Development of Moving Multifocal Electroretinogram with a Precise Perimetry Apparatus

A decline in visual sensitivity at arbitrary points on the retina can be measured using a precise perimetry apparatus along with a fundus camera. However, the retinal layer associated with this decline cannot be identified accurately with current medical technology. To investigate cryptogenic diseases, such as macular dystrophy, acute zonal occult outer retinopathy (AZOOR), and multiple evanescent white dot syndrome (MEWDS), we evaluated an electroretinogram (ERG) function that allows moving the center of the multifocal hexagonal stimulus array to a chosen position. Macular dystrophy is a generalized term used for a variety of functional disorders of the macula lutea, and the ERG shows a diminution of the b-wave in these disorders. AZOOR causes an acute functional disorder to an outer layer of the retina, and the ERG shows a-wave and b-wave amplitude reduction as well as delayed 30 Hz flicker responses. MEWDS causes acute visual loss and the ERG shows a decrease in a-wave amplitude. We combined an electroretinographic optical system and a perimetric optical system into an experimental apparatus that has the same optical system as that of a fundus camera. We also deployed an EO-50231 Edmund infrared camera, a 45-degree cold mirror, a lens with a 25-mm focal length, a halogen lamp, and an 8-inch monitor. Then, we also employed a differential amplifier with gain 10, a 50 Hz notch filter, a high-pass filter with a 21.2 Hz cut-off frequency, and two non-inverting amplifiers with gains 1001 and 11. In addition, we used a USB-6216 National Instruments I/O device, a NE-113A Nihon Kohden plate electrode, a SCB-68A shielded connector block, and LabVIEW 2017 software for data retrieval. The software was used to generate the multifocal hexagonal stimulus array on the computer monitor with C++Builder 10.2 and to move the center of the array toward the left and right and up and down. Cone and bright flash ERG results were observed using the moving ERG function. The a-wave, b-wave, c-wave, and the photopic negative response were identified with cone ERG. The moving ERG function allowed the identification of the retinal layer causing visual alterations.

CookIT: A Web Portal for the Preservation and Dissemination of Traditional Italian Recipes

Food is a social and cultural aspect of every individual. Food products, processing, and traditions have been identified as cultural objects carrying history and identity of social groups. Traditional recipes are passed down from one generation to the other, often to strengthen the link with the territory. The paper presents CookIT, a web portal developed to collect Italian traditional recipes related to regional cuisine, with the purpose to disseminate the knowledge of typical Italian recipes and the Mediterranean diet which is a significant part of Italian cuisine. The system designed is completed with multimodal means of browsing and data retrieval. Stored recipes can be retrieved integrating and combining a number of different methods and keys, while the results are displayed using classical styles, such as list and mosaic, and also using maps and graphs, with which users can play using available keys for interaction.

Basic Research for Electroretinogram Moving the Center of the Multifocal Hexagonal Stimulus Array

Many ophthalmologists can examine declines in visual sensitivity at arbitrary points on the retina using a precise perimetry device with a fundus camera function. However, the retinal layer causing the decline in visual sensitivity cannot be identified by this method. We studied an electroretinogram (ERG) function that can move the center of the multifocal hexagonal stimulus array in order to investigate cryptogenic diseases, such as macular dystrophy, acute zonal occult outer retinopathy, and multiple evanescent white dot syndrome. An electroretinographic optical system, specifically a perimetric optical system, was added to an experimental device carrying the same optical system as a fundus camera. We also added an infrared camera, a cold mirror, a halogen lamp, and a monitor. The software was generated to show the multifocal hexagonal stimulus array on the monitor using C++Builder XE8 and to move the center of the array up and down as well as back and forth. We used a multifunction I/O device and its design platform LabVIEW for data retrieval. The plate electrodes were used to measure electrodermal activities around the eyes. We used a multifocal hexagonal stimulus array with 37 elements in the software. The center of the multifocal hexagonal stimulus array could be adjusted to the same position as the examination target of the precise perimetry. We successfully added the moving ERG function to the experimental ophthalmologic device.

Developing an Online Library for Faster Retrieval of Mold Base and Standard Parts of Injection Molding

This paper focuses on developing a system to transfer mold base plates and standard parts faster during the stage of injection mold design. This system not only provides a way to compare the file version, but also it utilizes Siemens NX 10 to isolate the updated information into a single executable file (.dll), and then, the file can be transferred without the need of transferring the whole file. By this way, the system can help the user to download only necessary mold base plates and standard parts, and those parts downloaded are only the updated portions.

A Feasibility-study of a Micro- Communications Sonobuoy Deployable by UAV Robots

This paper describes a feasibility study that is included with the research, development and testing of a micro communications sonobuoy deployable by Maritime Fixed wing Unmanned Aerial Vehicles (M-UAV) and rotor wing Quad Copters which are both currently being developed by the University of Adelaide. The micro communications sonobuoy is developed to act as a seamless communication relay between an Autonomous Underwater Vehicle (AUV) and an above water human operator some distance away. Development of such a device would eliminate the requirement of physical communication tethers attached to submersible vehicles for control and data retrieval.