Abstract: The present study is an attempt to demonstrate the significant levels of contribution of the moment-resisting beam-column connections with side plates to the earthquake behavior of special steel moment frames. To this end, the moment-curvature relationships of a regular beam-column connection and its SidePlate counterpart were determined with the help of finite element analyses. The connection stiffness and deformability values from these finite element analyses were used in the linear time-history analyses of an example structural steel frame under three different seismic excitations. The top-story lateral drift, base shear, and overturning moment values in two orthogonal directions were obtained from these time-history analyses and compared to each other. The results revealed the improvements in the system response with the use of SidePlate connections. The paper ends with crucial recommendations for the plan and design of further studies on this very topic.
Abstract: The seismic forces caused by the waves created in the depths of the earth during the earthquake hit the structure and cause the building to vibrate. Creating large seismic forces will cause low-strength sections in the structure to suffer extensive surface damage. The use of new steel shear walls in steel structures has caused the strength of the building and its main members (columns) to increase due to the reduction and depreciation of seismic forces during earthquakes. In the present study, an attempt was made to evaluate a type of steel shear wall that has regular holes in the inner sheet by modeling the finite element model with Abacus software. The shear wall of the steel plate, measuring 6000 × 3000 mm (one floor) and 3 mm thickness, was modeled with four different pores with a cross-sectional area. The shear wall was dynamically subjected to a time history of 5 seconds by three accelerators, El Centro, Imperial Valley and Kobe. The results showed that increasing the distance between the geometric center of the hole and the geometric center of the inner plate in the steel shear wall (increasing the RCS index) caused the total maximum acceleration to be transferred from the perimeter of the hole to horizontal and vertical beams. The results also show that there is no direct relationship between RCS index and total acceleration in steel shear wall and RCS index is separate from the peak ground acceleration value of earthquake.
Abstract: Due to the constant increase in terrorist attacks, the research and engineering communities have given significant attention to building performance under explosions. This paper presents a methodology for studying and simulating the dynamic responses of steel structures during external detonations, particularly for accurately investigating the impact of incrementing charge weight on the members total behavior, resistance and failure. Prediction damage method was introduced to evaluate the damage level of the steel members based on five scenarios of explosions. Johnson–Cook strength and failure model have been used as well as ABAQUS finite element code to simulate the explicit dynamic analysis, and antecedent field tests were used to verify the acceptance and accuracy of the proposed material strength and failure model. Based on the structural response, evaluation criteria such as deflection, vertical displacement, drift index, and damage level; the obtained results show the vulnerability of steel columns and un-braced steel frames which are designed and optimized to carry dead and live load to resist and endure blast loading.
Abstract: Recent ground motion records demonstrate that the near-field earthquakes have various properties compared to far-field earthquakes. In general, most of these properties are affected by an important phenomenon called ‘forward directivity’ in near-fault earthquakes. Measuring structural damages are one of the common activities administered after an earthquake. Predicting the amount of damage caused by the earthquake as well as determining the vulnerability of the structure is extremely significant. In order to measure the amount of structural damages, instead of calculating the acceleration and velocity spectrum, it is possible to use the damage spectra of the structure. The damage spectrum is a kind of nonlinear spectrum that is drawn by setting the nonlinear parameters related to the single degree of freedom structures and its dynamic analysis under the specific record and measuring damage of any structure. In this study, the damage spectra of steel structures have been drawn. For this purpose, different kinds of concentric and eccentric braced structures with various ductility coefficients in hard and soft soil under near-field and far-field ground motion records have been considered using the Krawinkler and Zohrei damage index. The results indicate that, by increasing the structures' fundamental period, the amount of damage increases under the near-field earthquakes compared to far-field earthquakes. In addition, by increasing the structure ductility, the amount of damage based on near-field and far-field earthquakes decreases noticeably. Furthermore, in concentric braced structures, the amount of damage under the near-field earthquakes is almost two times more than the amount of damage in eccentrically braced structures especially for fundamental periods larger than 0.6 s.
Abstract: This paper presents a ground structure method to optimize the topology and discrete member sizing of steel frame structures in order to minimize total installed cost, including material, fabrication and erection components. The proposed method improves upon existing cost-based ground structure methods by incorporating constructability considerations well as satisfying both strength and serviceability constraints. The architecture for the method is a bi-level Multidisciplinary Feasible (MDF) architecture in which the discrete member sizing optimization is nested within the topology optimization process. For each structural topology generated, the sizing optimization process seek to find a set of discrete member sizes that result in the lowest total installed cost while satisfying strength (member utilization) and serviceability (node deflection and story drift) criteria. To accurately assess cost, the connection details for the structure are generated automatically using accurate site-specific cost information obtained directly from fabricators and erectors. Member continuity rules are also applied to each node in the structure to improve constructability. The proposed optimization method is benchmarked against conventional weight-based ground structure optimization methods resulting in an average cost savings of up to 30% with comparable computational efficiency.
Abstract: The review of selected methods of strengthening of steel structures with carbon fiber reinforced polymer (CFRP) tapes and the analysis of influence of composite materials on the steel thin-walled elements are performed in this paper. The study is also focused to the problem of applying fast and effective strengthening methods of the steel structures made of thin-walled profiles. It is worth noting that the issue of strengthening the thin-walled structures is a very complex, due to inability to perform welded joints in this type of elements and the limited ability to applying mechanical fasteners. Moreover, structures made of thin-walled cross-section demonstrate a high sensitivity to imperfections and tendency to interactive buckling, which may substantially contribute to the reduction of critical load capacity. Due to the lack of commonly used and recognized modern methods of strengthening of thin-walled steel structures, authors performed the experimental studies of thin-walled sigma profiles strengthened with CFRP tapes. The paper presents the experimental stand and the preliminary results of laboratory test concerning the analysis of the effectiveness of the strengthening steel beams made of thin-walled sigma profiles with CFRP tapes. The study includes six beams made of the cold-rolled sigma profiles with height of 140 mm, wall thickness of 2.5 mm, and a length of 3 m, subjected to the uniformly distributed load. Four beams have been strengthened with carbon fiber tape Sika CarboDur S, while the other two were tested without strengthening to obtain reference results. Based on the obtained results, the evaluation of the accuracy of applied composite materials for strengthening of thin-walled structures was performed.
Abstract: The method selected for the design of structures not only can affect their seismic vulnerability but also can affect their construction cost. For the design of steel structures, two distinct methods have been introduced by existing codes, namely allowable stress design (ASD) and load resistant factor design (LRFD). This study investigates the effect of using the aforementioned design methods on the seismic vulnerability and construction cost of steel structures. Specifically, a 20-story building equipped with special moment resisting frame and an eccentrically braced system was selected for this study. The building was designed for three different intensities of peak ground acceleration including 0.2 g, 0.25 g, and 0.3 g using the ASD and LRFD methods. The required sizes of beams, columns, and braces were obtained using response spectrum analysis. Then, the designed frames were subjected to nine natural earthquake records which were scaled to the designed response spectrum. For each frame, the base shear, story shears, and inter-story drifts were calculated and then were compared. Results indicated that the LRFD method led to a more economical design for the frames. In addition, the LRFD method resulted in lower base shears and larger inter-story drifts when compared with the ASD method. It was concluded that the application of the LRFD method not only reduced the weights of structural elements but also provided a higher safety margin against seismic actions when compared with the ASD method.
Abstract: Shear walls made of cold formed steel are used as lateral force resisting components in residential and low-rise commercial and industrial constructions. The seismic design analysis of such structures is often complex due to the slenderness of members and their instability prevalence. In this context, a simplified modeling technique across the panel is proposed by using the finite element method. The approach is based on idealizing the whole panel by a nonlinear shear link element which reflects its shear behavior connected to rigid body elements which transmit the forces to the end elements (studs) that resist the tension and the compression. The numerical model of the shear wall panel was subjected to cyclic loads in order to evaluate the seismic performance of the structure in terms of lateral displacement and energy dissipation capacity. In order to validate this model, the numerical results were compared with those from literature tests. This modeling technique is particularly useful for the design of cold formed steel structures where the shear forces in each panel and the axial forces in the studs can be obtained using spectrum analysis.
Abstract: Web-expanded steel beams provide an easy and economical solution for the systems having longer structural members. The main goal of manufacturing these beams is to increase the moment of inertia and section modulus, which results in greater strength and rigidity. Until recently, there were two common types of open web-expanded beams: with hexagonal openings, also called castellated beams, and beams with circular openings referred to as cellular beams, until the generation of sinusoidal web-expanded beams. In the present research, the optimum design of a new generation beams, namely sinusoidal web-expanded beams, will be carried out and the design results will be compared with castellated and cellular beam solutions. Thanks to a reduced fabrication process and substantial material savings, the web-expanded beam with sinusoidal holes (Angelina™ Beam) meets the economic requirements of steel design problems while ensuring optimum safety. The objective of this research is to carry out non-linear finite element analysis (FEA) of the web-expanded beam with sinusoidal holes. The FE method has been used to predict their entire response to increasing values of external loading until they lose their load carrying capacity. FE model of each specimen that is utilized in the experimental studies is carried out. These models are used to simulate the experimental work to verify of test results and to investigate the non-linear behavior of failure modes such as web-post buckling, shear buckling and vierendeel bending of beams.
Abstract: Time history seismic analysis is supposed to be the most accurate method to predict the seismic demand of structures. On the other hand, the required computational time of this method toward achieving the result is its main deficiency. While being applied in optimization process, in which the structure must be analyzed thousands of time, reducing the required computational time of seismic analysis of structures makes the optimization algorithms more practical. Apparently, the invented approximate methods produce some amount of errors in comparison with exact time history analysis but the recently proposed method namely, Complete Quadratic Combination (CQC) and Sum Root of the Sum of Squares (SRSS) drastically reduces the computational time by combination of peak responses in each mode. In the present research, the Basic Modal Displacement (BMD) method is introduced and applied towards estimation of seismic demand of main structure. Seismic demand of sampled structure is estimated by calculation of modal displacement of basic structure (in which the modal displacement has been calculated). Shear steel sampled structures are selected as case studies. The error applying the introduced method is calculated by comparison of the estimated seismic demands with exact time history dynamic analysis. The efficiency of the proposed method is demonstrated by application of three types of earthquakes (in view of time of peak ground acceleration).
Abstract: This paper covers application of an elitist selfadaptive
step-size search (ESASS) to optimum design of steel
skeletal structures. In the ESASS two approaches are considered for
improving the convergence accuracy as well as the computational
efficiency of the original technique namely the so called selfadaptive
step-size search (SASS). Firstly, an additional randomness
is incorporated into the sampling step of the technique to preserve
exploration capability of the algorithm during the optimization.
Moreover, an adaptive sampling scheme is introduced to improve the
quality of final solutions. Secondly, computational efficiency of the
technique is accelerated via avoiding unnecessary analyses during the
optimization process using an upper bound strategy. The numerical
results demonstrate the usefulness of the ESASS in the sizing
optimization problems of steel truss and frame structures.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear
dynamics analysis of the structures with assuming elastic-perfectlyplastic
behavior was performed using RAM PERFORM-3D software;
the horizontal component was taken into consideration with and
without the incorporation of the corresponding vertical component.
Dynamic responses obtained for the horizontal component acting
alone were compared with those obtained from the simultaneous
application of both seismic components. The results show that the
effect of the vertical component of ground motion may increase the
axial load significantly in the interior columns and, consequently, the
stories. The plastic mechanisms would be changed. The P-Delta
effect is expected to increase. The punching base plate shear of the
columns should be considered. Moreover, the vertical component
increases the input energy when the structures exhibit inelastic
behavior and are taller.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear dynamics
analysis of the structures with assuming elastic-perfectly-plastic
behavior was performed using RAM PERFORM-3D software; the
horizontal component was taken into consideration with and without
the incorporation of the corresponding vertical component. Dynamic
responses obtained for the horizontal component acting alone were
compared with those obtained from the simultaneous application of
both seismic components. The results show that the effect of the
vertical component of ground motion may increase the axial load
significantly in the interior columns and, consequently, the stories.
The plastic mechanisms would be changed. The P-Delta effect is
expected to increase. The punching base plate shear of the columns
should be considered. Moreover, the vertical component increases the
input energy when the structures exhibit inelastic behavior and are
taller.
Abstract: Structure-borne noise is an important aspect of
offshore platform sound field. It can be generated either directly by
vibrating machineries induced mechanical force, indirectly by the
excitation of structure or excitation by incident airborne noise.
Therefore, limiting of the transmission of vibration energy
throughout the offshore platform is the key to control the structureborne
noise. This is usually done by introducing damping treatment
to the steel structures. Two types of damping treatment using onboard
are presented. By conducting a Statistical Energy Analysis
(SEA) simulation on a jack-up rig, the noise level in the source room,
the neighboring rooms, and remote living quarter cabins are
compared before and after the damping treatments been applied. The
results demonstrated that, in the source neighboring room and living
quarter area, there is a significant noise reduction with the damping
treatment applied, whereas in the source room where air-borne sound
predominates that of structure-borne sound, the impact is not
obvious. The conclusion on effective damping treatment in the
offshore platform is made which enable acoustic professionals to
implement noise control during the design stage for offshore crews’
hearing protection and habitant comfortability.
Abstract: The paper deals with the diagnostics of steel roof
structure of the winter sports halls built in 1970 year. The necessity
of the diagnostics has been given by the requirement to the evaluation
design of this structure, which has been caused by the new situation
in the field of the loadings given by the validity of the European
Standards in the Czech Republic from 2010 year. Due to these
changes in the normative rules, in practice existing structures are
gradually subjected to the evaluation design and depending on its
results to the strengthening or reconstruction, respectively. Steel roof
is composed of plane truss main girders, purlins and bracings and the
roof structure is supported by two arch main girders with the span of
L = 84 m. The in situ diagnostics of the roof structure was oriented to
the following parts: (i) determination and evaluation of the actual
material properties of used steel and (ii) verification of the actual
dimensions of the structural members. For the solution the nondestructive
methods have been used for in situ measurement. For the
indicative determination of steel strengths the modified method based
on the determination of Rockwell’s hardness has been used. For the
verification of the member’s dimensions (thickness of hollow
sections) the ultrasound method has been used. This paper presents
the results obtained using these testing methods and their evaluation,
from the viewpoint of the usage for the subsequent static assessment
and design evaluation of the existing structure. For the comparison,
the examples of the similar evaluations realized for steel structures of
the stadiums in Olomouc and Jihlava cities are briefly illustrated, too.
Abstract: Steel thin-walled beams have been widely used in civil engineering as purlins, ceiling beams or wall substructure beams. There are often planar members such as trapezoidal sheeting or sandwich panels used as roof or wall cladding fastened to the steel beams. The planar members also serve as stabilization of thin-walled beams against buckling due to loss of stability. This paper focuses on problem of stabilization of steel monosymmetric thin-walled beams by trapezoidal sheeting. Some factors having influence on overall behavior of this structural system are investigated using numerical analysis. Thin-walled beams in bending stabilized by trapezoidal sheeting are of primarily interest of this study.
Abstract: Superelastic Shape Memory Alloy (SMA) is accepted
when it used as connection in steel structures. The seismic behaviour
of steel frames with SMA is being assessed in this study. Three eightstorey
steel frames with different SMA systems are suggested, the
first one of which is braced with diagonal bracing system, the second
one is braced with nee bracing system while the last one is which the
SMA is used as connection at the plastic hinge regions of beams.
Nonlinear time history analyses of steel frames with SMA subjected
to two different ground motion records have been performed using
Seismostruct software. To evaluate the efficiency of suggested
systems, the dynamic responses of the frames were compared. From
the comparison results, it can be concluded that using SMA element
is an effective way to improve the dynamic response of structures
subjected to earthquake excitations. Implementing the SMA braces
can lead to a reduction in residual roof displacement. The shape
memory alloy is effective in reducing the maximum displacement at
the frame top and it provides a large elastic deformation range. SMA
connections are very effective in dissipating energy and reducing the
total input energy of the whole frame under severe seismic ground
motion. Using of the SMA connection system is more effective in
controlling the reaction forces at the base frame than other bracing
systems. Using SMA as bracing is more effective in reducing the
displacements. The efficiency of SMA is dependant on the input
wave motions and the construction system as well.
Abstract: In the present study the efficiency of Big Bang-Big
Crunch (BB-BC) algorithm is investigated in discrete structural
design optimization. It is shown that a standard version of the BB-BC
algorithm is sometimes unable to produce reasonable solutions to
problems from discrete structural design optimization. Two
reformulations of the algorithm, which are referred to as modified
BB-BC (MBB-BC) and exponential BB-BC (EBB-BC), are
introduced to enhance the capability of the standard algorithm in
locating good solutions for steel truss and frame type structures,
respectively. The performances of the proposed algorithms are
experimented and compared to its standard version as well as some
other algorithms over several practical design examples. In these
examples, steel structures are sized for minimum weight subject to
stress, stability and displacement limitations according to the
provisions of AISC-ASD.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes and kind of bracing (x and chevron bracing) have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: IPN and IPE sections, which are commonly used European I shapes, are widely used in steel structures as cantilever beams to support overhangs. A considerable number of studies exist on calculating lateral torsional buckling load of I sections. However, most of them provide series solutions or complex closed-form equations. In this paper, a simple equation is presented to calculate lateral torsional buckling load of IPN and IPE section cantilever beams. First, differential equation of lateral torsional buckling is solved numerically for various loading cases. Then a parametric study is conducted on results to present an equation for lateral torsional buckling load of European IPN and IPE beams. Finally, results obtained by presented equation are compared to differential equation solutions and finite element model results. ABAQUS software is utilized to generate finite element models of beams. It is seen that the results obtained from presented equation coincide with differential equation solutions and ABAQUS software results. It can be suggested that presented formula can be safely used to calculate critical lateral torsional buckling load of European IPN and IPE section cantilevers.