Abstract: In context of understanding problems faced by undergraduate students while carrying out laboratory experiments dealing with high voltages, it was found that most of the students are hesitant to work directly on machine. The reason is that error in the circuitry might lead to deterioration of machine and laboratory instruments. So, it has become inevitable to include modern pedagogic techniques for undergraduate students, which would help them to first carry out experiment in virtual system and then to work on live circuit. Further advantages include that students can try out their intuitive ideas and perform in virtual environment, hence leading to new research and innovations. In this paper, virtual environment used is of MATLAB/Simulink for three-phase induction machines. The performance analysis of three-phase induction machine is carried out using virtual environment which includes Direct Current (DC) Test, No-Load Test, and Block Rotor Test along with speed torque characteristics for different rotor resistances and input voltage, respectively. Further, this paper carries out computer aided teaching of basic Voltage Source Inverter (VSI) drive circuitry. Hence, this paper gave undergraduates a clearer view of experiments performed on virtual machine (No-Load test, Block Rotor test and DC test, respectively). After successful implementation of basic tests, VSI circuitry is implemented, and related harmonic distortion (THD) and Fast Fourier Transform (FFT) of current and voltage waveform are studied.
Abstract: This paper presents a comparison between two Pulse
Width Modulation (PWM) algorithms applied to a three-level Neutral
Point Clamped (NPC) Voltage Source Inverter (VSI). The first
algorithm applied is the triangular-sinusoidal strategy; the second is
the Space Vector Pulse Width Modulation (SVPWM) strategy. In the
first part, we present a topology of three-level NCP VSI. After that,
we develop the two PWM strategies to control this converter. At the
end the experimental results are presented.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.