Abstract: Photoplethysmography is a simple measurement of the
variation in blood volume in tissue. It detects the pulse signal of heart
beat as well as the low frequency signal of vasoconstriction and
vasodilation. The transmission type measurement is limited to only a
few specific positions for example the index finger that have a short
path length for light. The reflectance type measurement can be
conveniently applied on most parts of the body surface. This study
analyzed the factors that determine the quality of reflectance
photoplethysmograph signal including the emitter-detector distance,
wavelength, light intensity, and optical properties of skin tissue.
Light emitting diodes (LEDs) with four different visible
wavelengths were used as the light emitters. A phototransistor was
used as the light detector. A micro translation stage adjusts the
emitter-detector distance from 2 mm to 15 mm.
The reflective photoplethysmograph signals were measured on
different sites. The optimal emitter-detector distance was chosen to
have a large dynamic range for low frequency drifting without signal
saturation and a high perfusion index. Among these four wavelengths,
a yellowish green (571nm) light with a proper emitter-detection
distance of 2mm is the most suitable for obtaining a steady and reliable
reflectance photoplethysmograph signal
Abstract: In this paper, an automated system is presented for
identification and separation of plastic resins based on near infrared
(NIR) reflectance spectroscopy. For identification and separation
among resins, a "Two-Filter" identification method is proposed that
is capable to distinguish among polyethylene terephthalate (PET),
high density polyethylene (HDPE), polyvinyl chloride (PVC),
polypropylene (PP) and polystyrene (PS). Through surveying effects
of parameters such as surface contamination, sample thickness, label
and cap existence, it was obvious that the "Two-Filter" method has a
high efficiency in identification of resins. It is shown that accurate
identification and separation of five major resins can be obtained
through calculating the relative reflectance at two wavelengths in the
NIR region.
Abstract: In this work we report on preliminary analysis of a novel optoelectronic gas sensor based on an optical fiber integrated with a tetrakis(4-sulfonatophenyl)porphyrin (TPPS) thin film. The sensitive materials are selectively deposited on the core region of a fiber tip by UV light induced deposition technique. A simple and cheap process which can be easily extended to different porphyrin derivatives. When the TPPS film on the fiber tip is exposed to acid and/or base vapors, dramatic changes occur in the aggregation structure of the dye molecules in the film, from J- to H-type, resulting in a profound modification of their corresponding reflectance spectra. From the achieved experimental results it is evident that the presence of intense and narrow band peaks in the reflected spectra could be monitored to detect hazardous vapors.
Abstract: Repeated observation of a given area over time yields
potential for many forms of change detection analysis. These
repeated observations are confounded in terms of radiometric
consistency due to changes in sensor calibration over time,
differences in illumination, observation angles and variation in
atmospheric effects.
This paper demonstrates applicability of an empirical relative
radiometric normalization method to a set of multitemporal cloudy
images acquired by Resourcesat1 LISS III sensor. Objective of this
study is to detect and remove cloud cover and normalize an image
radiometrically. Cloud detection is achieved by using Average
Brightness Threshold (ABT) algorithm. The detected cloud is
removed and replaced with data from another images of the same
area. After cloud removal, the proposed normalization method is
applied to reduce the radiometric influence caused by non surface
factors. This process identifies landscape elements whose reflectance
values are nearly constant over time, i.e. the subset of non-changing
pixels are identified using frequency based correlation technique. The
quality of radiometric normalization is statistically assessed by R2
value and mean square error (MSE) between each pair of analogous
band.
Abstract: We design and discuss metal-dielectric antireflection coating on metallic substrates for Solar Selective Absorbers of Concentrating Solar Power Systems. The average reflectance is 8.5% at 400-3000nm and 84.4% at 3000nm-10000nm of the metal-dielectric structure.
Abstract: The characterization of κ-carrageenan could provide a
better understanding of its functions in biological, medical and
industrial applications. Chemical and physical analyses of
carrageenan from seaweeds, Euchema cottonii L., were done to offer
information on its properties and the effects of Co-60 γ-irradiation on
its thermochemical characteristics. The structural and morphological
characteristics of κ-carrageenan were determined using scanning
electron microscopy (SEM) while the composition, molecular weight
and thermal properties were determined using attenuated total
reflectance Fourier transform infrared spectroscopy (ATR-FTIR), gel
permeation chromatography (GPC), thermal gravimetric analysis
(TGA) and differential scanning calorimetry (DSC). Further chemical
analysis was done using hydrogen-1 nuclear magnetic resonance (1H
NMR) and functional characteristics in terms of biocompatibility
were evaluated using cytotoxicity test.
Abstract: The use of solar control film on windows as one of
solar passive strategies for building have becoming important and is
gaining recognition. Malaysia located close to equator is having
warm humid climate with long sunshine hours and abundant solar
radiation throughout the year. Hence, befitting solar control on
windows is absolutely necessary to capture the daylight whilst
moderating thermal impact and eliminating glare problems. This is
one of the energy efficient strategies to achieve thermal and visual
comfort in buildings. Therefore, this study was carried out to
investigate the effect of window solar controls on thermal and visual
performance of naturally ventilated buildings. This was conducted via
field data monitoring using a test building facility. Four types of
window glazing systems were used with three types of solar control
films. Data were analysed for thermal and visual impact with
reference to thermal and optical characteristics of the films. Results
show that for each glazing system, the surface temperature of
windows are influenced by the Solar Energy Absorption property, the
indoor air temperature are influenced by the Solar Energy
Transmittance and Solar Energy Reflectance, and the daylighting by
Visible Light Transmission and Shading Coefficient. Further
investigations are underway to determine the mathematical relation
between thermal energy and visual performance with the thermal and
optical characteristics of solar control films.
Abstract: We developed an effective microfluidic device for photoreactions with low reflectance and good heat conductance. The performance of this microfluidic device was tested by carrying out a photoreactive synthesis of benzopinacol and acetone from benzophenone and 2-propanol. The yield reached 36% with an irradiation time of 469.2 s and was improved by more than 30% when compared to the values obtained by the batch method. Therefore, the microfluidic device was found to be effective for improving the yields of photoreactions.
Abstract: We derive simple sets of equations to describe the microwave response of a thin film of magnetized hydrogen plasma in the presence of carbon nanotubes, which were grown by ironcatalyzed high-pressure disproportionation (HiPco). By considering the interference effects due to multiple reflections between thin plasma film interfaces, we present the effects of the continuously changing external magnetic field and plasma parameters on the reflected power, absorbed power, and transmitted power in the system. The simulation results show that the interference effects play an important role in the reflectance, transmittance and absorptance of microwave radiation at the magnetized plasma slab. As a consequence, the interference effects lead to a sinusoidal variation of the reflected intensity and can greatly reduce the amount of reflection power, but the absorption power increases.
Abstract: Mechanical interaction between endothelial cells (ECs) and the extracellular matrix (or collagen gel) is known to influence the sprouting response of endothelial cells during angiogenesis. This influence is believed to impact on the capability of endothelial cells to sense soluble chemical cues. Quantitative analysis of endothelial-cell-mediated displacement of the collagen gel provides a means to explore this mechanical interaction. Existing analysis in this context is generally limited to 2D settings. In this paper, we investigate the mechanical interaction between endothelial cells and the extracellular matrix in terms of the endothelial-cellmediated displacement of the collagen gel in both 2D and 3D. Digital image correlation and Digital volume correlation are applied on confocal reflectance image stacks to analyze cell-mediated displacement of the gel. The skeleton of the sprout is extracted from phase contrast images and superimposed on the displacement field to further investigate the link between the development of the sprout and the displacement of the gel.
Abstract: The amplitude response of infrared (IR) sensors
depends on the reflectance properties of the target. Therefore, in
order to use IR sensor for measuring distances accurately, prior
knowledge of the surface must be known. This paper describes the
Phong Illumination Model for determining the properties of a surface
and subsequently calculating the distance to the surface. The angular
position of the IR sensor is computed as normal to the surface for
simplifying the calculation. Ultrasonic (US) sensor can provide the
initial information on distance to obtain the parameters for this
method. In addition, the experimental results obtained by using
LabView are discussed. More care should be taken when placing the
objects from the sensors during acquiring data since the small change
in angle could show very different distance than the actual one.
Since stereo camera vision systems do not perform well under some
environmental conditions such as plain wall, glass surfaces, or poor
lighting conditions, the IR and US sensors can be used additionally to
improve the overall vision systems of mobile robots.
Abstract: In this paper we evaluated the efficacy of
photodynamic treatment of infected wounds on pig animal model by
diffuse reflectance spectrometry. The study was conducted on fifteen
wounds contaminated with Staphylococcus aureus bacteria that were
incubated for 30 min with methylene blue solution (c = 3.3 x 10-3 M)
and exposed to laser radiations (λ = 670 nm, P = 15 mW) for 15 min.
The efficiency of photodynamic inactivation of bacteria was
evaluated by microbiological exams and diffuse reflectance
spectrometry. The results of the microbiological exams showed that
the bacterial concentration has decreased from 6.93±0.138
logCFU/ml to 3.12±0.108 logCFU/ml. The spectral examination
showed that the diffuse reflectance of wounds contaminated with
Staphylococcus aureus has decreased from 5.06±0.036 % to
3.36±0.025 %. In conclusion, photodynamic therapy is an effective
method for the treatment of infected wounds and there is a correlation
between the CFU count and diffuse reflectance.
Abstract: An optical fiber Fabry-Perot interferometer (FFPI) is
proposed and demonstrated for dynamic measurements in a
mechanical vibrating target. A polishing metal with a low reflectance
value adhered to a mechanical vibrator was excited via a function
generator at various excitation frequencies. Output interference
fringes were generated by modulating the reference and sensing
signal at the output arm. A fringe-counting technique was used for
interpreting the displacement information on the dedicated computer.
The fiber interferometer has been found the capability of the
displacement measurements of 1.28 μm – 96.01 μm. A commercial
displacement sensor was employed as a reference sensor for
investigating the measurement errors from the fiber sensor. A
maximum percentage measurement error of approximately 1.59 %
was obtained.
Abstract: In cancer progress, the optical properties of tissues
like absorption and scattering coefficient change, so by these
changes, we can trace the progress of cancer, even it can be applied
for pre-detection of cancer. In this paper, we investigate the effects of
changes of optical properties on light penetrated into tissues. The
diffusion equation is widely used to simulate light propagation into
biological tissues. In this study, the boundary integral method (BIM)
is used to solve the diffusion equation. We illustrate that the changes
of optical properties can modified the reflectance or penetrating light.
Abstract: In this work we study the reflection of circularly
polarised light from a nano-structured biological material found in
the exocuticle of scarabus beetles. This material is made of a stack
of ultra-thin (~5 nm) uniaxial layers arranged in a left-handed
helicoidal stack, which resonantly reflects circularly polarized light.
A chirp in the layer thickness combined with a finite absorption
coefficient produce a broad smooth reflectance spectrum. By
comparing model calculations and electron microscopy with
measured spectra we can explain our observations and quantify most
relevant structural parameters.
Abstract: Films of pure tin oxide SnO2 and in presence of
antimony atoms (SnO2-Sb) deposited onto glass substrates have
shown a sufficiently high energy gap to be transparent in the visible
region, a high electrical mobility and a carrier concentration which
displays a good electrical conductivity [1]. In this work, the effects of
polycrystalline silicon substrate on the optical properties of pure and
Sb doped tin oxide is investigated.
We used the APCVD (atmospheric pressure chemical vapour
deposition) technique, which is a low-cost and simple technique,
under nitrogen ambient, for growing this material. A series of SnO2
and SnO2-Sb have been deposited onto polycrystalline silicon
substrates with different contents of antimony atoms at the same
conditions of deposition (substrate temperature, flow oxygen,
duration and nitrogen atmosphere of the reactor). The effect of the
substrate in terms of morphology and nonlinear optical properties,
mainly the reflectance, was studied. The reflectance intensity of the
device, compared to the reflectance of tin oxide films deposited
directly on glass substrate, is clearly reduced on the overall
wavelength range. It is obvious that the roughness of the poly-c
silicon plays an important role by improving the reflectance and
hence the optical parameters.
A clear shift in the minimum of the reflectance upon doping level
is observed. This minimum corresponds to strong free carrier
absorption, resulting in different plasma frequency. This effect is
followed by an increase in the reflectance depending of the antimony
doping. Applying the extended Drude theory to the combining
optical and electrical obtained results these effects are discussed.
Abstract: This paper presents a low cost design of heart beat monitoring device using reflectance mode PhotoPlethysmography (PPG). PPG is known for its simple construction, ease of use and cost effectiveness and can provide information about the changes in cardiac activity as well as aid in earlier non-invasive diagnostics. The proposed device is divided into three phases. First is the detection of pulses through the fingertip. The signal is then passed to the signal processing unit for the purpose of amplification, filtering and digitizing. Finally the heart rate is calculated and displayed on the computer using parallel port interface. The paper is concluded with prototyping of the device followed by verification procedure of the heartbeat signal obtained in laboratory setting.
Abstract: To measure the thickness of the subcutaneous adipose
tissue layer, a non-invasive optical measurement system (λ=1300 nm)
is introduced. Animal and human subjects are used for the
experiments. The results of human subjects are compared with the data
of ultrasound device measurements, and a high correlation (r=0.94 for
n=11) is observed. There are two modes in the corresponding signals
measured by the optical system, which can be explained by
two-layered and three-layered tissue models. If the target tissue is
thinner than the critical thickness, detected data using diffuse
reflectance method follow the three-layered tissue model, so the data
increase as the thickness increases. On the other hand, if the target
tissue is thicker than the critical thickness, the data follow the
two-layered tissue model, so they decrease as the thickness increases.
Abstract: Determination of nano particle size is substantial since
the nano particle size exerts a significant effect on various properties
of nano materials. Accordingly, proposing non-destructive, accurate
and rapid techniques for this aim is of high interest. There are some
conventional techniques to investigate the morphology and grain size
of nano particles such as scanning electron microscopy (SEM),
atomic force microscopy (AFM) and X-ray diffractometry (XRD).
Vibrational spectroscopy is utilized to characterize different
compounds and applied for evaluation of the average particle size
based on relationship between particle size and near infrared spectra
[1,4] , but it has never been applied in quantitative morphological
analysis of nano materials. So far, the potential application of nearinfrared
(NIR) spectroscopy with its ability in rapid analysis of
powdered materials with minimal sample preparation, has been
suggested for particle size determination of powdered
pharmaceuticals. The relationship between particle size and diffuse
reflectance (DR) spectra in near infrared region has been applied to
introduce a method for estimation of particle size. Back propagation
artificial neural network (BP-ANN) as a nonlinear model was applied
to estimate average particle size based on near infrared diffuse
reflectance spectra. Thirty five different nano TiO2 samples with
different particle size were analyzed by DR-FTNIR spectrometry and
the obtained data were processed by BP- ANN.
Abstract: Semiconductor materials with coatings have a wide range of applications in MEMS and NEMS. This work uses transfermatrix method for calculating the radiative properties. Dopped silicon is used and the coherent formulation is applied. The Drude model for the optical constants of doped silicon is employed. Results showed that for the visible wavelengths, more emittance occurs in greater concentrations and the reflectance decreases as the concentration increases. In these wavelengths, transmittance is negligible. Donars and acceptors act similar in visible wavelengths. The effect of wave interference can be understood by plotting the spectral properties such as reflectance or transmittance of a thin dielectric film versus the film thickness and analyzing the oscillations of properties due to constructive and destructive interferences. But this effect has not been shown at visible wavelengths. At room temperature, the scattering process is dominated by lattice scattering for lightly doped silicon, and the impurity scattering becomes important for heavily doped silicon when the dopant concentration exceeds1018cm-3 .