaic cells have high costs in relation to t low efficiency; and while a lot of research and investment has been made to increases its efficiency a few points, there is a profitable solution that increases by 30-40% the annual power production: two axis solar trackers. A solar tracker is a device that supports a load in a perpendicular position toward the sun during daylight. Mounted on solar trackers, the solar panels remain perpendicular to the incoming sunlight at day and seasons so the maximum amount of energy is outputted. Through a preview research done it was justified why the generation of solar energy through photovoltaic panels mounted on dual axis structures is an attractive solution to bring electricity to remote off-the-grid areas. The work results are the embodiment design of an azimuth-altitude solar tracker to guide an array of photovoltaic panels based on a specific design methodology. The designed solar tracker is mounted on a pedestal that uses two slewing drives‚ with a nominal torque of 1950 Nm‚ to move a solar array that provides 3720 W from 12 PV panels.
Abstract: In this paper, an attempt has been made to analyze the effect of wall window orientation on Daylight Illuminance Ratio (DIR) and energy saving in a building known as “SODHA BERS COMPLEX (SBC)” at Varanasi, UP, India. The building has been designed incorporating all passive concepts for thermal comfort as well daylighting concepts to maximize the use of natural daylighting for the occupants in the day to day activities. The annual average DIR and the energy saving has been estimated by using the DIR model for wall window with different orientations under clear sky condition. It has been found that for south oriented window the energy saving per square meter is more compared to the other orientations due to the higher level of solar insolation for the south window in northern hemisphere whereas energy saving potential is minimum for north oriented wall window. The energy saving potential was 26%, 81% and 51% higher for east, south and west oriented window in comparison to north oriented window. The average annual DIR has same trends of variation as the annual energy saving and it is maximum for south oriented window and minimum for north oriented window.
Abstract: Result from the constant dwindle in natural resources,
the alternative way to reduce the costs in our daily life would be urgent
to be found in the near future. As the ancient technique based on the
theory of solar chimney since roman times, the double-skin façade are
simply composed of two large glass panels in purpose of daylighting
and also natural ventilation in the daytime. Double-skin façade is
generally installed on the exterior side of buildings as function as the
window, so there is always a huge amount of passive solar energy the
façade would receive to induce the airflow every sunny day. Therefore,
this article imposes a domestic double-skin window for residential
usage and attempts to improve the volume flow rate inside the cavity
between the panels by the frame geometry design, the installation of
outlet guide plate and the solar energy collection system. Note that the
numerical analyses are applied to investigate the characteristics of flow
field, and the boundary conditions in the simulation are totally based
on the practical experiment of the original prototype. Then we
redesign the prototype from the knowledge of the numerical results
and fluid dynamic theory, and later the experiments of modified
prototype will be conducted to verify the simulation results. The
velocities at the inlet of each case are increase by 5%, 45% and 15%
from the experimental data, and also the numerical simulation results
reported 20% improvement in volume flow rate both for the frame
geometry design and installation of outlet guide plate.
Abstract: This paper presents the results of a study on the
influence of varying percentages of rock bridges along a basal surface
defining a biplanar failure mode. A pseudo-coupled-hydromechanical
brittle fracture analysis is adopted using the state-of-the-art code
Slope Model. Model results show that rock bridge failure is strongly
influenced by the incorporation of groundwater pressures. The
models show that groundwater pressure can promote total failure of a
5% rock bridge along the basal surface. Once the percentage of the
rock bridges increases to 10 and 15%, although, the rock bridges are
broken, full interconnection of the surface defining the basal surface
of the biplanar mode does not occur. Increased damage is caused
when the rock bridge is located at the daylighting end of the basal
surface in proximity to the blast damage zone. As expected, some
cracking damage is experienced in the blast damage zone, where
properties representing a good quality controlled damage blast
technique were assumed. Model results indicate the potential increase
of permeability towards the blast damage zone.
Abstract: This paper addresses the design of hospital Intensive
Care Unit windows for the achievement of visual comfort and energy
savings. The aim was to identify the window size and shading system
configurations that could fulfill daylighting adequacy, avoid glare
and reduce energy consumption. The study focused on addressing the
effect of utilizing different shading systems in association with a
range of Window-to-Wall Ratios (WWR) in different orientations
under the desert clear-sky of Cairo, Egypt.
The results of this study demonstrated that solar penetration is a
critical concern affecting the design of ICU windows in desert
locations, as in Cairo, Egypt. Use of shading systems was found to be
essential in providing acceptable daylight performance and energy
saving. Careful positioning of the ICU window towards a proper
orientation can dramatically improve performance. It was observed
that ICU windows facing the north direction enjoyed the widest range
of successful window configuration possibilities at different WWRs.
ICU windows facing south enjoyed a reasonable number of
configuration options as well. By contrast, the ICU windows facing
the east orientation had a very limited number of options that provide
acceptable performance. These require additional local shading
measures at certain times due to glare incidence. Moreover, use of
horizontal sun breakers and solar screens to protect the ICU windows
proved to be more successful than the other alternatives in a wide
range of Window to Wall Ratios. By contrast, the use of light shelves
and vertical shading devices seemed questionable.
Abstract: This research focuses on the optimization of glazed
surfaces and the assessment of possible solar gains in industrial
buildings. Existing window rating methods for single windows were
evaluated and a new method for a simple analysis of energy gains and
losses by single windows was introduced. Furthermore extensive
transient building simulations were carried out to appraise the
performance of low cost polycarbonate multi-cell sheets in
interaction with typical buildings for industrial applications. Mainly
energy saving potential was determined by optimizing the orientation
and area of such glazing systems in dependency on their thermal
qualities. Moreover the impact on critical aspects such as summer
overheating and daylight illumination was considered to ensure the
user comfort and avoid additional energy demand for lighting or
cooling. Hereby the simulated heating demand could be reduced by
up to 1/3 compared to traditional architecture of industrial halls using
mainly skylights.
Abstract: Hospitals, everywhere, are considered heavy energy consumers. Hospital Intensive Care Unit spaces pose a special challenge, where design guidelines requires the provision of external windows for daylighting and external view. Window protection strategies could be employed to reduce energy loads without detriment effect on comfort or health care. This paper addresses the effectiveness of using various window strategies on the annual cooling, heating and lighting energy use of a typical Hospital Intensive Unit space. Series of experiments were performed using the EnergyPlus simulation software for a typical Intensive Care Unit (ICU) space in Cairo, located in the Egyptian desert. This study concluded that the use of shading systems is more effective in conserving energy in comparison with glazing of different types, in the Cairo ICUs. The highest energy savings in the West and South orientations were accomplished by external perforated solar screens, followed by overhangs positioned at a protection angle of 45°.
Abstract: Careful design and selection of daylighting systems can greatly help in reducing not only artificial lighting use, but also decrease cooling energy consumption and, therefore, potential for downsizing air-conditioning systems. This paper aims to evaluate the energy performance of two types of top-light daylighting systems due to the integration of daylight together with artificial lighting in an existing examinaton hall in University Kebangsaan Malaysia, based on a hot and humid climate. Computer simulation models have been created for building case study (base case) and the two types of toplight daylighting designs for building energy performance evaluation using the VisualDOE 4.0 building energy simulation program. The finding revealed that daylighting through top-light systems is a very beneficial design strategy in reducing annual lighting energy consumption and the overall total annual energy consumption.
Abstract: The construction of a civil structure inside a urban
area inevitably modifies the outdoor microclimate at the building
site. Wind speed, wind direction, air pollution, driving rain, radiation
and daylight are some of the main physical aspects that are subjected
to the major changes. The quantitative amount of these modifications
depends on the shape, size and orientation of the building and on its
interaction with the surrounding environment.The flow field over a
flat roof model building has been numerically investigated in order to
determine two-dimensional CFD guidelines for the calculation of the
turbulent flow over a structure immersed in an atmospheric boundary
layer. To this purpose, a complete validation campaign has been
performed through a systematic comparison of numerical simulations
with wind tunnel experimental data.Several turbulence models and
spatial node distributions have been tested for five different vertical
positions, respectively from the upstream leading edge to the
downstream bottom edge of the analyzed model. Flow field
characteristics in the neighborhood of the building model have been
numerically investigated, allowing a quantification of the capabilities
of the CFD code to predict the flow separation and the extension of
the recirculation regions.The proposed calculations have allowed the
development of a preliminary procedure to be used as a guidance in
selecting the appropriate grid configuration and corresponding
turbulence model for the prediction of the flow field over a twodimensional
roof architecture dominated by flow separation.
Abstract: In the Northern hemisphere, sheep reproduction is
seasonal (September-November). Among several natural factors
influencing the reproduction status of rams, we studied the daylight
length and temperature. Rams from different breeds were studied:
Merinos de Palas (half-precocious), Karakul de Botosani (halfbelated)
and Turcana (belated breed, low reproductive plasticity). In
Merinos de Palas, ejaculate volume during sexual repose is 51.3%
from normal quantity. When autumn climate was experimentally
induced, ejaculate volume reached 98.45% (Merinos), 94.97%
(Karakul) and 97.59% (Turcana). Semen density increased from
1.031-1.033 till 1.035 after exposition to artificial light and
temperature conditions. Spermatozoids mobility and sperm pH
improved, passing over 82% and 6.75, values identical to those in the
natural reproduction season. Behaviour analysis after
photoperiodicity indicated that over 83.3% Merinos and Karakul
males and all Turcana rams exteriorised normal and intense sexual
reflexes. Certain effort and reduced expenses brought rams in good
condition, producing higher quantity and quality sperm.
Abstract: The renewable energy has been attracting attention as
a new alternative energy due to the problem of environmental
pollution and resource depletion. In particular, daylighting and PV
system are regarded as the solutions. In this paper, the hybrid
dimming control system supplied by solar cell and daylighting
system was designed. Daylighting system is main source and PV
system is spare source. PV system operates the LED lamp which
supports daylighting system because daylighting system is unstable
due to the variation of irradiance. In addition, PV system has a role
charging batteries. Battery charging has a benefit that PV system
operate LED lamp in the bad weather. However, LED lamp always
can`t turn on that-s why dimming control system was designed. In
particular, the solar charging robot was designed to check the
interior irradiance intensity. These systems and the application of
the solar charging robot are expected to contribute developing
alternative energy in the near future.
Abstract: Recent developments in automotive technology are focused on economy, comfort and safety. Vehicle tracking and collision detection systems are attracting attention of many investigators focused on safety of driving in the field of automotive mechatronics. In this paper, a vision-based vehicle detection system is presented. Developed system is intended to be used in collision detection and driver alert. The system uses RGB images captured by a camera in a car driven in the highway. Images captured by the moving camera are used to detect the moving vehicles in the image. A vehicle ahead of the camera is detected in daylight conditions. The proposed method detects moving vehicles by subtracting successive images. Plate height of the vehicle is determined by using a plate recognition algorithm. Distance of the moving object is calculated by using the plate height. After determination of the distance of the moving vehicle relative speed of the vehicle and Time-to-Collision are calculated by using distances measured in successive images. Results obtained in road tests are discussed in order to validate the use of the proposed method.
Abstract: A lightpipe is an about 99 percent specular reflective
mirror pipe or duct that is used for the transmission of the daylight
from the outside into a building. The lightpipes are usually used in
the daylighting buildings, in the residential, industrial and
commercial sectors. This paper is about the performances of a
lightpipe installed in a laboratory (3 m x 2.6 m x 3 m) without
windows. The aim is to analyse the luminous intensity distribution
for several sky/sun conditions. The lightpipe was monitored during
the year 2006. The lightpipe is 1 m long and the diameter of the top
collector and of the internal diffuser device is 0.25 m. In the
laboratory there are seven illuminance sensors: one external is
located on the roof of the laboratory and six internal sensors are
connected to a data acquisition system. The internal sensors are
positioned under the internal diffusive device at an height of 0.85 m
from the floor to simulate a working plane. The numerical data are
obtained through a simulation software. This paper shows the
comparison between the experimental and numerical results
concerning the behavior of the lightpipe.
Abstract: This paper investigated the impact of ceiling height and window head heights variation on daylighting inside architectural teaching studio with a full width window. In architectural education, using the studio is more than normal classroom in most credit hours. Therefore, window position, size and dimension of studio have direct influence on level of daylighting. Daylighting design is a critical factor that improves student learning, concentration and behavior, in addition to these, it also reduces energy consumption. The methodology of analysis involves using Radiance in IES software under overcast and cloudy sky in Malaysia. It has been established that presentation of daylighting of architecture studio can be enhanced by changing the ceiling heights and window level, because, different ceiling heights and window head heights can contribute to different range of daylight levels.