Abstract: Two finite element (FEM) models are presented in
this paper to address the random nature of the response of glued
timber structures made of wood segments with variable elastic
moduli evaluated from 3600 indentation measurements. This total
database served to create the same number of ensembles as was the
number of segments in the tested beam. Statistics of these ensembles
were then assigned to given segments of beams and the Latin
Hypercube Sampling (LHS) method was called to perform 100
simulations resulting into the ensemble of 100 deflections subjected
to statistical evaluation. Here, a detailed geometrical arrangement of
individual segments in the laminated beam was considered in the
construction of two-dimensional FEM model subjected to in fourpoint
bending to comply with the laboratory tests. Since laboratory
measurements of local elastic moduli may in general suffer from a
significant experimental error, it appears advantageous to exploit the
full scale measurements of timber beams, i.e. deflections, to improve
their prior distributions with the help of the Bayesian statistical
method. This, however, requires an efficient computational model
when simulating the laboratory tests numerically. To this end, a
simplified model based on Mindlin’s beam theory was established.
The improved posterior distributions show that the most significant
change of the Young’s modulus distribution takes place in laminae in
the most strained zones, i.e. in the top and bottom layers within the
beam center region. Posterior distributions of moduli of elasticity
were subsequently utilized in the 2D FEM model and compared with
the original simulations.
Abstract: The use OF adhesive anchors for wooden constructions is an efficient technology to connect and design timber members in new timber structures and to rehabilitate the damaged structural members of historical buildings. Due to the lack of standard regulation in this specific area of structural design, designers’ choices are still supported by test analysis that enables knowledge, and the prediction, of the structural behaviour of glued in rod joints. The paper outlines an experimental research activity aimed at identifying the tensile resistance capacity of several new adhesive joint prototypes made of epoxy resin, steel bar and timber, Oak and Douglas Fir species. The development of new adhesive connectors has been carried out by using epoxy to glue stainless steel bars into pre-drilled holes, characterised by smooth and rough internal surfaces, in timber samples. The realization of a threaded contact surface using a specific drill bit has led to an improved bond between wood and epoxy. The applied changes have also reduced the cost of the joints’ production. The paper presents the results of this parametric analysis and a Finite Element analysis that enables identification and study of the internal stress distribution in the proposed adhesive anchors.
Abstract: Cross-laminated timber is increasingly being used in
the construction of high-rise buildings due to its simple
manufacturing system. In term of fire resistance, cross-laminated
timber panels are promoted as having excellent fire resistance,
comparable to that of non-combustible materials and to heavy
timber construction, due to the ability of thick wood assemblies to
char slowly at a predictable rate while maintaining most of their
strength during the fire exposure. This paper presents an overview of
fire performance of cross-laminated timber and evaluation of its
resistance to elevated temperature in comparison to homogeneous
timber panels. Charring rates for cross-laminated timber panels of
those obtained experimentally were compared with those provided by
Eurocode simplified calculation methods.