Abstract: Ultra-high-performance fiber reinforced concrete (UHPFRC) is a specially formulated cement-based composite characterized with an ultra-high compressive strength (fc’ = 240 MPa) and a low water-cement ratio (W/B= 0.2). With such material characteristics, UHPFRC is favored for the design and constructions of structures required high structural performance and slender geometries. Unlike conventional concrete, the structural performance of members manufactured with UHPFRC has not yet been fully studied, particularly, for UHPFRC columns with high slenderness. In this study, the behaviors of slender UHPFRC columns under concentric or eccentric load will be investigated both experimentally and numerically. Four slender UHPFRC columns were tested under eccentric loads with eccentricities, of 0 mm, 35 mm, 50 mm, and 85 mm, respectively, and one UHPFRC beam was tested under four-point bending. Finite element (FE) analysis was conducted with concrete damage plasticity (CDP) modulus to simulating the load-middle height or middle span deflection relationships and damage patterns of all UHPFRC members. Simulated results were compared against the experimental results and observation to gain the confidence of FE model, and this model was further extended to conduct parametric studies, which aim to investigate the effects of slenderness regarding failure modes and load-moment interaction relationships. Experimental results showed that the load bearing capacities of the slender columns reduced with an increase in eccentricity. Comparisons between load-middle height and middle span deflection relationships as well as damage patterns of all UHPFRC members obtained both experimentally and numerically demonstrated high accuracy of the FE simulations. Based on the available FE model, the following parametric study indicated that a further increase in the slenderness of column resulted in significant decreases in the load-bearing capacities, ductility index, and flexural bending capacities.
Abstract: Since columns are the most important elements of the
structures, failure of one column in a critical location can cause a
progressive collapse. In this respect, the repair and strengthening of
columns is a very important subject to reduce the building failure and
to keep the columns capacity. Twenty columns with different
parameters is tested and analysis. Eleven typical confined reinforced
concrete (RC) columns with different types of techniques are
assessment. And also, four confined concrete columns with plastic
tube (PVC) are tested with and with four paralleling tested of
unconfined plain concrete. The techniques of confined RC columns
are mortar strengthening, Steel rings strengthening, FRP
strengthening. Moreover, the technique of confined plain concrete
(PC) column is used PVC tubes. The columns are tested under
uniaxial compressive loads studied the effect of confinement on the
structural behavior of circular RC columns. Test results for each
column are presented in the form of crack patterns, stress-strain
curves. Test results show that confining of the RC columns using
different techniques of strengthening results significant improvement
of the general behavior of the columns and can used in construction.
And also, tested confined PC columns with PVC tubes results shown
that the confined PC with PVC tubes can be used in economical
building. The theoretical model for predicted column capacity is
founded with experimental factor depends on the confined techniques
used and the strain reduction.
Abstract: This paper investigates the viability of using carbon
fiber reinforced epoxy composites modified with carbon nanotubes to
strengthening reinforced concrete (RC) columns. Six RC columns
was designed and constructed according to ASCE standards. The
columns were wrapped using carbon fiber sheets impregnated with
either neat epoxy or CNTs modified epoxy. These columns were then
tested under concentric axial loading. Test results show that;
compared to the unwrapped specimens; wrapping concrete columns
with carbon fiber sheet embedded in CNTs modified epoxy resulted
in an increase in its axial load resistance, maximum displacement,
and toughness values by 24%, 109% and 232%, respectively. These
results reveal that adding CNTs into epoxy resin enhanced the
confinement effect, specifically, increased the axial load resistance,
maximum displacement, and toughness values by 11%, 6%, and
19%, respectively compared with columns strengthening with carbon
fiber sheet embedded in neat epoxy.
Abstract: An experimental study of Reinforced Concrete, RC, columns strengthened using a steel jacketing technique was conducted. The jacketing technique consisted of four steel vertical angles installed at the corners of the column joined by horizontal steel straps confining the column externally. The effectiveness of the technique was evaluated by testing the RC column specimens under eccentric monotonic loading until failure occurred. Strain gauges were installed to monitor the strains in the internal reinforcement as well as the external jacketing system. The effectiveness of the jacketing technique was demonstrated, and the parameters affecting the technique were studied.
Abstract: This study was conducted published to investigate
there liability of the equation pressure-impulse (PI) reinforced
concrete column inprevious studies. Equation involves three different
levels of damage criteria known as D =0. 2, D =0. 5 and D =0. 8.The
damage criteria known as a minor when 0-0.2, 0.2-0.5is known as
moderate damage, high damage known as 0.5-0.8, and 0.8-1 of the
structure is considered a failure. In this study, two types of reliability
analyzes conducted. First, using pressure-impulse equation with
different parameters. The parameters involved are the concrete
strength, depth, width, and height column, the ratio of longitudinal
reinforcement and transverse reinforcement ratio. In the first analysis
of the reliability of this new equation is derived to improve the
previous equations. The second reliability analysis involves three
types of columns used to derive the PI curve diagram using the
derived equation to compare with the equation derived from other
researchers and graph minimum standoff versus weapon yield
Federal Emergency Management Agency (FEMA). The results
showed that the derived equation is more accurate with FEMA
standards than previous researchers.